Power Integrations Topswiltch系列集成回扫式稳压器IC能以较少针脚的小型封装提供出色的性能。对于最少针脚数的封装.此多功能针脚有多种用途.包括开/关控制及电压不足与过电压输入检测。其它封装类型包括L形针脚,也可实现此功能...Power Integrations Topswiltch系列集成回扫式稳压器IC能以较少针脚的小型封装提供出色的性能。对于最少针脚数的封装.此多功能针脚有多种用途.包括开/关控制及电压不足与过电压输入检测。其它封装类型包括L形针脚,也可实现此功能。其应用说明和数据表介绍了如何在这些针脚上实施各种可用的特性。例如.要允许远程开/关控制.并仍IR保持欠压与过压保护功能,展开更多
The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS)...The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.展开更多
The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inve...The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...展开更多
A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse c...A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.展开更多
Based on the high frequency and large signal discrete-time model for switching converters,a nonlinear discrete-time control method is designed on the principle of dynamic programming. In one switch period the optimal ...Based on the high frequency and large signal discrete-time model for switching converters,a nonlinear discrete-time control method is designed on the principle of dynamic programming. In one switch period the optimal duty ratio is got in accordance with a minimum error of the output voltage,then the duty ratio is checked and regulated with the energy function in order to make the global performance best. In thisway the complete objective function is obtained. Based on the objective function,the fast and accurate control effect is accomplished.展开更多
In order to realize the fault diagnosis of the control circuit of all-electronic computer interlocking system(ACIS)for railway signals,taking a five-wire switch electronic control module as an research object,we propo...In order to realize the fault diagnosis of the control circuit of all-electronic computer interlocking system(ACIS)for railway signals,taking a five-wire switch electronic control module as an research object,we propose a method of selecting the sample set of the basic classifier by roulette method and realizing fault diagnosis by using SVM-AdaBoost.The experimental results show that the proportion of basic classifier samples affects classification accuracy,which reaches the highest when the proportion is 85%.When selecting the sample set of basic classifier by roulette method,the fault diagnosis accuracy is generally higher than that of the maximum weight priority method.When the optimal proportion 85%is taken,the accuracy is highest up to 96.3%.More importantly,this way can better adapt to the critical data and improve the anti-interference ability of the algorithm,and therefore it provides a basis for fault diagnosis of ACIS.展开更多
A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The t...A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.展开更多
文摘The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.
文摘The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...
文摘A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.
文摘Based on the high frequency and large signal discrete-time model for switching converters,a nonlinear discrete-time control method is designed on the principle of dynamic programming. In one switch period the optimal duty ratio is got in accordance with a minimum error of the output voltage,then the duty ratio is checked and regulated with the energy function in order to make the global performance best. In thisway the complete objective function is obtained. Based on the objective function,the fast and accurate control effect is accomplished.
基金Natural Science Foundation of Gansu Province(Nos.18JR3RA130,2018C-11,2018A-022)Science Fund of Lanzhou Jiaotong University(No.2017022)。
文摘In order to realize the fault diagnosis of the control circuit of all-electronic computer interlocking system(ACIS)for railway signals,taking a five-wire switch electronic control module as an research object,we propose a method of selecting the sample set of the basic classifier by roulette method and realizing fault diagnosis by using SVM-AdaBoost.The experimental results show that the proportion of basic classifier samples affects classification accuracy,which reaches the highest when the proportion is 85%.When selecting the sample set of basic classifier by roulette method,the fault diagnosis accuracy is generally higher than that of the maximum weight priority method.When the optimal proportion 85%is taken,the accuracy is highest up to 96.3%.More importantly,this way can better adapt to the critical data and improve the anti-interference ability of the algorithm,and therefore it provides a basis for fault diagnosis of ACIS.
文摘A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.