In this paper, the evaluation of a preliminary design of a PGAA (prompt gamma activation analysis) facility based on Monte Carlo simulations is presented and discussed. The implementation of the PGAA method at the C...In this paper, the evaluation of a preliminary design of a PGAA (prompt gamma activation analysis) facility based on Monte Carlo simulations is presented and discussed. The implementation of the PGAA method at the CDTN (nuclear technology development centre) would increase the applications of the TRIGA reactor. The preliminary design is based on a quasi vertical hollow cylinder (called neutron extractor) in the reactor pool to extract the neutron flux. This study evaluates the neutron flux in the upper position of the cylinder in the suggested position of the samples to be analyzed by the PGAA. The calculations of the radioactive capture reaction rates and of the detection limits for some isotopes were performed. Through all these calculations, the feasibility of the application of the PGAA method at the IPR-R1 installations was evaluated. According to the obtained results, it can be concluded that is possible to apply the PGAA method at the IPR-R1 reactor, even with its design restrictions.展开更多
This paper presents results of PMMA (polymethylmethacrylate) dosimeters calibrations that are used as routine dosimeters in CDTN (Nuclear Technology Development Center) Gamma Irradiation Laboratory. The study was ...This paper presents results of PMMA (polymethylmethacrylate) dosimeters calibrations that are used as routine dosimeters in CDTN (Nuclear Technology Development Center) Gamma Irradiation Laboratory. The study was carried out within the framework of the Facility Quality Assurance Program with the purpose of to determine the calibration curve and accuracy of the Harwell Amber Perspex 3042 W dosimeters. The irradiations of the dosimeters were made in operational conditions of a Gamma lrradiator at CDTN, an R & D (research and development) institute connected to the CNEN (National Nuclear Energy Commission) (Brazil). The values for estimate of the expanded uncertainties achieved are typical of a routine dosimetry system.展开更多
This paper introduced the metal material database development and usage in car body design for automatic process. According to the common automotive steel product from the major steel plant in China and usage situatio...This paper introduced the metal material database development and usage in car body design for automatic process. According to the common automotive steel product from the major steel plant in China and usage situation in local automotive OEMs (original equipment manufacturers), a standard LS-DYNA material database contains 129 kinds of commonly used metal material and database is developed by CATARC. Considering the frequent use of material data and applied to different parts in FE model, engineers can save time with this standard tool and meet the future request of the automation modeling process.展开更多
文摘In this paper, the evaluation of a preliminary design of a PGAA (prompt gamma activation analysis) facility based on Monte Carlo simulations is presented and discussed. The implementation of the PGAA method at the CDTN (nuclear technology development centre) would increase the applications of the TRIGA reactor. The preliminary design is based on a quasi vertical hollow cylinder (called neutron extractor) in the reactor pool to extract the neutron flux. This study evaluates the neutron flux in the upper position of the cylinder in the suggested position of the samples to be analyzed by the PGAA. The calculations of the radioactive capture reaction rates and of the detection limits for some isotopes were performed. Through all these calculations, the feasibility of the application of the PGAA method at the IPR-R1 installations was evaluated. According to the obtained results, it can be concluded that is possible to apply the PGAA method at the IPR-R1 reactor, even with its design restrictions.
文摘This paper presents results of PMMA (polymethylmethacrylate) dosimeters calibrations that are used as routine dosimeters in CDTN (Nuclear Technology Development Center) Gamma Irradiation Laboratory. The study was carried out within the framework of the Facility Quality Assurance Program with the purpose of to determine the calibration curve and accuracy of the Harwell Amber Perspex 3042 W dosimeters. The irradiations of the dosimeters were made in operational conditions of a Gamma lrradiator at CDTN, an R & D (research and development) institute connected to the CNEN (National Nuclear Energy Commission) (Brazil). The values for estimate of the expanded uncertainties achieved are typical of a routine dosimetry system.
文摘This paper introduced the metal material database development and usage in car body design for automatic process. According to the common automotive steel product from the major steel plant in China and usage situation in local automotive OEMs (original equipment manufacturers), a standard LS-DYNA material database contains 129 kinds of commonly used metal material and database is developed by CATARC. Considering the frequent use of material data and applied to different parts in FE model, engineers can save time with this standard tool and meet the future request of the automation modeling process.