期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
变形纱线膨松性能的表征与EIB测试:2.工艺参数与膨松度的关系 被引量:10
1
作者 姜岩 翁小秋 +1 位作者 李东平 王善元 《纺织学报》 EI CAS CSCD 北大核心 2008年第2期25-28,共4页
为最终达到空气变形纱线及其多重变形纱线结构和性能设计的目标,对长丝原料及几个关键变形工艺参数进行了初步的单因子实验。结果显示,异收缩空气变形纱的膨松度可以通过选择单、复丝的线密度、空气变形加工和异收缩变形加工工艺参数的... 为最终达到空气变形纱线及其多重变形纱线结构和性能设计的目标,对长丝原料及几个关键变形工艺参数进行了初步的单因子实验。结果显示,异收缩空气变形纱的膨松度可以通过选择单、复丝的线密度、空气变形加工和异收缩变形加工工艺参数的方法加以有效控制。空气变形加工工艺参数中的超喂率和喂入方式,异收缩变形加工工艺参数中的异收缩率、平均收缩率对成纱的膨松性能有显著影响。 展开更多
关键词 收缩空气变形纱 膨松度 线密度 超喂率 异收缩率
下载PDF
A very high frequency index of heart rate variability for evaluation of left ventricular systolic function and prognosis in chronic heart failure patients using five-minute electrocardiogram
2
作者 Xia Liu 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2009年第4期213-217,共5页
Objective A novel index based on fi-equency-domain analysis of heart rate variability (HRV) was tested on patients with reduced left ventricular systolic function. This index, namely VHFI, was defined as the very hi... Objective A novel index based on fi-equency-domain analysis of heart rate variability (HRV) was tested on patients with reduced left ventricular systolic function. This index, namely VHFI, was defined as the very high frequency (VHF) component of the power spectrum normalized to represent its relative value in proportion to the total power minus the very low frequency component. Methods Patients (n = 130) were divided into a study group, consisting 66 patients with decreased left ventricular systolic function, and a control group, consisting 64 patients with normal heart structure and function and without severe coronary artery stenosis (〈 50%). Results VHFI in the study group was significantly higher than that in the control group (19.17 ± 13.35 vs 11.37 ± 10.77, P 〈 0.001). Cardiac events occurred in 18 patients during follow-up (33.34 i 3.26 months). Defining the positive test as VHFI =15 and negative test as VHFI 〈15, achieved a sensitivity of 57.58% and a specificity of78.13% for predicting decreased left ventricular systolic function, and achieved a sensitivity of 66.67% and a specificity of 64.29% for predicting cardiac events. Univariate Cox regression analysis showed that positive VHFI test was an independent variable in predictive cardiac events. Conclusions The results suggest that VHFI is a useful tool for quick evaluation of left ventricular systolic function and prediction of prognosis 展开更多
关键词 heart rate variability left ventricular systolic function PROGNOSIS chronic heart failure
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部