In this paper,two new concepts—“main out-of-step mode” and “minor out-of-step mode”—are proposed for power system reliability analysis. Large-scale power system studies found that out-of-step generator groups ma...In this paper,two new concepts—“main out-of-step mode” and “minor out-of-step mode”—are proposed for power system reliability analysis. Large-scale power system studies found that out-of-step generator groups may have characteristics of the main out-of-step mode and the minor out-of-step mode. The generator groups with main out-of-step modes can determine the out-of-step interface of the large-scale power system,while generators with the minor out-of-step modes cannot play such a role. Therefore,the method of capturing the out-of-step interface by seeking the lowest voltage point(the out-of-step center) can only group the generators with the main out-of-step modes,and may fail to combine the generators with the minor out-of-step modes into proper coherent generator groups. Thus,it is necessary in engineering applications to equip the generators that are likely to have the characteristics of the minor out-of-step modes with separation devices based on off-line simulation studies in order to reduce the risk of further accidents caused by these generators after system separation.展开更多
The effect of line voltage drop is considered larger on loads, especially on asynchronous motor, transformers and other non-linear load parameters in power system of large ships. A novel power flow method based on imp...The effect of line voltage drop is considered larger on loads, especially on asynchronous motor, transformers and other non-linear load parameters in power system of large ships. A novel power flow method based on improved node voltage method is proposed, and a typical ship power system, which has 2 power stations and 10 nodes, with closed-loop design but open-loop operation, is taken as an example. Simulation results show that the improved power flow calculation method has achieved higher accuracy and better convergence.展开更多
基金Project (No. 50277034) supported by the National Natural ScienceFoundation of China
文摘In this paper,two new concepts—“main out-of-step mode” and “minor out-of-step mode”—are proposed for power system reliability analysis. Large-scale power system studies found that out-of-step generator groups may have characteristics of the main out-of-step mode and the minor out-of-step mode. The generator groups with main out-of-step modes can determine the out-of-step interface of the large-scale power system,while generators with the minor out-of-step modes cannot play such a role. Therefore,the method of capturing the out-of-step interface by seeking the lowest voltage point(the out-of-step center) can only group the generators with the main out-of-step modes,and may fail to combine the generators with the minor out-of-step modes into proper coherent generator groups. Thus,it is necessary in engineering applications to equip the generators that are likely to have the characteristics of the minor out-of-step modes with separation devices based on off-line simulation studies in order to reduce the risk of further accidents caused by these generators after system separation.
基金Supported by the National Natural Science Foundation under Grant No. 60704004
文摘The effect of line voltage drop is considered larger on loads, especially on asynchronous motor, transformers and other non-linear load parameters in power system of large ships. A novel power flow method based on improved node voltage method is proposed, and a typical ship power system, which has 2 power stations and 10 nodes, with closed-loop design but open-loop operation, is taken as an example. Simulation results show that the improved power flow calculation method has achieved higher accuracy and better convergence.