Equal channel angular pressing(ECAP)is one of the most effective processes to produce ultra-fine grain(UFG)and nanocrystalline(NC)materials.Because the commercially pure titanium exhibits excellent biocompatibility pr...Equal channel angular pressing(ECAP)is one of the most effective processes to produce ultra-fine grain(UFG)and nanocrystalline(NC)materials.Because the commercially pure titanium exhibits excellent biocompatibility properties,it has a significant potential to be utilized as an implant material.The low static and dynamic strengths of the pure titanium are one of the weaknesses of this material.This defect can be removed by applying the ECAP process on the pure titanium.In this work,the commercially pure titanium Grade2(CP-Ti of Grade2)was pressed at room temperature by the ECAP process via a channel angle of135°for3passes.The microstructural analysis and mechanical tests such as tensile test,hardness test,three-point bending test and Charpy impact test were all carried out on the ECAPed CP-Ti through3passes.The microstructural evolution reveals that by applying the ECAP process,coarse grain(CG)structure develops to UFG/NC structure.Moreover,the results of the mechanical tests show that the process significantly increases the yield and ultimate tensile strengths,bending strength,hardness and fracture toughness of the commercially pure titanium so that it can be used as a replacement for metallic alloys used as biomaterials.展开更多
A nonlinear numerical model was developed to analyze reinforced concrete columns under combined axial load and bending up to failure. Results of reinforced concrete columns under eccentric compression tested to failur...A nonlinear numerical model was developed to analyze reinforced concrete columns under combined axial load and bending up to failure. Results of reinforced concrete columns under eccentric compression tested to failure are presented and compared to results from a numerical nonlinear model. The tests involved 10 columns with cross-section of 250 mm × 120 mm, geometrical reinforcement ratio of 1.57% and concrete with compression strength around 40 MPa, with 3,000 mm in length. The main variable was the load eccentricity in the direction of the smaller dimension of cross-section. Experimental results of ultimate load and of the evolution of transverse displacements and concrete strains are compared with the numerical results. The estimated results obtained by the numerical model are close to the experimental ones, being suitable for use in verification of elements under combined axial load and bending.展开更多
文摘Equal channel angular pressing(ECAP)is one of the most effective processes to produce ultra-fine grain(UFG)and nanocrystalline(NC)materials.Because the commercially pure titanium exhibits excellent biocompatibility properties,it has a significant potential to be utilized as an implant material.The low static and dynamic strengths of the pure titanium are one of the weaknesses of this material.This defect can be removed by applying the ECAP process on the pure titanium.In this work,the commercially pure titanium Grade2(CP-Ti of Grade2)was pressed at room temperature by the ECAP process via a channel angle of135°for3passes.The microstructural analysis and mechanical tests such as tensile test,hardness test,three-point bending test and Charpy impact test were all carried out on the ECAPed CP-Ti through3passes.The microstructural evolution reveals that by applying the ECAP process,coarse grain(CG)structure develops to UFG/NC structure.Moreover,the results of the mechanical tests show that the process significantly increases the yield and ultimate tensile strengths,bending strength,hardness and fracture toughness of the commercially pure titanium so that it can be used as a replacement for metallic alloys used as biomaterials.
文摘A nonlinear numerical model was developed to analyze reinforced concrete columns under combined axial load and bending up to failure. Results of reinforced concrete columns under eccentric compression tested to failure are presented and compared to results from a numerical nonlinear model. The tests involved 10 columns with cross-section of 250 mm × 120 mm, geometrical reinforcement ratio of 1.57% and concrete with compression strength around 40 MPa, with 3,000 mm in length. The main variable was the load eccentricity in the direction of the smaller dimension of cross-section. Experimental results of ultimate load and of the evolution of transverse displacements and concrete strains are compared with the numerical results. The estimated results obtained by the numerical model are close to the experimental ones, being suitable for use in verification of elements under combined axial load and bending.