We carried out a wind tunnel test to measure cladding loads for a high-rise building of 295 m in height, which would be located in the business center of Chongqing Municipality, P. R. China. The rigid model was used t...We carried out a wind tunnel test to measure cladding loads for a high-rise building of 295 m in height, which would be located in the business center of Chongqing Municipality, P. R. China. The rigid model was used to determine fluctuating local pressures on the exterior surfaces of the building. The wind tunnel test results show the cr/tical zone of wind pressures on building surfaces in both standalone and interference conditions. The computational fluid dynamics (CFD) was conducted by using the FLUENT Code to compare with the wind tunnel test results, and the steady three-dimensional turbulent flow with Realizable k-ε as a turbulence model was used. The CFD results are agree with the wind tunnel test results in regards to distributions of wind pressures over a high-rise building's surfaces.展开更多
To analyze the stability of a shallow square tunnel, a new curved failure mechanism, representing the mechanical characteristics and collapsing form of this type of tunnel, is constructed. Based on the upper bound the...To analyze the stability of a shallow square tunnel, a new curved failure mechanism, representing the mechanical characteristics and collapsing form of this type of tunnel, is constructed. Based on the upper bound theorem of limit analysis and the Hoek-Brown nonlinear failure criterion, the supporting pressure derived from the virtual work rate equation is regarded as an objective function to achieve optimal calculation. By employing variational calculation to optimize the objective function, an upper bound solution for the supporting pressure and the collapsing block shape of a shallow square tunnel are obtained. To evaluate the validity of the failure mechanism proposed in this paper, the solutions computed by the curved failure mechanism are compared with the results calculated by the linear multiple blocks failure mechanism when the Hoek-Brown nonlinear failure criterion is converted into the Mohr-Coulomb linear criterion. The influences of rock mass parameters on the supporting pressure and collapsing block shape are discussed.展开更多
基金Funded by the National Natural Science Foundation of China(No.90715024)
文摘We carried out a wind tunnel test to measure cladding loads for a high-rise building of 295 m in height, which would be located in the business center of Chongqing Municipality, P. R. China. The rigid model was used to determine fluctuating local pressures on the exterior surfaces of the building. The wind tunnel test results show the cr/tical zone of wind pressures on building surfaces in both standalone and interference conditions. The computational fluid dynamics (CFD) was conducted by using the FLUENT Code to compare with the wind tunnel test results, and the steady three-dimensional turbulent flow with Realizable k-ε as a turbulence model was used. The CFD results are agree with the wind tunnel test results in regards to distributions of wind pressures over a high-rise building's surfaces.
基金supported by the National Natural Science Foundation of China (No. 51178468)the National Basic Research Program (973) of China (No. 2011CB013800)
文摘To analyze the stability of a shallow square tunnel, a new curved failure mechanism, representing the mechanical characteristics and collapsing form of this type of tunnel, is constructed. Based on the upper bound theorem of limit analysis and the Hoek-Brown nonlinear failure criterion, the supporting pressure derived from the virtual work rate equation is regarded as an objective function to achieve optimal calculation. By employing variational calculation to optimize the objective function, an upper bound solution for the supporting pressure and the collapsing block shape of a shallow square tunnel are obtained. To evaluate the validity of the failure mechanism proposed in this paper, the solutions computed by the curved failure mechanism are compared with the results calculated by the linear multiple blocks failure mechanism when the Hoek-Brown nonlinear failure criterion is converted into the Mohr-Coulomb linear criterion. The influences of rock mass parameters on the supporting pressure and collapsing block shape are discussed.