唐山曹妃甸工业区装备制造基地的地基处理
1
作者 徐宝喜 《矿产勘查》 2009年第6期21-25,共5页
文章介绍曹妃甸工业区装备制造基地在吹填土地质上进行的地基处理。沙质地基进行简单的强降排水作业后,再经过3~5天的沙坑静压力消散,可以直接进行强夯作业。在含水量大的淤泥地区以及有较丰富地下水的粘性土、粉土软弱地基,若单采用强... 文章介绍曹妃甸工业区装备制造基地在吹填土地质上进行的地基处理。沙质地基进行简单的强降排水作业后,再经过3~5天的沙坑静压力消散,可以直接进行强夯作业。在含水量大的淤泥地区以及有较丰富地下水的粘性土、粉土软弱地基,若单采用强夯,土体中地下水的渗透性小,难以及时排除,必然会造成土体内存在有较大的水压力,致使强夯效果不明显。因此,在强夯之前必须首先采取适当措施降低地下水位。高真空排水可以用来有效地完成排水工作。文章以唐山曹妃甸工业区装备制造基地工程为例,对明沟排水、强降排水、高真空排水及强夯的施工工艺作简要说明。 展开更多
关键词 明沟排水 强降排水 高真空排水 强夯
下载PDF
A Field Test of All-Weather Surfaces for Horse Paddocks
2
作者 Hans E. von Wachenfelt 《Journal of Food Science and Engineering》 2016年第4期197-211,共15页
This field study sought to determine the all-weather surface construction providing the least contaminated runoff and drainage effluent when exposed to moderate to heavy precipitation and different manure loads in hor... This field study sought to determine the all-weather surface construction providing the least contaminated runoff and drainage effluent when exposed to moderate to heavy precipitation and different manure loads in horse paddocks during wintertime. Two different combinations of non-woven and woven geotextile together with two gravel fractions of 200 nlm were exposed to precipitation and horse manure/urine for two years under two manure regimes (manure removal and manure accumulation). In a simulated rainfall (SR) study, the test areas were also exposed to 50 mm precipitation for 30 min and 15 kg of horse manure under the two manure regimes. Runoff, drainage effluent and leachate flow were measured and sampled for both regimes. The geotextile-gravel construction reduced runoff and drained the test area throughout the two-year period, confirming construction stability and a dry walking surface area at a mean drain flow of 3.65 L m2 h1. The concentrations of total N, total phosphorus (TP), chemical oxygen demand (COD) and total solids (TS) in fluids leaving the test areas in winter were lower than in previous studies, due to lower horse density. The mean drainage concentration of TP, COD and TS was 3.4, 231, 739 mg L1, respectively, due to manure removal in the SR study. The TP (1.9 mg L-1) concentration in drain fluids was reduced by 47% in the test area consisting of a single geotextile compared with previously reported values (3.6 mg Ll). With the paddock designs tested here, non-point pollution from paddocks could be controlled and reduced. 展开更多
关键词 GEOTEXTILE HORSE MANURE RUNOFF drain leachate.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部