饱和塔循环热水量微机寻优
1
作者 王长生 宁良智 《化工自动化及仪表》 CAS 北大核心 1989年第4期15-18,共4页
饱和热水塔是一个重要的节能设备,为了充分发挥其节能功能,对我厂的678工段饱和热水塔的循环热水量采用微机寻优,使在最佳的循环热水量时,达到最好的节能效果。
关键词 饱和塔 循环热水量 寻优 合成氨
下载PDF
饱和塔循环热水量微机寻优
2
作者 王长生 宁良智 《中氮肥》 1990年第2期82-85,共4页
我厂净化车间的饱和热水塔回收本工段的热量产蒸汽自用,以减少外供蒸汽,降低能耗。为了进一步发挥饱和热水塔的节能功能,我们设想对饱和塔的循环热水量采用微机寻优,达到最好的节能效果。1.局部工艺过程饱和热水塔系统的工艺流程如图1... 我厂净化车间的饱和热水塔回收本工段的热量产蒸汽自用,以减少外供蒸汽,降低能耗。为了进一步发挥饱和热水塔的节能功能,我们设想对饱和塔的循环热水量采用微机寻优,达到最好的节能效果。1.局部工艺过程饱和热水塔系统的工艺流程如图1所示。压缩三段来的半水煤气〔压力 P_1为2.0MPa,流量 G_(1-2)12000~24000Nm^3/h(正常情况为24000Nm^3/h),温度 T_(1-1)为60℃左右〕进入饱和塔底部。 展开更多
关键词 化肥 饱和水塔 循环热水量 微机
下载PDF
Crawlspace heating system in detached house with insulated foundation
3
作者 刘青荣 阮应君 +1 位作者 RYU Yu-ji 任建兴 《Journal of Central South University》 SCIE EI CAS 2012年第3期623-632,共10页
Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Bas... Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation sol, ware, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20℃. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively. 展开更多
关键词 erawlspaee heating system indoor thermal environment detached house floor insulation foundation insulation
下载PDF
Experimental study of the flow and heat transfer of a gas–water mixture through a packed channel 被引量:1
4
作者 Xiaolei Zhu Xiaofeng Sui +2 位作者 Yan Zhao Ji'an Meng Zhixin Li 《Science Bulletin》 SCIE EI CAS CSCD 2016年第5期406-415,共10页
Waste heat recovery from the flue gas of gasfired boilers was studied experimentally by measuring the flow and heat transfer of air and water through six kinds of packing with saturated humid air as the simulated flue... Waste heat recovery from the flue gas of gasfired boilers was studied experimentally by measuring the flow and heat transfer of air and water through six kinds of packing with saturated humid air as the simulated flue gas.The experiments measured the effects of inlet air temperature, inlet air velocity and circulating water flow rate on the flow and heat transfer. The results show that higher inlet air temperatures and lower inlet air velocities lower the flow resistance and increase the heat transfer coefficient. The stainless steel packing had better surface wettability and larger thermal conductivity than the plastic packing, which enhanced the heat transfer between the water and the saturated moist air. When both the flow resistance reduction and the heat transfer enhancement were considered, the experimental results gave an optimal packing-specific surface area. A packed heat exchanger tower was designed for waste heat recovery from the flue gas of gas-fired boilers based on the experimental results which had better flow and heat transfer characteristics with lower pump and fan power consumption, more stable system operation and less thermal fluctuations compared with a non-packed heat transfer system with atomized water. 展开更多
关键词 Flue gas waste heat recovery Flow and heat transfer Moist air Packed heat exchanger tower