A new method of the modifying factor for determining the broadband complex permeability of magnetic thin films,was proposed. Based on the measurement technology of shot-end microstrip line and the new modify factor,a ...A new method of the modifying factor for determining the broadband complex permeability of magnetic thin films,was proposed. Based on the measurement technology of shot-end microstrip line and the new modify factor,a series of FeCo-based magnetic thin films deposited on the oxidized silicon substrates and with an in-plane uniaxial anisotropy were measured in the frequency range of 0.5-5 GHz. The results fit well with the Landau-Lifchitz-Gilbert theory in a broad frequency range.展开更多
A novel technique for the quick measurement moisture content of coal powder by microwave was studied. The effects of the various moisture contents on the measurement results were also discussed. The experimental resul...A novel technique for the quick measurement moisture content of coal powder by microwave was studied. The effects of the various moisture contents on the measurement results were also discussed. The experimental results show that the standard deviation is less than 0.36% when the moisture content of coal powder is 0.74%-16.90% and the standard deviation is less than 0.16% when the moisture content is 0.31%-1.49%. The experimental results indicate that a process of quick measurement moisture content of coal powder by microwave is practical.展开更多
The sensitive second derivative waves of Cu(Ⅱ),Pb(Ⅱ),Cd(Ⅱ),Ni(Ⅱ),Zn(Ⅱ),Fe(Ⅱ)and Mn(Ⅱ),forming in the substrate solution(pH=9.26)consisting of ammonia,ammonium chlorid,gelatin and ascorbic acid were researched.T...The sensitive second derivative waves of Cu(Ⅱ),Pb(Ⅱ),Cd(Ⅱ),Ni(Ⅱ),Zn(Ⅱ),Fe(Ⅱ)and Mn(Ⅱ),forming in the substrate solution(pH=9.26)consisting of ammonia,ammonium chlorid,gelatin and ascorbic acid were researched.The peak potentials of the polarographic waves of the seven ions are at about 0.48,0.63,0.79,1.04,1.28,1.44 and 1.60 V respectively.Combining with microwave technique,a new method for the simultaneous determination of the seven trace elements in Chinese traditional medicine was developed.The method is easy to operate,rapid,simple and convenient.When the signal-to-noise rate equals 3,the detection limits of Cu,Pb,Cd,Ni,Zn,Fe and Mn are 4.2×10 3,5.3×10 3,2.1×10 3,5.8×10 4,3.0×10 3,7.7×10 4 and 1.1×10 3 μg/mL respectively.Well linear relationships exist between the concentrations and the peak currents when Cu,Pb,Cd,Ni,Zn,Fe and Mn concentrations are within 8.5×10 3 10,9.7×10 3 10,4.5×10 3 10,1.2×10 3 10,6.4×10 3 10,1.5×10 3 10 and 2.8×10 3 10 μg/mL,respectively.The method has been used to the simultaneous determination of the seven trace elements in Salvia Miltiorrhiza Root and compound Salvia Miltiorrhiza Root injection,the relative standard deviations(RSDs)of the Cu,Pb,Cd,Ni,Zn,Fe and Mn in the two medicines are 3.9% and 5.8%,4.0% and 4.1%,4.3% and 5.7%,4.9% and 5.3%,4.4% and 4.7%,3.5% and 4.0%,0.51% and 2.8%,respectively;the comparisons of the determination results with the values obtained by the standard method indicate that the presented method has very well veracity.展开更多
This paper investigates a microwave heating method for the determination of chemical oxygen demand (COD) in seawater. The influences of microwave-power, heating time and standard substances on the results are studied....This paper investigates a microwave heating method for the determination of chemical oxygen demand (COD) in seawater. The influences of microwave-power, heating time and standard substances on the results are studied. Using the proposed method, we analyzed the glucose standard solution, the coefficient of variation being less than 2%. Compared with the traditional electric stove heating method, the results of F-test and T-test showed that there was no significant difference between the two methods, but the microwave method had slightly higher precision and reproducibility than the electric stove method. With the microwave heating method, several seawater samples from Jiaozhou Bay and the South Yellow Sea were also analyzed. The recovery was between 97.5% and 104.3%. This new method has the advantages of shortening the heating time, improving the working efficiency and having simple operation and therefore can be used to analyze the COD in seawater.展开更多
基金Project(50771047) supported by the National Natural Science Foundation of ChinaProject(NCET-04-0702) supported by the New Century Excellent Talents in University, ChinaProject(2005ABB002) supported by the Elitist in Natural Science Foundation of Hubei Province
文摘A new method of the modifying factor for determining the broadband complex permeability of magnetic thin films,was proposed. Based on the measurement technology of shot-end microstrip line and the new modify factor,a series of FeCo-based magnetic thin films deposited on the oxidized silicon substrates and with an in-plane uniaxial anisotropy were measured in the frequency range of 0.5-5 GHz. The results fit well with the Landau-Lifchitz-Gilbert theory in a broad frequency range.
文摘A novel technique for the quick measurement moisture content of coal powder by microwave was studied. The effects of the various moisture contents on the measurement results were also discussed. The experimental results show that the standard deviation is less than 0.36% when the moisture content of coal powder is 0.74%-16.90% and the standard deviation is less than 0.16% when the moisture content is 0.31%-1.49%. The experimental results indicate that a process of quick measurement moisture content of coal powder by microwave is practical.
基金Proejcr(20235020) supported by the National Natural Science Foundation of China
文摘The sensitive second derivative waves of Cu(Ⅱ),Pb(Ⅱ),Cd(Ⅱ),Ni(Ⅱ),Zn(Ⅱ),Fe(Ⅱ)and Mn(Ⅱ),forming in the substrate solution(pH=9.26)consisting of ammonia,ammonium chlorid,gelatin and ascorbic acid were researched.The peak potentials of the polarographic waves of the seven ions are at about 0.48,0.63,0.79,1.04,1.28,1.44 and 1.60 V respectively.Combining with microwave technique,a new method for the simultaneous determination of the seven trace elements in Chinese traditional medicine was developed.The method is easy to operate,rapid,simple and convenient.When the signal-to-noise rate equals 3,the detection limits of Cu,Pb,Cd,Ni,Zn,Fe and Mn are 4.2×10 3,5.3×10 3,2.1×10 3,5.8×10 4,3.0×10 3,7.7×10 4 and 1.1×10 3 μg/mL respectively.Well linear relationships exist between the concentrations and the peak currents when Cu,Pb,Cd,Ni,Zn,Fe and Mn concentrations are within 8.5×10 3 10,9.7×10 3 10,4.5×10 3 10,1.2×10 3 10,6.4×10 3 10,1.5×10 3 10 and 2.8×10 3 10 μg/mL,respectively.The method has been used to the simultaneous determination of the seven trace elements in Salvia Miltiorrhiza Root and compound Salvia Miltiorrhiza Root injection,the relative standard deviations(RSDs)of the Cu,Pb,Cd,Ni,Zn,Fe and Mn in the two medicines are 3.9% and 5.8%,4.0% and 4.1%,4.3% and 5.7%,4.9% and 5.3%,4.4% and 4.7%,3.5% and 4.0%,0.51% and 2.8%,respectively;the comparisons of the determination results with the values obtained by the standard method indicate that the presented method has very well veracity.
文摘This paper investigates a microwave heating method for the determination of chemical oxygen demand (COD) in seawater. The influences of microwave-power, heating time and standard substances on the results are studied. Using the proposed method, we analyzed the glucose standard solution, the coefficient of variation being less than 2%. Compared with the traditional electric stove heating method, the results of F-test and T-test showed that there was no significant difference between the two methods, but the microwave method had slightly higher precision and reproducibility than the electric stove method. With the microwave heating method, several seawater samples from Jiaozhou Bay and the South Yellow Sea were also analyzed. The recovery was between 97.5% and 104.3%. This new method has the advantages of shortening the heating time, improving the working efficiency and having simple operation and therefore can be used to analyze the COD in seawater.