应用 FJ-1型复合波经络治疗仪治疗冠心病 32例,取得了显著的临床疗效,有效率 96,89%.实验证明,循经感传气至病所过程 P 波峰值呈双向调整,Ⅱ导、F导、V_3导联峰值呈正性调整.时值以延长为主,循经感传改善了心肌代谢,增强了机体的保护性...应用 FJ-1型复合波经络治疗仪治疗冠心病 32例,取得了显著的临床疗效,有效率 96,89%.实验证明,循经感传气至病所过程 P 波峰值呈双向调整,Ⅱ导、F导、V_3导联峰值呈正性调整.时值以延长为主,循经感传改善了心肌代谢,增强了机体的保护性适应机能.同时对人体的电活动调向了新平衡.循经感传对心电 P 波的作用是其调控阴阳的重要过程.展开更多
AIM:To investigate the P wave dispersion as a non-invasive marker of intra-atrial conduction disturbances in patients with Wilson's disease. METHODS:We compared Wilson's disease patients (n = 18) with age matc...AIM:To investigate the P wave dispersion as a non-invasive marker of intra-atrial conduction disturbances in patients with Wilson's disease. METHODS:We compared Wilson's disease patients (n = 18) with age matched healthy subjects (n = 15) as controls. The diagnosis was based on clinical symptoms, laboratory tests (ceruloplasmin, urinary and hepatic copper concentrations). P wave dispersion, a measurement of the heterogeneity of atrial depolarization, was measured as the difference between the duration of the longest and the shortest P-waves in 12 lead electrocardiography. RESULTS:All the patients were asymptomatic on cardiological examination and have sinusal rhythm in electrocardiography. Left ventricular and left atrial diameters, left ventricular ejection fraction and left ventricular mass index were similar in both groups. The Wilson's disease patients had a significantly higher P wave dispersion compared with the controls (44.7 ± 5.8 vs 25.7 ± 2.5, P < 0.01). CONCLUSION:There was an increase in P wave dispersion in cardiologically asymptomatic Wilson's disease patients which probably represents an early stage of cardiac involvement.展开更多
The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of tra...The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of transcatheter aortic valve replacement (TAVR) procedure on atrial electrical remodeling. In this study, TAVR procedure led to a decrease on P-wave duration and P-wave dinner,inn展开更多
文摘应用 FJ-1型复合波经络治疗仪治疗冠心病 32例,取得了显著的临床疗效,有效率 96,89%.实验证明,循经感传气至病所过程 P 波峰值呈双向调整,Ⅱ导、F导、V_3导联峰值呈正性调整.时值以延长为主,循经感传改善了心肌代谢,增强了机体的保护性适应机能.同时对人体的电活动调向了新平衡.循经感传对心电 P 波的作用是其调控阴阳的重要过程.
文摘AIM:To investigate the P wave dispersion as a non-invasive marker of intra-atrial conduction disturbances in patients with Wilson's disease. METHODS:We compared Wilson's disease patients (n = 18) with age matched healthy subjects (n = 15) as controls. The diagnosis was based on clinical symptoms, laboratory tests (ceruloplasmin, urinary and hepatic copper concentrations). P wave dispersion, a measurement of the heterogeneity of atrial depolarization, was measured as the difference between the duration of the longest and the shortest P-waves in 12 lead electrocardiography. RESULTS:All the patients were asymptomatic on cardiological examination and have sinusal rhythm in electrocardiography. Left ventricular and left atrial diameters, left ventricular ejection fraction and left ventricular mass index were similar in both groups. The Wilson's disease patients had a significantly higher P wave dispersion compared with the controls (44.7 ± 5.8 vs 25.7 ± 2.5, P < 0.01). CONCLUSION:There was an increase in P wave dispersion in cardiologically asymptomatic Wilson's disease patients which probably represents an early stage of cardiac involvement.
文摘The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of transcatheter aortic valve replacement (TAVR) procedure on atrial electrical remodeling. In this study, TAVR procedure led to a decrease on P-wave duration and P-wave dinner,inn