用于心磁传感器测试系统的三轴向亥姆赫兹线圈的设计与仿真 被引量:1
1
作者 刘仲思 杨建中 +2 位作者 张帆 李滨 陈湾湾 《工程设计学报》 CSCD 北大核心 2019年第2期230-236,共7页
心磁检测对于心脏相关疾病的诊断具有独特优势,在用于测量心脏磁场的传感器(下称心磁传感器)的研制过程中,需要在模拟心磁的磁场环境下进行测试工作。基于此,设计了一个用于心磁传感器测试系统的亥姆赫兹线圈,它可以产生磁感应强度为pT... 心磁检测对于心脏相关疾病的诊断具有独特优势,在用于测量心脏磁场的传感器(下称心磁传感器)的研制过程中,需要在模拟心磁的磁场环境下进行测试工作。基于此,设计了一个用于心磁传感器测试系统的亥姆赫兹线圈,它可以产生磁感应强度为pT级的动态磁场,模拟心磁环境,以满足心磁传感器测试的需求。根据亥姆赫兹线圈的磁场产生原理,使用磁屏蔽筒对环境磁场进行屏蔽,通过计算确定了线圈尺寸、线圈匝数、导线长度及导线横截面直径等参数。使用COMSOL Multiphysics仿真软件对亥姆赫兹线圈产生的静态磁场的分布均匀性以及通入线圈电流变化时磁场的动态特性进行仿真分析。仿真结果表明,所设计的亥姆赫兹线圈满足设计要求,能够产生磁场强度为100 pT左右、均匀度小于5%、波形实时性好的类心脏磁场波形,为心磁传感器的测试提供了良好的测试环境。所设计的亥姆赫兹线圈能够用于心磁传感器的测试工作,为心磁传感器的实际应用奠定了基础。 展开更多
关键词 亥姆赫兹线圈 心磁传感器 场仿真
下载PDF
Accuracy of three-dimensional quantification of left ventricular function using magnetic sensor acquisition: a dynamic in vitro model
2
作者 徐金峰 吴瑛 +5 位作者 李小葵 Ghada Elsedfy 李军 Jongsoo Lee Grispin H Davies David J Sahn 《Chinese Medical Journal》 SCIE CAS CSCD 2001年第10期3-6,101,共5页
Objective To evaluate the accuracy of a three-dimensional (3D) magnetic position sensor system in the quantification of ventricular stroke volumes in a dynamic model.Methods A latex balloon model of the left ventricle... Objective To evaluate the accuracy of a three-dimensional (3D) magnetic position sensor system in the quantification of ventricular stroke volumes in a dynamic model.Methods A latex balloon model of the left ventricle was suspended in a water bath connected to a pump producing 10 different pulsatile stroke volumes (15-65mi/beat). Scanning was performed using a 5.0 mHz transducer mounted with a Flock of Birds (FOB) magnetic receiver (GE System Five). The probe was scanned to sweep continuously across and over the balloon volume over 3 - 7 seconds. Digital loops were stored on magneto-optical disks and reviewed retrospectively using 3D Echopac software (GE)based on Simpson's method and compared with a two-dimensional (2D) biplane area-length method (1/2L x R) measurements at end systole and end diastole. Both 3D and 2D derived stroke volumes were compared with the reference stroke volume calculated by direct measurement of balloon capacity.Results There was an improved correlation between 3D stroke volume and reference stroke volume ( y = 0.91 x + 0.41, r = 0.97, SEE = 2.83 ml, P = 0.0001 ) compared to 2D stroke volume and reference stroke volume (y=0.49x+8.68, r=0.87, SEE=3.87 ml, P=0.0011, difference between 2D and 3D P<0.003).Conclusion 3D magnetic FOB scanning is practical, accurate and should facilitate assessment of left ventricular function. 展开更多
关键词 three dimensional echocardiography · left ventricular function · magnetic sensor
原文传递