Different contents of biodiesel and petrodiesel were incorporated into diesel engine oils. The oxidative stability, detergency and antiwear performance of the formulated diesel oils were evaluated. The results indicat...Different contents of biodiesel and petrodiesel were incorporated into diesel engine oils. The oxidative stability, detergency and antiwear performance of the formulated diesel oils were evaluated. The results indicated that, compared with petrodiesel, biodiesel was more liable to promote oxidation degradation of diesel oils, leading to worse oxidative stability, detergency and antiwear ability of the oils.展开更多
The network structures of smart substations and the characteristics of industrial Ethernet switches are analyzed.The testing technologies of network systems based on smart substations are specifically elaborated.A vie...The network structures of smart substations and the characteristics of industrial Ethernet switches are analyzed.The testing technologies of network systems based on smart substations are specifically elaborated.A viewpoint is proposed that special testing policy&method of smart substation networks should be followed,so that the results can reveal the real network data exchange performance of the whole station.This view ensures the safety and stability of smart substations and lays a foundation for future upgrades and expansions.展开更多
Objective To evaluate the efficacy and safety of Ding Xin Recipe(DXR)combined with amiodarone in patients with PVCs.Methods A total of360patients with PVCs across7centers in China were randomly assigned in a1:1:1ratio...Objective To evaluate the efficacy and safety of Ding Xin Recipe(DXR)combined with amiodarone in patients with PVCs.Methods A total of360patients with PVCs across7centers in China were randomly assigned in a1:1:1ratio to receive up to8weeks of amiodarone combined with DXR placebo(amiodarone group),DXR combined with amiodarone placebo(DXR group),or DXR combined with amiodarone(DCA group)from July2012to December2013.Randomization was conducted according to a centralized randomization schedule prepared by an independent steering committee.Staff and patients at all sites were masked to treatment allocation.All patients received best-evidence advice.The primary outcome was the efficacy for treating PVCs,with efficacy assessed by the reduction of premature ventricular contractions.Other outcome measures included PVCs-related symptom scores.All data were analyzed by intention to treat.Results The efficacy for treating PVCs in the DCA group(90.7%)significantly increased compared with that in the amiodarone group(72.3%)and the DXR group(73.9%).The frequency,the degree,and the duration per week of heart palpitations,chest tightness,shortness of breath and fatigue improved significantly in the DCA group in comparison with the amiodarone group and the DXR group(P<0.05),while no significant difference was observed in the improvement of insomnia among the three groups(P>0.05).With regard to laboratory parameters for safety,there were no clinically relevant changes in the three groups.Conclusion The present study demonstrates that DXR combined with amiodarone is significantly more effective than DXR or amiodarone alone for treating PVCs.展开更多
The safety and stability study on Northeast, North, East, Northwest and Central China power grids had been carried out, which provided technical supports to planning design of regional power grids. By analyzing safety...The safety and stability study on Northeast, North, East, Northwest and Central China power grids had been carried out, which provided technical supports to planning design of regional power grids. By analyzing safety and stability under severe faults in regional power grids, revealed weaknesses on power grid configurations and measures for preventing from loss of stability were presented. In comparison of various schemes of power system safety and stability among parts of power grids, more than two recommended schemes can be chosen as reference in planning design for regional power grids. Considering the safety and stability control measures necessary for each power grids, it is believed the trunk networks of all power grids can fulfill the third criteria of Guideline for Power System Safety and Stability, while the weakness and predominated hydropower may deteriorate safety and stability of power grids. The power grid shall be regulated in line with the variation of boundary conditions.展开更多
Appropriate base oils and homologous additives such as extreme pressure and anti-wear agents,oiliness agents and antioxidants were selected,and experiments testing the compatibility performance between additive,base o...Appropriate base oils and homologous additives such as extreme pressure and anti-wear agents,oiliness agents and antioxidants were selected,and experiments testing the compatibility performance between additive,base oil and other components were carried out to develop the SK and SD series of rolling oils for cold rolling of stainless steel.The developed oils were used in the stainless steel cold rolling lubrication experiments,and were successfully applied in the actual cold rolling operation of stainless steel.Compared with a foreign product,the tribological properties,the thermal oxidation stability,and the rolling lubrication performance of the developed stainless steel cold rolling oils were studied.Test results showed that the tribological properties of the thereby developed rolling oils and the reference one were almost at the same level,and to some extent the performance of rolling was even better than the foreign product,at the same time the stainless steel sheet could retain its well annealed performance.Meanwhile,within a certain range,the lubrication of the rolling oil became better as its viscosity increased at the same level of saponification value,which could provide a lower friction coefficient,so that a higher maximum reduction ratio of the rolled piece through a constant roll gap and a minimum thickness could be secured.Also,similar phenomena appeared as the saponification value increased at a same viscosity level of the rolling oils.展开更多
Monitoring the stability of steep slopes of open-pit mines is a major issue relating to production safety in mines.In order to determine the technical parameters of a new type of supervising system applied in monitori...Monitoring the stability of steep slopes of open-pit mines is a major issue relating to production safety in mines.In order to determine the technical parameters of a new type of supervising system applied in monitoring steep slopes of open-pit mines,the MSARMA method was used to establish analytical models for the monitoring system,given various parameter settings based on the description of mechanical monitoring principles.We used this sensitivity analysis to conclude that the setting of the most sensitive location of a mechanical monitoring system should be within a range of 1/5~1/2 of the lower part in a vertical direction of steep slopes,with a rational and feasible range of the dip angle setting between 0°~20°.Given the analytical results of our on-site experiments,we have shown that the parameters determined reflect the stability of steep slopes accurately and effectively.These conclusions provide a basis for the application of a new type of steep slope stability monitoring technology in open-pit mines.展开更多
Fluorosilicone oil is polysiloxane with alkyl side chains containing fluorine, and because of its excellent thermal oxidation stability, cold flow property and cryogenic property, it can be widely used as a high tempe...Fluorosilicone oil is polysiloxane with alkyl side chains containing fluorine, and because of its excellent thermal oxidation stability, cold flow property and cryogenic property, it can be widely used as a high temperature lubricant in the field of military aerospace industry. Two kinds of fluorosilicone oils, FSiO-a and FSiO-b, were synthesized by different pro- cessing means. FTICR MS was used to collect the information on composition and structure of the two polymers, respec- tively. The test results show that the two fluorosilicone oils have different contents of fluorine-containing chain segments (m/ n value), the maximum distribution of m/n value of FSiO-a oil ranges from 0.22 to 0.25, and that of FSiO-b oil ranges from 0.4 to 0.67. Difference in synthesis techniques makes this discrepancy and affects the quality and thermal stability of the fluoro- silicone oils.展开更多
The aim of the article is to propose the method of designing double regulation control valves used in heating installations, allowing to obtain a constant value of the so-called inner authority and thus the constancy ...The aim of the article is to propose the method of designing double regulation control valves used in heating installations, allowing to obtain a constant value of the so-called inner authority and thus the constancy of the valve control characteristic, regardless of the pre-setting value set on the valve. The shape of the valve's regulation characteristics is one of the main factors determining the quality of the quantitative regulation, and thus the stability of the system's operation and overall operating costs. For this reason, the issue discussed in the article is important and can be applied in practical implementations of the valve sizing and the valve selection. The analysis was based on the relations binding the hydraulic resistances occurring inside the control valve, and the corresponding flow factors, using original author's proposal. The experimental verification was performed on a special measuring stand prepared for this purpose, measuring the values of the medium volume flow at a constant differential pressure, and then the results were converted into values of the flow factor, used in the proposed mathematical model. The results confirm the thesis put forward and the proposed mathematical model. High convergence of the results of experimental verification with the proposed mathematical model was obtained.展开更多
基金the financial support from the Natural Science Foundation of Chongqing(Project NO. CSTC, 2011JJA90020)the Science Foundation for Young Teachers of Logistical Engineering University
文摘Different contents of biodiesel and petrodiesel were incorporated into diesel engine oils. The oxidative stability, detergency and antiwear performance of the formulated diesel oils were evaluated. The results indicated that, compared with petrodiesel, biodiesel was more liable to promote oxidation degradation of diesel oils, leading to worse oxidative stability, detergency and antiwear ability of the oils.
文摘The network structures of smart substations and the characteristics of industrial Ethernet switches are analyzed.The testing technologies of network systems based on smart substations are specifically elaborated.A viewpoint is proposed that special testing policy&method of smart substation networks should be followed,so that the results can reveal the real network data exchange performance of the whole station.This view ensures the safety and stability of smart substations and lays a foundation for future upgrades and expansions.
基金funding support from the National Natural Sciences Foundation of China (No. 81373574 and No. 81774213)the Guangdong 211 key Disciplines
文摘Objective To evaluate the efficacy and safety of Ding Xin Recipe(DXR)combined with amiodarone in patients with PVCs.Methods A total of360patients with PVCs across7centers in China were randomly assigned in a1:1:1ratio to receive up to8weeks of amiodarone combined with DXR placebo(amiodarone group),DXR combined with amiodarone placebo(DXR group),or DXR combined with amiodarone(DCA group)from July2012to December2013.Randomization was conducted according to a centralized randomization schedule prepared by an independent steering committee.Staff and patients at all sites were masked to treatment allocation.All patients received best-evidence advice.The primary outcome was the efficacy for treating PVCs,with efficacy assessed by the reduction of premature ventricular contractions.Other outcome measures included PVCs-related symptom scores.All data were analyzed by intention to treat.Results The efficacy for treating PVCs in the DCA group(90.7%)significantly increased compared with that in the amiodarone group(72.3%)and the DXR group(73.9%).The frequency,the degree,and the duration per week of heart palpitations,chest tightness,shortness of breath and fatigue improved significantly in the DCA group in comparison with the amiodarone group and the DXR group(P<0.05),while no significant difference was observed in the improvement of insomnia among the three groups(P>0.05).With regard to laboratory parameters for safety,there were no clinically relevant changes in the three groups.Conclusion The present study demonstrates that DXR combined with amiodarone is significantly more effective than DXR or amiodarone alone for treating PVCs.
文摘The safety and stability study on Northeast, North, East, Northwest and Central China power grids had been carried out, which provided technical supports to planning design of regional power grids. By analyzing safety and stability under severe faults in regional power grids, revealed weaknesses on power grid configurations and measures for preventing from loss of stability were presented. In comparison of various schemes of power system safety and stability among parts of power grids, more than two recommended schemes can be chosen as reference in planning design for regional power grids. Considering the safety and stability control measures necessary for each power grids, it is believed the trunk networks of all power grids can fulfill the third criteria of Guideline for Power System Safety and Stability, while the weakness and predominated hydropower may deteriorate safety and stability of power grids. The power grid shall be regulated in line with the variation of boundary conditions.
文摘Appropriate base oils and homologous additives such as extreme pressure and anti-wear agents,oiliness agents and antioxidants were selected,and experiments testing the compatibility performance between additive,base oil and other components were carried out to develop the SK and SD series of rolling oils for cold rolling of stainless steel.The developed oils were used in the stainless steel cold rolling lubrication experiments,and were successfully applied in the actual cold rolling operation of stainless steel.Compared with a foreign product,the tribological properties,the thermal oxidation stability,and the rolling lubrication performance of the developed stainless steel cold rolling oils were studied.Test results showed that the tribological properties of the thereby developed rolling oils and the reference one were almost at the same level,and to some extent the performance of rolling was even better than the foreign product,at the same time the stainless steel sheet could retain its well annealed performance.Meanwhile,within a certain range,the lubrication of the rolling oil became better as its viscosity increased at the same level of saponification value,which could provide a lower friction coefficient,so that a higher maximum reduction ratio of the rolled piece through a constant roll gap and a minimum thickness could be secured.Also,similar phenomena appeared as the saponification value increased at a same viscosity level of the rolling oils.
基金Project 1053G032 supported by the Youth Science Foundation of Educational Committee of Heilongjiang Province
文摘Monitoring the stability of steep slopes of open-pit mines is a major issue relating to production safety in mines.In order to determine the technical parameters of a new type of supervising system applied in monitoring steep slopes of open-pit mines,the MSARMA method was used to establish analytical models for the monitoring system,given various parameter settings based on the description of mechanical monitoring principles.We used this sensitivity analysis to conclude that the setting of the most sensitive location of a mechanical monitoring system should be within a range of 1/5~1/2 of the lower part in a vertical direction of steep slopes,with a rational and feasible range of the dip angle setting between 0°~20°.Given the analytical results of our on-site experiments,we have shown that the parameters determined reflect the stability of steep slopes accurately and effectively.These conclusions provide a basis for the application of a new type of steep slope stability monitoring technology in open-pit mines.
文摘Fluorosilicone oil is polysiloxane with alkyl side chains containing fluorine, and because of its excellent thermal oxidation stability, cold flow property and cryogenic property, it can be widely used as a high temperature lubricant in the field of military aerospace industry. Two kinds of fluorosilicone oils, FSiO-a and FSiO-b, were synthesized by different pro- cessing means. FTICR MS was used to collect the information on composition and structure of the two polymers, respec- tively. The test results show that the two fluorosilicone oils have different contents of fluorine-containing chain segments (m/ n value), the maximum distribution of m/n value of FSiO-a oil ranges from 0.22 to 0.25, and that of FSiO-b oil ranges from 0.4 to 0.67. Difference in synthesis techniques makes this discrepancy and affects the quality and thermal stability of the fluoro- silicone oils.
文摘The aim of the article is to propose the method of designing double regulation control valves used in heating installations, allowing to obtain a constant value of the so-called inner authority and thus the constancy of the valve control characteristic, regardless of the pre-setting value set on the valve. The shape of the valve's regulation characteristics is one of the main factors determining the quality of the quantitative regulation, and thus the stability of the system's operation and overall operating costs. For this reason, the issue discussed in the article is important and can be applied in practical implementations of the valve sizing and the valve selection. The analysis was based on the relations binding the hydraulic resistances occurring inside the control valve, and the corresponding flow factors, using original author's proposal. The experimental verification was performed on a special measuring stand prepared for this purpose, measuring the values of the medium volume flow at a constant differential pressure, and then the results were converted into values of the flow factor, used in the proposed mathematical model. The results confirm the thesis put forward and the proposed mathematical model. High convergence of the results of experimental verification with the proposed mathematical model was obtained.