Field evaluation of a ground-coupled heat pump in hot-summer and cold-winter regions 被引量:1
1
作者 雷飞 《Journal of Chongqing University》 CAS 2011年第4期159-167,共9页
The experimental performance of small-sized ground-coupled heat pump (GCHP) is researched intensively. However, there are little data documenting the operation performance of existing large-sized GCHP system. We prese... The experimental performance of small-sized ground-coupled heat pump (GCHP) is researched intensively. However, there are little data documenting the operation performance of existing large-sized GCHP system. We presented the actual performance measurement of a GCHP installed for apartment buildings in Wuhan, Hubei province, P. R. China. The system was constructed with a closed vertical typed ground heat exchanger with a total pipe length of 32 000 m. During one year, various operating parameters were monitored, including the outdoor temperature, the flow rate, the electrical consumption, and the water temperature. The seasonal coefficients of performances of the heat pumps and the system based on the measured data were found to be 4.01 and 2.96 in the cooling season, and 3.54 and 2.86 in the heating season, respectively. The GCHP system was more economical than the air-source room air conditioner in the energy efficiency which was increased by 29% in cooling mode and 50% in heating mode. There was an obvious heat imbalance of soil between the injection rate and the extraction rate in the residential GCHP system operation. 展开更多
关键词 联合地面的热泵 性能的系数 地面热 exchanger 回答评估
下载PDF
Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter 被引量:2
2
作者 庄兆意 张承虎 +1 位作者 王海燕 孙德兴 《Transactions of Tianjin University》 EI CAS 2010年第6期461-466,共6页
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running... Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range. 展开更多
关键词 污水来源 热泵单位 性能(警察) 的系数 部分负担 平行操作
下载PDF