第三方患者体验测评对提升心外科护理质量的效果评价 被引量:1
1
作者 赵巧燕 王春丽 夏宁 《临床心身疾病杂志》 CAS 2021年第1期154-157,共4页
目的探讨第三方患者体验测评对提升心外科护理质量的效果。方法委托第三方机构对我院8743例心外科住院患者进行问卷测评,根据调查时间分为改进前组与改进后组,比较改进前后心外科住院患者的总满意率、认同度及忠诚度占比及医疗质量服务... 目的探讨第三方患者体验测评对提升心外科护理质量的效果。方法委托第三方机构对我院8743例心外科住院患者进行问卷测评,根据调查时间分为改进前组与改进后组,比较改进前后心外科住院患者的总满意率、认同度及忠诚度占比及医疗质量服务评分。结果改进后组患者总满意率、认同度及忠诚度占比均较改进前组显著提升(P<0.01)。改进后组患者医疗服务质量各项评分显著高于改进前组(P<0.01)。结论第三方患者体验测评可提升心外科护理质量的效果,具有临床推广价值。 展开更多
关键词 心外科 患者体验测评 第三方 护理质量 满意率
下载PDF
Evaluation of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification
2
作者 Ahmed Shawky Shawata Tarek El Nimr +1 位作者 Reda Ahmed Morsy Khaled M. Elshahat 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第7期343-349,共7页
Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent do... Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent dosimeters (TLD) is performed in many radiotherapy departments to verify the dose delivered during treatment. A total of 40 TLD divided into two batches (one of 20 and other of 20 TLD) were used. Different doses of Co6~ beam were delivered to the TLD chips at different depths. Diodes were irradiated at different depths in a (30 x 30 x 30) cm3 water slab phantom with various conditions of Field sizes, monitor units and SSDs. Results: The limitation of the in-vivo dosimetry technique is that dose can only be in system readout difficulty and type of readout (TLD system and diode) as the patient dose is directly measured. Several authors have investigated the measurements was 1.3%, with a standard deviation of 2.6%. Results were normally distributed around a mean as -0.39 and 0.34 respectively. After the evaluation of in vivo dosimetry brain case as an example, the mean doses for both eyes were 1.8%, with a standard deviation of 2.7%. These results are similar to studies conducted with diodes and TLD's. Conclusion: The diode is superior to TLD, since the diode measurements can be obtained on line and allows an immediate check. Other advantages of diodes include high sensitivity, good spatial resolution, and small size, simplicity of used. 展开更多
关键词 In vivo dosimetry uncertainty in experimental measurements calibration TLD dosimetry semi-conductor (di-ode) dosimetry
下载PDF