An output-only modal identification method by a combination use of the peak-picking method and the cross spectrum methods are presented. Meanwhile, a novel mode shape optimum method of the deck is proposed. The method...An output-only modal identification method by a combination use of the peak-picking method and the cross spectrum methods are presented. Meanwhile, a novel mode shape optimum method of the deck is proposed. The methods are applied to the operational modal identification system of the Runyang Suspension Bridge, which can be used to obtain the modal parameters of the bridge from out-only data sets collected by its structural health monitoring system (SHMS). As an example, the vibration response data of the deck, cable and tower recorded during typhoon Matsa excitation are used to illustrate the program application. Some of the modal frequencies observed from deck vibration responses are also found in the vibration responses of the cable and the tower. The results show that some modal shapes of the deck are strongly coupled with the cable and the tower. By comparing the identification results from the operational modal system with those from field measurements, a good agreement between them is achieved, but some modal frequencies identified from the operational modal identification system (OMIS), such as L1 and L2, obviously decrease compared with those from the field measurements.展开更多
The extending of a cantilever and transverse moving of a drilling floor enable the jack-up to operate in several well positions after the Jack-up has pitched. The cantilever allowable load nephogram is the critical re...The extending of a cantilever and transverse moving of a drilling floor enable the jack-up to operate in several well positions after the Jack-up has pitched. The cantilever allowable load nephogram is the critical reference which can evaluate the jack-up's drilling ability, design the cantilever structure and instruct a jack-up manager to make the operations safe. The intent of this paper is to explore the interrelationships between the cantilever position, drilling floor and the loads including wind force, the stand set-back weight etc., through analyzing the structure and load characteristics of the x-type cantilever and the simplified mechanics model with the restriction of the maximum moment capacity of the cantilever single side beam. Referring to several typical position designs load values, the cantilever allowable load nephogram is obtained by using the suitable interpolation method. The paper gives a method for cantilever allowable load design, which is proved reliable and effective by the calculation example.展开更多
基金The National High Technology Research and Development Program of China(863Program)(No.2006AA04Z416)
文摘An output-only modal identification method by a combination use of the peak-picking method and the cross spectrum methods are presented. Meanwhile, a novel mode shape optimum method of the deck is proposed. The methods are applied to the operational modal identification system of the Runyang Suspension Bridge, which can be used to obtain the modal parameters of the bridge from out-only data sets collected by its structural health monitoring system (SHMS). As an example, the vibration response data of the deck, cable and tower recorded during typhoon Matsa excitation are used to illustrate the program application. Some of the modal frequencies observed from deck vibration responses are also found in the vibration responses of the cable and the tower. The results show that some modal shapes of the deck are strongly coupled with the cable and the tower. By comparing the identification results from the operational modal system with those from field measurements, a good agreement between them is achieved, but some modal frequencies identified from the operational modal identification system (OMIS), such as L1 and L2, obviously decrease compared with those from the field measurements.
文摘The extending of a cantilever and transverse moving of a drilling floor enable the jack-up to operate in several well positions after the Jack-up has pitched. The cantilever allowable load nephogram is the critical reference which can evaluate the jack-up's drilling ability, design the cantilever structure and instruct a jack-up manager to make the operations safe. The intent of this paper is to explore the interrelationships between the cantilever position, drilling floor and the loads including wind force, the stand set-back weight etc., through analyzing the structure and load characteristics of the x-type cantilever and the simplified mechanics model with the restriction of the maximum moment capacity of the cantilever single side beam. Referring to several typical position designs load values, the cantilever allowable load nephogram is obtained by using the suitable interpolation method. The paper gives a method for cantilever allowable load design, which is proved reliable and effective by the calculation example.