根据交直流互联电网出现的直流落点谐波从高电压级向低电压级的传导过程和低电压级非线性负荷谐波向高电压级的扩散过程的不同,提出了一种基于等效注入电流的城市电网谐波传导特性分析方法,将两种情况下的谐波电流在谐波国标框架下统一...根据交直流互联电网出现的直流落点谐波从高电压级向低电压级的传导过程和低电压级非线性负荷谐波向高电压级的扩散过程的不同,提出了一种基于等效注入电流的城市电网谐波传导特性分析方法,将两种情况下的谐波电流在谐波国标框架下统一,得出一致行为评价。注意到城市电网电缆大量使用带来的高次谐波放大,提出潮流谐波比作为输送单位基波潮流的谐波含量评价指标,用以评价由电网参数变化以及电缆使用带来的谐波变化。应用所提方法计算了在某直流落点从500 k V变电站到10 k V母线谐波传导过程,并与实测数据相比较,揭示了谐波从高电压级向低电压级的传导规律和分析了城市电网电缆使用引起的谐波放大,验证了方法的有效性。展开更多
RLC model is used to estimate the coupling noise between interconnect wires and make some analysis through the simulation result. Based on the analysis conclusion,some algorithms are developed to adjust the rou ting ...RLC model is used to estimate the coupling noise between interconnect wires and make some analysis through the simulation result. Based on the analysis conclusion,some algorithms are developed to adjust the rou ting result with crosstalk constraint.展开更多
The adsorption capacity of activated carbon modified with KMnO4 (potassium permanganate) for Cr(VI) from aqueous solution was investigated. The modified activated carbon was characterized by SEM (scanning electro...The adsorption capacity of activated carbon modified with KMnO4 (potassium permanganate) for Cr(VI) from aqueous solution was investigated. The modified activated carbon was characterized by SEM (scanning electron microscopy), FT-IR (Fourier transform infrared spectrometer), and N2 adsorption/desorption tests. Adsorption of Cr(VI) from aqueous solution onto the activated carbon was investigated in a batch system. In the present study, the effect of various parameters such as pH, contact time and initial concentration on the adsorption capacity were determined by ICP-AES (inductively coupled plasma atomic emission spectrometry). The Cr(VI) adsorption on the activated carbon conforms to the Langmuir and Freundlich isothermal adsorption equation. The rates of adsorption were found to conform to pseudo-second order kinetic. The modified activated carbon can be an effective adsorbent for Cr(VI) from the aqueous solution.展开更多
文摘根据交直流互联电网出现的直流落点谐波从高电压级向低电压级的传导过程和低电压级非线性负荷谐波向高电压级的扩散过程的不同,提出了一种基于等效注入电流的城市电网谐波传导特性分析方法,将两种情况下的谐波电流在谐波国标框架下统一,得出一致行为评价。注意到城市电网电缆大量使用带来的高次谐波放大,提出潮流谐波比作为输送单位基波潮流的谐波含量评价指标,用以评价由电网参数变化以及电缆使用带来的谐波变化。应用所提方法计算了在某直流落点从500 k V变电站到10 k V母线谐波传导过程,并与实测数据相比较,揭示了谐波从高电压级向低电压级的传导规律和分析了城市电网电缆使用引起的谐波放大,验证了方法的有效性。
文摘RLC model is used to estimate the coupling noise between interconnect wires and make some analysis through the simulation result. Based on the analysis conclusion,some algorithms are developed to adjust the rou ting result with crosstalk constraint.
文摘The adsorption capacity of activated carbon modified with KMnO4 (potassium permanganate) for Cr(VI) from aqueous solution was investigated. The modified activated carbon was characterized by SEM (scanning electron microscopy), FT-IR (Fourier transform infrared spectrometer), and N2 adsorption/desorption tests. Adsorption of Cr(VI) from aqueous solution onto the activated carbon was investigated in a batch system. In the present study, the effect of various parameters such as pH, contact time and initial concentration on the adsorption capacity were determined by ICP-AES (inductively coupled plasma atomic emission spectrometry). The Cr(VI) adsorption on the activated carbon conforms to the Langmuir and Freundlich isothermal adsorption equation. The rates of adsorption were found to conform to pseudo-second order kinetic. The modified activated carbon can be an effective adsorbent for Cr(VI) from the aqueous solution.