The transmission equation of microdisk resonator is obtained by the transfer matrix method.The physical model is built and the electric field distribution,output spectrum and phase of the microdisk resonator are simul...The transmission equation of microdisk resonator is obtained by the transfer matrix method.The physical model is built and the electric field distribution,output spectrum and phase of the microdisk resonator are simulated by three-dimensional finite element software.The influence of the structural parameters on transmission characteristics and the temperature sensing property of the microdisk resonator are studied deeply.The results show that the output spectrum will change significantly with the distance between the microdisk and the straight waveguide within a certain range but there is no apparent change in the phase of the output port.The extinction ratio and maxima sensitivity of the device will reach 30 dB and 45 pm/℃,respectively.Microdisk has higher integration,higher quality factor and wider free spectral range compared with common microring resonator.展开更多
Objective To observe the clinical efficacy of Wentong needling method in the treatment of long-term cough cases after common cold. Methods Wentong needling method was used in the treatment of 30 cases with long-term c...Objective To observe the clinical efficacy of Wentong needling method in the treatment of long-term cough cases after common cold. Methods Wentong needling method was used in the treatment of 30 cases with long-term cough after common cold. Acupoints including Quchi (曲池 LI 11, left side), Hegu (合谷, LI 4, left side), Lieque (列缺, LU 7, right side), Fenglong (丰隆', ST 40, right side), Chize (尺泽, LU 5, right side), Zusanli (足三里, ST 36, right side), Zhaohai (照海, KI 6, left side), Taichong (太冲h, LR 3, both sides), and Waiqiu (外丘, GB 36, left side) were selected. The treatment was given every other day. After one treatment course, the relation between the long-term cough cases after common cold and Wentong needling method clinical efficacy was observed from aspects of different ages, disease duration and disease degree. Results There were 18 cured cases (60.0%), 8 markedly effective cases (26.7%), 4 effective cases (13.33%), and 0 invalid case (0.0%). The total effective rate was 200%. The treatment efficacy of cough patients after common cold of less than 24 months was better than that of more than 24 months. Along with the increasing of age, the cured and markedly effective rate was of certain downward tendency. Along with the increasing of treatment times, the cured and markedly effective rate increased. Conclusion The clinical efficacy of Wentong needling method is obvious in the treatment of long-term cough cases after common cold.展开更多
In this paper, we present a stable single-photon detection method based on Si-avalanche photodiode(Si-APD) operating in Geiger mode with a large temperature variation range. By accurate temperature sensing and direct ...In this paper, we present a stable single-photon detection method based on Si-avalanche photodiode(Si-APD) operating in Geiger mode with a large temperature variation range. By accurate temperature sensing and direct current(DC) bias voltage compensation, the single-photon detector can work stably in Geiger mode from-40 °C to 35 °C with an almost constant avalanche gain. It provides a solution for single-photon detection at outdoor operation in all-weather conditions.展开更多
基金National Natural Science Foundation of China(No.61762057)Natural Science Foundation of Gansu Province(No.18JR3RA123)。
文摘The transmission equation of microdisk resonator is obtained by the transfer matrix method.The physical model is built and the electric field distribution,output spectrum and phase of the microdisk resonator are simulated by three-dimensional finite element software.The influence of the structural parameters on transmission characteristics and the temperature sensing property of the microdisk resonator are studied deeply.The results show that the output spectrum will change significantly with the distance between the microdisk and the straight waveguide within a certain range but there is no apparent change in the phase of the output port.The extinction ratio and maxima sensitivity of the device will reach 30 dB and 45 pm/℃,respectively.Microdisk has higher integration,higher quality factor and wider free spectral range compared with common microring resonator.
文摘Objective To observe the clinical efficacy of Wentong needling method in the treatment of long-term cough cases after common cold. Methods Wentong needling method was used in the treatment of 30 cases with long-term cough after common cold. Acupoints including Quchi (曲池 LI 11, left side), Hegu (合谷, LI 4, left side), Lieque (列缺, LU 7, right side), Fenglong (丰隆', ST 40, right side), Chize (尺泽, LU 5, right side), Zusanli (足三里, ST 36, right side), Zhaohai (照海, KI 6, left side), Taichong (太冲h, LR 3, both sides), and Waiqiu (外丘, GB 36, left side) were selected. The treatment was given every other day. After one treatment course, the relation between the long-term cough cases after common cold and Wentong needling method clinical efficacy was observed from aspects of different ages, disease duration and disease degree. Results There were 18 cured cases (60.0%), 8 markedly effective cases (26.7%), 4 effective cases (13.33%), and 0 invalid case (0.0%). The total effective rate was 200%. The treatment efficacy of cough patients after common cold of less than 24 months was better than that of more than 24 months. Along with the increasing of age, the cured and markedly effective rate was of certain downward tendency. Along with the increasing of treatment times, the cured and markedly effective rate increased. Conclusion The clinical efficacy of Wentong needling method is obvious in the treatment of long-term cough cases after common cold.
基金supported by the National Natural Science Foundation of China(No.11374105)
文摘In this paper, we present a stable single-photon detection method based on Si-avalanche photodiode(Si-APD) operating in Geiger mode with a large temperature variation range. By accurate temperature sensing and direct current(DC) bias voltage compensation, the single-photon detector can work stably in Geiger mode from-40 °C to 35 °C with an almost constant avalanche gain. It provides a solution for single-photon detection at outdoor operation in all-weather conditions.