Objective To determine whether the convergences of tactile information also occur at thalamic ventroposterolateral nucleus in rats, we investigated the properties of tactile responses of the thalamic ventroposterolate...Objective To determine whether the convergences of tactile information also occur at thalamic ventroposterolateral nucleus in rats, we investigated the properties of tactile responses of the thalamic ventroposterolateral nucleus in rats. Methods Unit responses were recorded extracellularly from thalamic ventroposterolateral nucleus in anesthetized rats. Results Among 156 neurons examined, 140 neurons (89.7%) had the single, continual and small receptive fields, and 16 neurons (10.3%) had two discrete receptive fields. Some neurons exhibited different responses to the same intensity stimulation which delivered to different points in their receptive fields. In addition, 4.5% neurons (n -- 7) responded only to locomotive stimulation but not to a punctiform tactile stimulation. Conclusion The majority of neurons in ventroposterolateral nucleus of rats have the spatial, temporal and submodal characteristics of cutaneous receptors, while the minority of neurons exhibit the responses of interaction of different peripheral receptors. Therefore, it is con- cluded that there are convergences of tactile information at the ventroposterolateral nucleus of rats.展开更多
Set points of the indoor air temperature and relative humidity in short-term staying location were studied. In this condition, the thermal reaction of human body varied with the ramp changes of the environmental therm...Set points of the indoor air temperature and relative humidity in short-term staying location were studied. In this condition, the thermal reaction of human body varied with the ramp changes of the environmental thermal parameters.The change rules of about 60 subjects′ thermal reaction to the ramp change of environment were surveyed, and the effect of air movement on the thermal reaction during transient condition was considered by using a questionnaire. With the experimental results and research findings under stable condition, a way to set environmental parameters of short-time staying location was recommended.展开更多
To measure the pulsed neutron of a pulsed fission source, an organic scintillation fiber (OSF) detector with separation structure has been designed. The proposed detector employs UV optical fibers as the light guide...To measure the pulsed neutron of a pulsed fission source, an organic scintillation fiber (OSF) detector with separation structure has been designed. The proposed detector employs UV optical fibers as the light guide, and the sensitive region of the detector is composed of a linear array of OSFs, which are individually connected to the optical fibers. The other end of the light guide is coupled to a photomultiplier tube. The key properties of the device including the energy response, time response, neutron sensitivity, and radiation effect of the optical fiber were studied. The detector has a relatively high n/γ sensitivity ratio, which increases as the diameter of the OSF decreases, and ratios greater than 10 could be achieved when the diameter of the OSF is less than 0.3 nun. The sensitivity of the detector to neutrons ranges from 10-14 to 10-20 C cm2/n, and has a response time of 3 ns (FWHM). The proposed detector is also highly flexible. For instance, the probe can be set close to the source, while the PMT can be placed far away from radiation, allowing easy shielding. Due to these characteristics, pulsed fission neutrons in the vicinity of the source can be accurately measured.展开更多
文摘Objective To determine whether the convergences of tactile information also occur at thalamic ventroposterolateral nucleus in rats, we investigated the properties of tactile responses of the thalamic ventroposterolateral nucleus in rats. Methods Unit responses were recorded extracellularly from thalamic ventroposterolateral nucleus in anesthetized rats. Results Among 156 neurons examined, 140 neurons (89.7%) had the single, continual and small receptive fields, and 16 neurons (10.3%) had two discrete receptive fields. Some neurons exhibited different responses to the same intensity stimulation which delivered to different points in their receptive fields. In addition, 4.5% neurons (n -- 7) responded only to locomotive stimulation but not to a punctiform tactile stimulation. Conclusion The majority of neurons in ventroposterolateral nucleus of rats have the spatial, temporal and submodal characteristics of cutaneous receptors, while the minority of neurons exhibit the responses of interaction of different peripheral receptors. Therefore, it is con- cluded that there are convergences of tactile information at the ventroposterolateral nucleus of rats.
文摘Set points of the indoor air temperature and relative humidity in short-term staying location were studied. In this condition, the thermal reaction of human body varied with the ramp changes of the environmental thermal parameters.The change rules of about 60 subjects′ thermal reaction to the ramp change of environment were surveyed, and the effect of air movement on the thermal reaction during transient condition was considered by using a questionnaire. With the experimental results and research findings under stable condition, a way to set environmental parameters of short-time staying location was recommended.
文摘To measure the pulsed neutron of a pulsed fission source, an organic scintillation fiber (OSF) detector with separation structure has been designed. The proposed detector employs UV optical fibers as the light guide, and the sensitive region of the detector is composed of a linear array of OSFs, which are individually connected to the optical fibers. The other end of the light guide is coupled to a photomultiplier tube. The key properties of the device including the energy response, time response, neutron sensitivity, and radiation effect of the optical fiber were studied. The detector has a relatively high n/γ sensitivity ratio, which increases as the diameter of the OSF decreases, and ratios greater than 10 could be achieved when the diameter of the OSF is less than 0.3 nun. The sensitivity of the detector to neutrons ranges from 10-14 to 10-20 C cm2/n, and has a response time of 3 ns (FWHM). The proposed detector is also highly flexible. For instance, the probe can be set close to the source, while the PMT can be placed far away from radiation, allowing easy shielding. Due to these characteristics, pulsed fission neutrons in the vicinity of the source can be accurately measured.