期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
医源性胆道损伤的原因及处理 被引量:4
1
作者 马渊平 苏河 《甘肃科技》 1999年第6期36-36,共1页
关键词 医源性 胆道损伤 临床处理 胆囊切除 手术创作
下载PDF
Magnetic Helical Micro-and Nanorobots:Toward Their Biomedical Applications 被引量:9
2
作者 Famin Qiu Bradley J.Nelson 《Engineering》 SCIE EI 2015年第1期21-26,共6页
Magnetic helical micro- and nanorobots can perform 3D navigation in various liquids with a sub- micrometer precision under low-strength rotating magnetic fields (〈 10 rer). Since magnetic fields with low strengths ... Magnetic helical micro- and nanorobots can perform 3D navigation in various liquids with a sub- micrometer precision under low-strength rotating magnetic fields (〈 10 rer). Since magnetic fields with low strengths are harmless to cells and tissues, magnetic helical micro/ nanorobots are promising tools for biomedical applications, such as minimally invasive surgery, cell manipulation and analysis, and targeted therapy. This review provides general information on magnetic helical micro/nanorobots, including their fabrication, motion control, and further functionalization for biomedical applications. 展开更多
关键词 magnetic helical micro/nanorobots mobilemicro/nanorobots artificial bacterial flagella (ABFs) FUNCTIONALIZATION biomedical applications
下载PDF
Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses
3
作者 Paolo Berretta Marco Di Eusanio 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第6期504-510,共7页
Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved des... Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved despite increasing age of patients and increasing bur- den of comorbidities. However, despite such excellent results and its well-established position, conventional AVR has undergone great de- velopment over the previous two decades. Such progress, by way of less irtvasive incisions and use of new technologies, including tran- scatheter aortic valve implantation and sutureless valve prostheses, is intended to reduce the traumatic impact of the surgical procedure, thus fulfilling lower risk patients' expectations on the one hand, and extending the operability toward increasingly high-risk patients on the other. Sutureless and rapid deployment aortic valves are biological, pericardial prostheses that anchor within the aortic annulus with no more than three sutures. The sutureless prostheses, by avoiding the passage and the tying of the sutures, significantly reduce operative times and may improve outcomes. However, there is still a paucity of robust, evidence-based data on the role and performance of sutureless AVR. Therefore, strongest long-term data, randomized studies and registry data are required to adequately assess the durability and long-term outcomes of sutureless aortic valve replacement. 展开更多
关键词 Aortic valve replacement Minimally invasive Rapid deployment prosthesis Sutureless valve
下载PDF
Establishment and implementation of safety check project for invasive procedures outside the operating room
4
作者 Yan Hou Xiaoyu Di +2 位作者 Chanell Concepcion Xiaoyan Shen Ying Sun 《International Journal of Nursing Sciences》 CSCD 2021年第2期199-203,I0005,共6页
Objective:This study aimed to describe the implementation of the surgical safety check policy and the surgical safety checklist for invasive procedures outside the operating room(OR)and evaluate its effectiveness.Meth... Objective:This study aimed to describe the implementation of the surgical safety check policy and the surgical safety checklist for invasive procedures outside the operating room(OR)and evaluate its effectiveness.Methods:In 2017,to improve the safety of patients who underwent invasive procedures outside of the OR,the hospital quality and safety committee established the surgery safety check committee responsible for developing a new working plan,revise the surgery safety check policy,surgery safety check Keywords:Invasive procedures outside the operating room Safety management Surgical safety checklist Patient safety form,and provide training to the related staff,evaluated their competency,and implemented the updated surgical safety check policy and checklist.The study compared the data of pre-implementation(Apr to Sep 2017)and two post-implementation phases(Apr to Sep 2018,Apr to Sep 2019).It also evaluated the number of completed surgery safety checklist,correct signature,and correct timing of signature.Results:The results showed an increase in the completion rate of the safety checklist after the program implementation from 41.7%(521/1,249)to 90.4%(3,572/3,950),the correct rates of signature from 41.9%(218/521)to 99.0%(4,423/4,465),and the correct timing rates of signature from 34.4%(179/521)to 98.5%(4,401/4,465),with statistical significance(P<0.01).Conclusion:Implementing the updated surgery safety check significantly is a necessary and effective measure to ensure patient safety for those who underwent invasive procedures outside the OR.Implementing surgical safety checks roused up the clinical staff's compliance in performing safety checks,and enhanced team collaboration and communication. 展开更多
关键词 Invasive procedures outside the operating ROOM Safety management Surgical safety checklist Patient safety
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部