The localized micro-galvanic corrosion process and the kinetic information of Mg-(7,9)Al-1Fe-x Nd alloys were investigated by in situ observation under electrochemical control and in situ atomic force microscopy(AFM)i...The localized micro-galvanic corrosion process and the kinetic information of Mg-(7,9)Al-1Fe-x Nd alloys were investigated by in situ observation under electrochemical control and in situ atomic force microscopy(AFM)in an electrolyte environment.The results revealed that the formation of the Nd-rich phase in alloys resulted in a decrease in the Volta potential difference from~400 m V(AlFe3/α-Mg)to~220 mV(Nd-rich/α-Mg),reducing the corrosion products around the cathodic phase and corrosion current density of the microscale area.The addition of Nd significantly improved the corrosion resistance,mainly due to the suppression of the micro-galvanic corrosion between the second phases and substrate.Finally,the corrosion mechanism of Mg-(7,9)Al-1Fe-x Nd alloys was discussed based on in situ observations and electrochemical results.展开更多
The degradation coefficient is proposed to evaluate the degradation degree of organic coatings by directly anaIyzing the Bode plots of the electrochemical impedance spectroscopy (EIS) data. This paper investigated t...The degradation coefficient is proposed to evaluate the degradation degree of organic coatings by directly anaIyzing the Bode plots of the electrochemical impedance spectroscopy (EIS) data. This paper investigated the degradation of phenolic epoxy coating/tinplate system by EIS and the degradation coefficient value, which correlates well with the results of breakpoint frequency and variation of phase angle at 10 Hz. Furthermore, the degradation process was confirmed by scanning electron microscope (SEM) and scanning probe microscopy (SPM). It is concluded that degradation coefficient can be used for the fast evaluation of degradation degree of organic coatings in practical appli- cations.展开更多
AIM: To identify multi-detector computed tomography (MDCT) features most predictive of serous cystadenomas (SCAs), correlating with histopathology, and to study the impact of cyst size and MDCT technique on reade...AIM: To identify multi-detector computed tomography (MDCT) features most predictive of serous cystadenomas (SCAs), correlating with histopathology, and to study the impact of cyst size and MDCT technique on reader performance. METHODS: The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs. Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or 〉≥3 cm) and scanning protocols (dedicated vs routine). RESULTS: 28/164 cysts (mean size, 39 mm; range, 8-92 mm) were diagnosed as SCA on pathology. The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28, 78.6%), surface Iobulations (25/28, 89.3%) and central scar (9/28, 32.4%). Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P = 0.0001). The sensitivity, specificity and PPV of central scar and of combined microcystic appearance and Iobulations were 32.4%/100%/100% and 68%/100%/100%, respectively. The reader confidence was higher for lesions 〉 3 cm (P = 0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P 〉 0.05). CONCLUSION: Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs. Microcystic morphology is the most significant CT feature in diagnosis of SCA. A combination of microcystic appearance and surface Iobulations offers accuracy comparable to central scar with higher sensitivity.展开更多
The corrosion behavior of tinplate cans containing coffee was investigated using novel electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) sensors.The contents of iron and tin dissolved in cans w...The corrosion behavior of tinplate cans containing coffee was investigated using novel electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) sensors.The contents of iron and tin dissolved in cans were detected by inductively coupled plasma mass spectrometer(ICP-MS),and the morphology of corroded surface was observed by optical microscopy and scanning probe microscopy(SPM).The results reveal that the coating resistance,charge transfer resistance and noise resistance decrease with the prolongation of storage time.The iron and tin contents in cans increase with the storage time,while the bump height of coating surface increases from 30 nm to 80 nm during the corrosion of twelve months.The existence of deformation would enhance the corrosion process of tinplate cans.Finally,the corrosion mechanism of tinplate cans in coffee was proposed.展开更多
The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/...The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/L NaC1 + 0.01 mol/L Na2S203 solution under slow-strain-rate-testing (SSRT) conditions. Moreover, the characteristics of L-crack's surface morphology and potential distribution with scanning Kelvin probe (SKP) before and after SSRT were also discussed. Compared with S-crack, L-crack is propagated and the features of crack propagation can be obtained. After propagation, the noise amplitudes increase with increasing stress and accelerating corrosion, the white noises at low and high frequencies (WE and WH) of the later stage are one order of magnitude larger than that at early stage in the current power spectral densities (PSDs). The potential PSDs also increase, but WH disappears. In addition, the crack propagation can be demonstrated according to variation of probability distribution, surface morphology and potential distribution.展开更多
A combination of NAA and micro-PIXE was used to study concentrations and distributions of platinum group elements (PGE) in ores from Xinjie Cu-Pt deposit.The NAA results of the bulk indicate that the ores belong to th...A combination of NAA and micro-PIXE was used to study concentrations and distributions of platinum group elements (PGE) in ores from Xinjie Cu-Pt deposit.The NAA results of the bulk indicate that the ores belong to the enriched Pt-Pd type.The element concentration maps of scanning micro-PIXE for the ores show that the occurence form of Pt is independent arsenide minerals. No PGE were detected in chalcopyrite of Xinjie Cu-Pt deposit. These information are economically beneficial to the mineral smelting process.展开更多
AIM:To retrospectively evaluate the imaging features of pancreatic intraductal papillary mucinous neoplasms (IPMNs) in multi-detector row computed tomography (MDCT).METHODS: A total of 20 patients with pathologically-...AIM:To retrospectively evaluate the imaging features of pancreatic intraductal papillary mucinous neoplasms (IPMNs) in multi-detector row computed tomography (MDCT).METHODS: A total of 20 patients with pathologically-confirmed intraductal papillary mucinous neoplasms (IPMNs) were included in this study. Axial MDCT images combined with CT angiography (CTA) and multiplanar volume reformations (MPVR) or curved reformations (CR) were preoperatively acquired. Two radiologists (Tan L and Wang DB) reviewed all the images in consensus using an interactive picture archiving and communication system. The disputes in readings were resolved through consultation with a third experienced radiologist (Chen KM). Finally, the findings and diagnoses were compared with the pathologic results.RESULTS: The pathological study revealed 12 malignant IPMNs and eight benign IPMNs. The diameters of the cystic lesions and main pancreatic ducts (MPDs) were significantly larger in malignant IPMNs compared with those of the benign IPMNs (P<0.05). The combined-type IPMNs had a higher rate of malignancy than the other two types of IPMNs (P<0.05). Tumors with mural nodules and thick septa had a significantly higher incidence of malignancy than tumors without these features (P<0.05). Communication of side-branch IPMNs with the MPD was present in nine cases at pathologic examination. Seven of them were identified from CTA and MPVR or CR images. From comparison with the pathological diagnosis, the sensitivity, specificity, and accuracy of MDCT in characterizing the malignancy of IPMN of the pancreas were determined to be 100%, 87.5% and 95%, respectively.CONCLUSION: MDCT with CTA and MPVR or CR techniques can elucidate the imaging features of IPMNs and help predict the malignancy of these tumors.展开更多
A new scan matching method for mobile robot localization is presented, which takes line segment as the feature and matches the real scans in the given reference map by relationships of the directional-defined line seg...A new scan matching method for mobile robot localization is presented, which takes line segment as the feature and matches the real scans in the given reference map by relationships of the directional-defined line segments. The alignment was done by hierarchically identifying the multiple relationships and the result was recorded in a correspondence matrix, where the best match is defined and selected for localization. It is indicated that the searching algorithm of the best match can find the ambiguities and get rid of them. This method with less computational cost works well in occluded environment, and can correct the error in pose estimation without the need for the estimation itself. The efficiency, accuracy and robustness of this method were verified by experiments of localization in an occluded environment and a long-distance indoor navigation.展开更多
A scanning probe microscope(SPM)stage controlled by three stepper motors is designed,which has more flexibilitiesthan that of one motor controlled stage,while the control whom is more complicated.In this project,we bu...A scanning probe microscope(SPM)stage controlled by three stepper motors is designed,which has more flexibilitiesthan that of one motor controlled stage,while the control whom is more complicated.In this project,we build the stageactions in an Arduino microcontroller,and finite state machine(FSM)is also built in the Arduino micro controller to communicatewith a computer and a radio frequency(RF)controller.A special displaying scheme with five states is employed to indicatethe operation of the stage.Finally,the stage is fully tested and has a700nm resolution in Z motion of the SPM.展开更多
基金financial support from the National Natural Science Foundation of China(No.51961026)。
文摘The localized micro-galvanic corrosion process and the kinetic information of Mg-(7,9)Al-1Fe-x Nd alloys were investigated by in situ observation under electrochemical control and in situ atomic force microscopy(AFM)in an electrolyte environment.The results revealed that the formation of the Nd-rich phase in alloys resulted in a decrease in the Volta potential difference from~400 m V(AlFe3/α-Mg)to~220 mV(Nd-rich/α-Mg),reducing the corrosion products around the cathodic phase and corrosion current density of the microscale area.The addition of Nd significantly improved the corrosion resistance,mainly due to the suppression of the micro-galvanic corrosion between the second phases and substrate.Finally,the corrosion mechanism of Mg-(7,9)Al-1Fe-x Nd alloys was discussed based on in situ observations and electrochemical results.
基金Supported by Major State Basic Research Program of China ("973"Program,No. 2011CB610500)
文摘The degradation coefficient is proposed to evaluate the degradation degree of organic coatings by directly anaIyzing the Bode plots of the electrochemical impedance spectroscopy (EIS) data. This paper investigated the degradation of phenolic epoxy coating/tinplate system by EIS and the degradation coefficient value, which correlates well with the results of breakpoint frequency and variation of phase angle at 10 Hz. Furthermore, the degradation process was confirmed by scanning electron microscope (SEM) and scanning probe microscopy (SPM). It is concluded that degradation coefficient can be used for the fast evaluation of degradation degree of organic coatings in practical appli- cations.
文摘AIM: To identify multi-detector computed tomography (MDCT) features most predictive of serous cystadenomas (SCAs), correlating with histopathology, and to study the impact of cyst size and MDCT technique on reader performance. METHODS: The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs. Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or 〉≥3 cm) and scanning protocols (dedicated vs routine). RESULTS: 28/164 cysts (mean size, 39 mm; range, 8-92 mm) were diagnosed as SCA on pathology. The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28, 78.6%), surface Iobulations (25/28, 89.3%) and central scar (9/28, 32.4%). Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P = 0.0001). The sensitivity, specificity and PPV of central scar and of combined microcystic appearance and Iobulations were 32.4%/100%/100% and 68%/100%/100%, respectively. The reader confidence was higher for lesions 〉 3 cm (P = 0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P 〉 0.05). CONCLUSION: Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs. Microcystic morphology is the most significant CT feature in diagnosis of SCA. A combination of microcystic appearance and surface Iobulations offers accuracy comparable to central scar with higher sensitivity.
基金Project(2011CB610500)supported by the National Key Basic Research Program of ChinaProject(13JCZDJC29500)supported by the Natural Science Foundation of Tianjin Municipality,ChinaProject(20130032110029)supported by the Specialized Research Fund for the Doctoral Program of Higher Education,China
文摘The corrosion behavior of tinplate cans containing coffee was investigated using novel electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) sensors.The contents of iron and tin dissolved in cans were detected by inductively coupled plasma mass spectrometer(ICP-MS),and the morphology of corroded surface was observed by optical microscopy and scanning probe microscopy(SPM).The results reveal that the coating resistance,charge transfer resistance and noise resistance decrease with the prolongation of storage time.The iron and tin contents in cans increase with the storage time,while the bump height of coating surface increases from 30 nm to 80 nm during the corrosion of twelve months.The existence of deformation would enhance the corrosion process of tinplate cans.Finally,the corrosion mechanism of tinplate cans in coffee was proposed.
基金Project(2006CB605004) supported by the National Basic Research Program of China
文摘The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/L NaC1 + 0.01 mol/L Na2S203 solution under slow-strain-rate-testing (SSRT) conditions. Moreover, the characteristics of L-crack's surface morphology and potential distribution with scanning Kelvin probe (SKP) before and after SSRT were also discussed. Compared with S-crack, L-crack is propagated and the features of crack propagation can be obtained. After propagation, the noise amplitudes increase with increasing stress and accelerating corrosion, the white noises at low and high frequencies (WE and WH) of the later stage are one order of magnitude larger than that at early stage in the current power spectral densities (PSDs). The potential PSDs also increase, but WH disappears. In addition, the crack propagation can be demonstrated according to variation of probability distribution, surface morphology and potential distribution.
文摘A combination of NAA and micro-PIXE was used to study concentrations and distributions of platinum group elements (PGE) in ores from Xinjie Cu-Pt deposit.The NAA results of the bulk indicate that the ores belong to the enriched Pt-Pd type.The element concentration maps of scanning micro-PIXE for the ores show that the occurence form of Pt is independent arsenide minerals. No PGE were detected in chalcopyrite of Xinjie Cu-Pt deposit. These information are economically beneficial to the mineral smelting process.
基金Supported by Shanghai Leading Academic Discipline Project,No.S30203
文摘AIM:To retrospectively evaluate the imaging features of pancreatic intraductal papillary mucinous neoplasms (IPMNs) in multi-detector row computed tomography (MDCT).METHODS: A total of 20 patients with pathologically-confirmed intraductal papillary mucinous neoplasms (IPMNs) were included in this study. Axial MDCT images combined with CT angiography (CTA) and multiplanar volume reformations (MPVR) or curved reformations (CR) were preoperatively acquired. Two radiologists (Tan L and Wang DB) reviewed all the images in consensus using an interactive picture archiving and communication system. The disputes in readings were resolved through consultation with a third experienced radiologist (Chen KM). Finally, the findings and diagnoses were compared with the pathologic results.RESULTS: The pathological study revealed 12 malignant IPMNs and eight benign IPMNs. The diameters of the cystic lesions and main pancreatic ducts (MPDs) were significantly larger in malignant IPMNs compared with those of the benign IPMNs (P<0.05). The combined-type IPMNs had a higher rate of malignancy than the other two types of IPMNs (P<0.05). Tumors with mural nodules and thick septa had a significantly higher incidence of malignancy than tumors without these features (P<0.05). Communication of side-branch IPMNs with the MPD was present in nine cases at pathologic examination. Seven of them were identified from CTA and MPVR or CR images. From comparison with the pathological diagnosis, the sensitivity, specificity, and accuracy of MDCT in characterizing the malignancy of IPMN of the pancreas were determined to be 100%, 87.5% and 95%, respectively.CONCLUSION: MDCT with CTA and MPVR or CR techniques can elucidate the imaging features of IPMNs and help predict the malignancy of these tumors.
基金Sponsored by the National High Technology Research and Development Program of China(Grant No.2006AA040203)The National Natural Science Foundation of China(Grant No.60475032 and 60775062)the Program for New Century Excellent Talents in University(Grant No.NCET-07-0538)
文摘A new scan matching method for mobile robot localization is presented, which takes line segment as the feature and matches the real scans in the given reference map by relationships of the directional-defined line segments. The alignment was done by hierarchically identifying the multiple relationships and the result was recorded in a correspondence matrix, where the best match is defined and selected for localization. It is indicated that the searching algorithm of the best match can find the ambiguities and get rid of them. This method with less computational cost works well in occluded environment, and can correct the error in pose estimation without the need for the estimation itself. The efficiency, accuracy and robustness of this method were verified by experiments of localization in an occluded environment and a long-distance indoor navigation.
文摘A scanning probe microscope(SPM)stage controlled by three stepper motors is designed,which has more flexibilitiesthan that of one motor controlled stage,while the control whom is more complicated.In this project,we build the stageactions in an Arduino microcontroller,and finite state machine(FSM)is also built in the Arduino micro controller to communicatewith a computer and a radio frequency(RF)controller.A special displaying scheme with five states is employed to indicatethe operation of the stage.Finally,the stage is fully tested and has a700nm resolution in Z motion of the SPM.