This paper describes the scanning assembly principle and construction of scanning assembly sample.The factors that affect assembly accuracy are analyzed.There are two steps in CCD focal plane scanning assembly.The fir...This paper describes the scanning assembly principle and construction of scanning assembly sample.The factors that affect assembly accuracy are analyzed.There are two steps in CCD focal plane scanning assembly.The first is rough assembly,and the second is accurate assembly.In this paper,the moiré fringe is introduced in judging assembly accuracy directly and accurately.The equation for optical transmission characteristics of CCD Moiré fringes is presented.The measurement of Moiré fringes can be completed when some conditions are satisfied.2D_assembly error can be obtained by using digital correlation filtering technique.Finally,the result of focal plane scanning assembly is presented.The result is in good accordance with theory.展开更多
This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of trans...This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.展开更多
文摘This paper describes the scanning assembly principle and construction of scanning assembly sample.The factors that affect assembly accuracy are analyzed.There are two steps in CCD focal plane scanning assembly.The first is rough assembly,and the second is accurate assembly.In this paper,the moiré fringe is introduced in judging assembly accuracy directly and accurately.The equation for optical transmission characteristics of CCD Moiré fringes is presented.The measurement of Moiré fringes can be completed when some conditions are satisfied.2D_assembly error can be obtained by using digital correlation filtering technique.Finally,the result of focal plane scanning assembly is presented.The result is in good accordance with theory.
文摘This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.