期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
广西制造全承载式车身高地板客车的必要性和现实性
1
作者 林又树 《广西交通科技》 1994年第3期17-20,共4页
为了克服非承载式车身客车需要保留强度足够大的车架等的缺点,提出采用全承载式车身高地板客车,这种客车整车自重大为降低,受载合理,节省材料,方便行李装卸和提高舒适性等。
关键词 大客车 承载·式 车身 结构
全文增补中
Seismic Behavior of Specially Shaped Column Joints with X-Shaped Reinforcement 被引量:3
2
作者 戎贤 张健新 李艳艳 《Transactions of Tianjin University》 EI CAS 2013年第2期110-117,共8页
To investigate the seismic behavior of specially shaped column joints with X-shaped reinforcement,two groups of specimens with or without X-shaped reinforcement in joint core region were tested under constant axial co... To investigate the seismic behavior of specially shaped column joints with X-shaped reinforcement,two groups of specimens with or without X-shaped reinforcement in joint core region were tested under constant axial compression load and low reversed cyclic loading,which imitated low to moderate earthquake force.The seismic behavior of specially shaped column joints with X-shaped reinforcement in terms of bearing capacity,displacement,ductility,hysteretic curve,stiffness degradation and energy dissipation was studied and compared to that without Xshaped reinforcement in joint core region.With the damage estimation model,the accumulated damage was analyzed.The shearing capacity formula of specially shaped column joints reinforced by X-shaped reinforcement was proposed with a simple form.The test results show that X-shaped reinforcement is an effective measure for improving the seismic behavior of specially shaped column joints including deformation behavior,ductility and hysteretic characteristic.All specimens were damaged with gradual stiffness degeneration.In addition,X-shaped reinforcement in the joint core region is an effective way to lighten the degree of cumulated damage.The good seismic performance obtained from the specially shaped column joint with X-shaped reinforcement can be used in engineering applications.The test value is higher than the calculated value,which indicates that the formula is safe for the design of specially shaped column joints. 展开更多
关键词 specially shaped column JOINT low cyclic loading X-shaped reinforcement seismic behavior
下载PDF
Test on Muddy Soil Reinforcement by Negative Pressure and Electro-Osmosis Inside Cover-Bearing-Type Bucket Foundation for Offshore Wind Turbines 被引量:1
3
作者 张浦阳 丁红岩 +1 位作者 翟少华 熊康平 《Transactions of Tianjin University》 EI CAS 2013年第1期10-16,共7页
Cover-bearing-type bucket foundation for offshore wind turbines has been paid more and more attention due to its low cost and great bearing capacity. In order to ensure the cover-bearing mode, the muddy soil inside th... Cover-bearing-type bucket foundation for offshore wind turbines has been paid more and more attention due to its low cost and great bearing capacity. In order to ensure the cover-bearing mode, the muddy soil inside the bucket foundation should be reinforced by some soil consolidation methods, such as negative pressure and electro-osmosis. Firstly, tests were conducted to obtain the reasonable current density. Meanwhile, to improve the electro-osmotic speed and effectiveness, other factors such as intermittent power and layout of electrode, were also studied in the tests. Then, the soil reinforcing tests by negative pressure combined with electro-osmosis were performed for the muddy soil consolidation inside the bucket foundation. The results showed that soil reinforcement by negative pressure was quicker and more obvious during the early phase, and electro-osmotic method can affect more range of soil by rational arrangement of electrodes. Compared with negative pressure, the electro-osmotic method was a continuous and relatively slow process of reinforcement, which was complementary to the negative pressure method. The voltage value of electro-osmosis had little effect on the muddy soil reinforcement inside the bucket foundation, and 1.5 A was chosen as the most reasonable current value for scale model testing in the electro-osmotic method. 展开更多
关键词 cover-bearing-type bucket foundation electro-osmosis negative pressure consolidation muddy soil
下载PDF
Experimental research on ultimate bearing capacity of grouted-round-steel-tube N-joint 被引量:5
4
作者 郑文忠 柳旭东 +1 位作者 张格明 张博一 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第3期322-329,共8页
As an important structural member in self-supporting concrete floor during construction,encased steel truss-concrete composite beam has brilliant prospect in outer-jacketing structures for adding stories or mega frame... As an important structural member in self-supporting concrete floor during construction,encased steel truss-concrete composite beam has brilliant prospect in outer-jacketing structures for adding stories or mega frame structures.Compared with encased angle truss,encased round steel tube truss can facilitate layout of itself in column and facilitate layout and anchorage of prestressed reinforcement placed horizontally.N-joint is wildly used in encased steel truss.For cave-in failure easily occurs in hollow steel-tube joint,the idea that the chord is grouted to increase cave-in bearing capacity of hollow tube is proposed.Test results of 8 grouted-round-steel-tube N-joints from the beginning of loading to failure are reported.Mechanical property and failure mode of this kind of truss joint are analyzed,and the formulas of ultimate bearing capacity of the joint corresponding to different failure modes are established.All these can provide basic data for spreading encased steel truss-concrete composite beam. 展开更多
关键词 groined-round-steel-tube N-joint model test simulated analysis failure mode bearing capacity
下载PDF
Mechanical property of single-bolted composite laminates 被引量:1
5
作者 王富生 王佩艳 +2 位作者 姬尧尧 刘志强 岳珠峰 《Journal of Central South University》 SCIE EI CAS 2014年第2期466-471,共6页
In order to investigate the effects of different geometrical parameters and pretightening loads on failure mode and bearing strength,a large number of single-bolted T300/QY8911 composite laminates were tested under st... In order to investigate the effects of different geometrical parameters and pretightening loads on failure mode and bearing strength,a large number of single-bolted T300/QY8911 composite laminates were tested under static tension load.Box-plot was used to extract the singular testing values of bearing strength and effective statistical values were obtained.T-test method of independent samples was used to study how much pretightening loads influence bearing strength.The results show that the geometrical parameters,such as ratios of width to hole diameter(w/d) and edge distance to hole diameter(e/d),remarkably influence failure mode and bearing strength.Net-section failure will occur when w/d is smaller than 4,and shear-out failure will occur when e/d is smaller than 2.Bearing failure or bearing and shear-out combined failure will occur when w/d is greater than 4 and e/d is greater than 2.There is an optimal combination of geometrical parameters to achieve the highest bearing strength.For most of specimens,pretightening loads do not explicitly influence bearing strength. 展开更多
关键词 single-bolted composite laminate geometrical parameter pretightening load singular testing values T-test method of independent samples
下载PDF
Seismic Behavior of Confined RC ColumnComposite Beam Joints
6
作者 张谦 于庆荣 +1 位作者 管俊峰 吴智敏 《Transactions of Tianjin University》 EI CAS 2014年第3期174-181,共8页
In order to evaluate the seismic behavior of confined RC column-composite beam joints, five interior joints were tested under low cyclic reversed load. The weakening extent of flanges, the number of studs, and whether... In order to evaluate the seismic behavior of confined RC column-composite beam joints, five interior joints were tested under low cyclic reversed load. The weakening extent of flanges, the number of studs, and whether to reinforce weakened flanges were used as parameters in designing these five joints. Failure characteristics, hysteretic curves, skeleton curves, ductility, energy dissipation, strength degradation, and stiffness degradation were analyzed. The test results revealed that the steel beam flanges in the joints were equivalent to the tie rod. Weakened flanges resulted in poor seismic behavior; however, the seismic behavior could be improved by increasing studs and reinforcing weakened flanges. The joint steel plate hoops, equivalent to stirrups, did not yield when the maximum load was reached, but yielded when the failure load was reached for the joints with shear failure. Increasing stud-type joints and reinforcing flange-type joints ensured good seismic behavior and met project requirements. Based on the experimental results, the failure mechanism of the joints was discussed, and the shear capacity equations of the joints was presented. 展开更多
关键词 seismic behavior JOINT confined RC column composite beam
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部