An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concret...An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concrete strengths of the columns were 30 MPa and 60 MPa.The primary variables considered were the concrete strength and the amount of transversereinforcement. Test results indicate that smaller hoop spacing provides higher column capacity andgreater strength enhancement in a confined concrete core of columns. For the same lateralconfinement, high strength concrete columns develop lower strength enhancement than normal strengthconcrete columns. Both the strength enhancement ratio (f'_(cc) /f'_(co)) and the column capacityratio (P_(test)/P_o) were observed to show linear increase variations with rho_s f_(yt)/f'_c incircular columns.展开更多
To better study the behavior of confined concrete, this paper presents the basic hypothesis of uhimate equilibrium of confined concrete and the unified yield criteria of confining material. Based on the static equilib...To better study the behavior of confined concrete, this paper presents the basic hypothesis of uhimate equilibrium of confined concrete and the unified yield criteria of confining material. Based on the static equilibrium condition and yield criteria of components, a unified bearing capacity model of confined concrete column is proposed, and a simplified calculating equation of the model is also given. The model captures the character of confined concrete column. Effects of the confinement effect ratio, the lateral confinement ratio, unconfined concrete strength and the properties of confining material on the bearing capacity of confined concrete column are carefully considered. The model may be applicable to the calculation of bearing capacity of steel-confined concrete, concrete filled steel tube and FRP-confined concrete. The predictions of the model agree well with test data.展开更多
External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concre...External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concrete, the yield criterion of bidirectional FRP is presented based on the static equilibrium condition in this paper, and a model for calculating the bearing capacity of bidirectional FRP confined concrete is established. The model can capture the character of bidirectional FRP confined concrete. Effects of the confinement effect coefficient, the unconfined concrete strength and the material properties of FRP on bearing capacity are analyzed. Results show that each parameter has different effects on the bearing capacity of bidirectional FRP confined concrete.展开更多
Based on the assumption of additional three-hinge arching action,an analytical method was proposed to predict the additional load of lateral restraint reinforced concrete (RC) slab under compressive membrane action (C...Based on the assumption of additional three-hinge arching action,an analytical method was proposed to predict the additional load of lateral restraint reinforced concrete (RC) slab under compressive membrane action (CMA),and its ultimate load could be obtained by adding pure bending load. The experiment of twelve one-way RC slabs supported by shear-walls was carried out,and the calculations of this proposed method provide good predictions for the experimental evidences. The influence of some design parameters on bearing capacity was also investigated. It is shown that the effect of vertical load on ending shear-wall on the ultimate load capacity can be generally neglected when the bending restraint is satisfied. The additional load capacity also decreases with the increase of the span-to-height ratio of central slab. When reducing the reinforcement area,the additional load capacity is increased,and this method can be used to save steel or enhance the ultimate load capacity of low steel ratio slab.展开更多
文摘An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concrete strengths of the columns were 30 MPa and 60 MPa.The primary variables considered were the concrete strength and the amount of transversereinforcement. Test results indicate that smaller hoop spacing provides higher column capacity andgreater strength enhancement in a confined concrete core of columns. For the same lateralconfinement, high strength concrete columns develop lower strength enhancement than normal strengthconcrete columns. Both the strength enhancement ratio (f'_(cc) /f'_(co)) and the column capacityratio (P_(test)/P_o) were observed to show linear increase variations with rho_s f_(yt)/f'_c incircular columns.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50538060)the Excellent Young College Teacher Foundation of Anhui Prov-ince(Grant No.2009SQRZ081)
文摘To better study the behavior of confined concrete, this paper presents the basic hypothesis of uhimate equilibrium of confined concrete and the unified yield criteria of confining material. Based on the static equilibrium condition and yield criteria of components, a unified bearing capacity model of confined concrete column is proposed, and a simplified calculating equation of the model is also given. The model captures the character of confined concrete column. Effects of the confinement effect ratio, the lateral confinement ratio, unconfined concrete strength and the properties of confining material on the bearing capacity of confined concrete column are carefully considered. The model may be applicable to the calculation of bearing capacity of steel-confined concrete, concrete filled steel tube and FRP-confined concrete. The predictions of the model agree well with test data.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50538060)the Excellent Young College Teacher Foundation of Anhui Province(Grant No.2009SQRZ081)
文摘External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concrete, the yield criterion of bidirectional FRP is presented based on the static equilibrium condition in this paper, and a model for calculating the bearing capacity of bidirectional FRP confined concrete is established. The model can capture the character of bidirectional FRP confined concrete. Effects of the confinement effect coefficient, the unconfined concrete strength and the material properties of FRP on bearing capacity are analyzed. Results show that each parameter has different effects on the bearing capacity of bidirectional FRP confined concrete.
基金Project(PCSIRT0518) supported by the Program for Changjiang Scholars and Innovative Research Team in University of China
文摘Based on the assumption of additional three-hinge arching action,an analytical method was proposed to predict the additional load of lateral restraint reinforced concrete (RC) slab under compressive membrane action (CMA),and its ultimate load could be obtained by adding pure bending load. The experiment of twelve one-way RC slabs supported by shear-walls was carried out,and the calculations of this proposed method provide good predictions for the experimental evidences. The influence of some design parameters on bearing capacity was also investigated. It is shown that the effect of vertical load on ending shear-wall on the ultimate load capacity can be generally neglected when the bending restraint is satisfied. The additional load capacity also decreases with the increase of the span-to-height ratio of central slab. When reducing the reinforcement area,the additional load capacity is increased,and this method can be used to save steel or enhance the ultimate load capacity of low steel ratio slab.