An intuitive 2D model of circular electrical impedance tomography (EIT) sensor with small size electrodes is established based on the theory of analytic functions. The validation of the model is proved using the res...An intuitive 2D model of circular electrical impedance tomography (EIT) sensor with small size electrodes is established based on the theory of analytic functions. The validation of the model is proved using the result from the solution of Laplace equation. Suggestions on to electrode optimization and explanation to the ill-condition property of the sensitivity matrix are provided based on the model, which takes electrode distance into account and can be generalized to the sensor with any simple connected region through a conformal transformation. Image reconstruction algorithms based on the model are implemented to show feasibility of the model using experimental data collected from the EIT system developed in Tianjin University. In the simulation with a human chestlike configuration, electrical conductivity distributions are reconstructed using equi-potential backprojection (EBP) and Tikhonov regularization (TR) based on a conformal transformation of the model. The algorithms based on the model are suitable for online image reconstruction and the reconstructed results are aood both in size and position.展开更多
We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electri...We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model. Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%, for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.展开更多
This paper presents the use of a high performance dual-plane electrical resistance tomography (ERT) system and a local dual-sensor conductance probe to measure the vertical upward oil-in-water pipe flows in which the ...This paper presents the use of a high performance dual-plane electrical resistance tomography (ERT) system and a local dual-sensor conductance probe to measure the vertical upward oil-in-water pipe flows in which the mean oil volume fraction is up to 23.1%. A sensitivity coefficient back-projection (SBP) algorithm was adopted to reconstruct the flow distributions and a cross correlation method was applied to obtain the oil velocity distributions. The oil volume fraction and velocity distributions obtained from both measurement techniques were compared and good agreement was found, which indicates that the ERT tech- nique can be used to measure the low fraction oil-water flows. Finally, the factors affecting measurement precision were discussed.展开更多
This paper presents different views on electrode modelling, which include electrode electrochemistry models for modelling the effects of electrode-electrolyte interface, electric field electrode models for modelling e...This paper presents different views on electrode modelling, which include electrode electrochemistry models for modelling the effects of electrode-electrolyte interface, electric field electrode models for modelling electrode geometry, and electrode models for modelling the effects of electrode common mode voltage and double layer capacitance. Taking the full electrode models into consideration in electrical impedance tomography (EIT) will greatly help the optimised approach to a good solution and further understanding of the measurement principle.展开更多
The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrica...The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrical impedance tomography(EIT) measurements and reconstructed images by means of principal component analysis(PCA).In the experiments in vivo,43 cycles of heart-beat rhythm could be detected by PCA when the volunteer held breath;9 breathing cycles and 50 heart-beat cycles could be detected by PCA ...展开更多
A new electrical resistance tomography (ERT) system, based on the bi-directional current pulse technique, is de- veloped. Polarization effects at the electrodes are eliminated. During each half cycle of the excitation...A new electrical resistance tomography (ERT) system, based on the bi-directional current pulse technique, is de- veloped. Polarization effects at the electrodes are eliminated. During each half cycle of the excitation process, direct current (DC) is used as the excitation source and filtering is not needed. Moreover, using optimized data collection protocol, the number of current injections for a 16-electrode system is reduced to 14 for 104 independent readings of an image. Experimental results showed that the system is effective using the sensitivity coefficient algorithm for image reconstruction.展开更多
A conveyor belt driven by wound rotor motors produces dynamic tension, velocity and accelerationduring starting. The terrible situation (such as resonance) in dynamic analysis and design is that system naturalfrequenc...A conveyor belt driven by wound rotor motors produces dynamic tension, velocity and accelerationduring starting. The terrible situation (such as resonance) in dynamic analysis and design is that system naturalfrequencies are equal to those for switching off electric resistances. This paper analyzes and determines systemnatural frequencies based on a modeling method of receptances with the analysis of sub-systems model and of theprinciple of their addition and conveyor loop closure. It also puts forward to calculate the time interval for switching off electric resistances. The starting of one conveyor is simulated by lumped-mass-spring-model software tofurther illustrate the influence of time interval for switching off electric resistances on conveyor dynamic behavior. Two methods are also compared. The receptance model is proved to be an excellent alternative.展开更多
基金Supported by National Natural Science Foundation of China (No.60532020,60301008,60472077,50337020), the High Tech-nique Research and Development Program of China (No.2001AA413210).
文摘An intuitive 2D model of circular electrical impedance tomography (EIT) sensor with small size electrodes is established based on the theory of analytic functions. The validation of the model is proved using the result from the solution of Laplace equation. Suggestions on to electrode optimization and explanation to the ill-condition property of the sensitivity matrix are provided based on the model, which takes electrode distance into account and can be generalized to the sensor with any simple connected region through a conformal transformation. Image reconstruction algorithms based on the model are implemented to show feasibility of the model using experimental data collected from the EIT system developed in Tianjin University. In the simulation with a human chestlike configuration, electrical conductivity distributions are reconstructed using equi-potential backprojection (EBP) and Tikhonov regularization (TR) based on a conformal transformation of the model. The algorithms based on the model are suitable for online image reconstruction and the reconstructed results are aood both in size and position.
基金Project supported partly by the National Science Foundation (No.BES-0411898) and the National Institues of Health (No. R01EB00178) USA
文摘We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model. Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%, for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.
基金Project (No. 15933) supported by the Royal Society-Chinese Acad-emy of Sciences Joint Project
文摘This paper presents the use of a high performance dual-plane electrical resistance tomography (ERT) system and a local dual-sensor conductance probe to measure the vertical upward oil-in-water pipe flows in which the mean oil volume fraction is up to 23.1%. A sensitivity coefficient back-projection (SBP) algorithm was adopted to reconstruct the flow distributions and a cross correlation method was applied to obtain the oil velocity distributions. The oil volume fraction and velocity distributions obtained from both measurement techniques were compared and good agreement was found, which indicates that the ERT tech- nique can be used to measure the low fraction oil-water flows. Finally, the factors affecting measurement precision were discussed.
文摘This paper presents different views on electrode modelling, which include electrode electrochemistry models for modelling the effects of electrode-electrolyte interface, electric field electrode models for modelling electrode geometry, and electrode models for modelling the effects of electrode common mode voltage and double layer capacitance. Taking the full electrode models into consideration in electrical impedance tomography (EIT) will greatly help the optimised approach to a good solution and further understanding of the measurement principle.
基金Supported by National Natural Science Foundation of China (No.60532020,No.60820106002,No.60672076)Supporting Program of the Ministry of Science and Technology of China (No.2006BAI03A00)
文摘The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrical impedance tomography(EIT) measurements and reconstructed images by means of principal component analysis(PCA).In the experiments in vivo,43 cycles of heart-beat rhythm could be detected by PCA when the volunteer held breath;9 breathing cycles and 50 heart-beat cycles could be detected by PCA ...
基金Project (No. 2001BA701A46) supported by the Hi-Tech Researchand Development Program (863) of China
文摘A new electrical resistance tomography (ERT) system, based on the bi-directional current pulse technique, is de- veloped. Polarization effects at the electrodes are eliminated. During each half cycle of the excitation process, direct current (DC) is used as the excitation source and filtering is not needed. Moreover, using optimized data collection protocol, the number of current injections for a 16-electrode system is reduced to 14 for 104 independent readings of an image. Experimental results showed that the system is effective using the sensitivity coefficient algorithm for image reconstruction.
文摘A conveyor belt driven by wound rotor motors produces dynamic tension, velocity and accelerationduring starting. The terrible situation (such as resonance) in dynamic analysis and design is that system naturalfrequencies are equal to those for switching off electric resistances. This paper analyzes and determines systemnatural frequencies based on a modeling method of receptances with the analysis of sub-systems model and of theprinciple of their addition and conveyor loop closure. It also puts forward to calculate the time interval for switching off electric resistances. The starting of one conveyor is simulated by lumped-mass-spring-model software tofurther illustrate the influence of time interval for switching off electric resistances on conveyor dynamic behavior. Two methods are also compared. The receptance model is proved to be an excellent alternative.