The P-SV wave reflection coefficients in VTI and HTI media were obtained by approximation of the Jilek(2002a and b)equation in orthotropic anisotropic media.An approximate equation for P-SV wave elastic impedance ca...The P-SV wave reflection coefficients in VTI and HTI media were obtained by approximation of the Jilek(2002a and b)equation in orthotropic anisotropic media.An approximate equation for P-SV wave elastic impedance can be derived from the combination of the new coefficients with S-wave elastic impedance(Duffaut et al.,2000).On this basis, the fluid identification factor in weakly anisotropic media was constructed and used to identify the Castagna and Smith(1994)lithologic combination and achieved good results. Finally,we specifically analyzed the anisotropic parameter impacts P-SV wave elastic impedance and fluid factor trends.展开更多
The influence of Ga and In on the electrochemical properties of Mg anode materials were investigated by the polarization and galvanostatic curve tests. The microstructure and the corroded surface of the Mg-In-Ga alloy...The influence of Ga and In on the electrochemical properties of Mg anode materials were investigated by the polarization and galvanostatic curve tests. The microstructure and the corroded surface of the Mg-In-Ga alloys were observed by scanning electron microscopy (SEM). The corrosion product of the Mg-0.8%In (mass fraction) and Mg-0.8%Ga-0.3%In alloy were determined by X-ray diffraction. The results show that no second phase exists in the Mg-xIn (x=0-0.8%) allloys. Intergranular compounds containing Ga and In elements occur in the Mg-0.8%In-xGa (x=0-0.8%) alloys. The addition of In into Mg as well as the addition of 0.05%-0.5%Ga into Mg-In alloy promotes the corrosion resistance. The addition of Ga into Mg-In alloys also promotes the electrochemical activity. The Mg-0.8%In-0.8%Ga alloy has the most negative mean potential,-1.682 V, which is more negative than -1.406 V in AZ91D. The corrosion type of the Mg-In-Ga alloys is general corrosion and the corrosion product is Mg(OH)2.展开更多
The effects of Hg and Ga on the electrochemical corrosion behaviors of the Mg-2%Hg, Mg-2%Ga and Mg-2%Hg-2%Ga (mass fraction) alloys were investigated by measurements of polarization curves, galvanostatic tests and mea...The effects of Hg and Ga on the electrochemical corrosion behaviors of the Mg-2%Hg, Mg-2%Ga and Mg-2%Hg-2%Ga (mass fraction) alloys were investigated by measurements of polarization curves, galvanostatic tests and measurements of electrochemical impedance spectroscopy. Scanning electron microscopy, X-ray diffractometry and energy dispersive spectrometry were employed to characterize the microstructures and the corroded surface of the above alloys. The results demonstrate that the microstructure of the Mg-2%Ga alloy is solid solution and the Mg-2%Hg and Mg-2%Hg-2%Ga alloys have white second-phases at the grain boundaries. The Mg-2%Ga alloy has the worst electrochemical activity and the best corrosion resistance, showing a mean potential of -1.48 V and a corrosion current density of 0.15 mA/cm2. The Mg-2%Hg-2%Ga alloy has the best electrochemical activity and the worst corrosion resistance, showing a mean potential of -1.848 V and a corrosion current density of 2.136 mA/cm2. The activation mechanism of the Mg-Hg-Ga alloy is dissolution-deposition of the Hg and Ga atoms.展开更多
基金sponsored by the National 973 Program(Grant No.2007CB209603)
文摘The P-SV wave reflection coefficients in VTI and HTI media were obtained by approximation of the Jilek(2002a and b)equation in orthotropic anisotropic media.An approximate equation for P-SV wave elastic impedance can be derived from the combination of the new coefficients with S-wave elastic impedance(Duffaut et al.,2000).On this basis, the fluid identification factor in weakly anisotropic media was constructed and used to identify the Castagna and Smith(1994)lithologic combination and achieved good results. Finally,we specifically analyzed the anisotropic parameter impacts P-SV wave elastic impedance and fluid factor trends.
基金Project(20110162120051)supported by Specialized Research Fund for the Doctor Program of Higher Education,ChinaProject(51101171)supported by the National Natural Science Foundation of China
文摘The influence of Ga and In on the electrochemical properties of Mg anode materials were investigated by the polarization and galvanostatic curve tests. The microstructure and the corroded surface of the Mg-In-Ga alloys were observed by scanning electron microscopy (SEM). The corrosion product of the Mg-0.8%In (mass fraction) and Mg-0.8%Ga-0.3%In alloy were determined by X-ray diffraction. The results show that no second phase exists in the Mg-xIn (x=0-0.8%) allloys. Intergranular compounds containing Ga and In elements occur in the Mg-0.8%In-xGa (x=0-0.8%) alloys. The addition of In into Mg as well as the addition of 0.05%-0.5%Ga into Mg-In alloy promotes the corrosion resistance. The addition of Ga into Mg-In alloys also promotes the electrochemical activity. The Mg-0.8%In-0.8%Ga alloy has the most negative mean potential,-1.682 V, which is more negative than -1.406 V in AZ91D. The corrosion type of the Mg-In-Ga alloys is general corrosion and the corrosion product is Mg(OH)2.
基金Project (MKPT-02-18) supported by the National Defense Science and Technology Industry Committee of ChinaProject (51101171)supported by the National Natural Science Foundation of China
文摘The effects of Hg and Ga on the electrochemical corrosion behaviors of the Mg-2%Hg, Mg-2%Ga and Mg-2%Hg-2%Ga (mass fraction) alloys were investigated by measurements of polarization curves, galvanostatic tests and measurements of electrochemical impedance spectroscopy. Scanning electron microscopy, X-ray diffractometry and energy dispersive spectrometry were employed to characterize the microstructures and the corroded surface of the above alloys. The results demonstrate that the microstructure of the Mg-2%Ga alloy is solid solution and the Mg-2%Hg and Mg-2%Hg-2%Ga alloys have white second-phases at the grain boundaries. The Mg-2%Ga alloy has the worst electrochemical activity and the best corrosion resistance, showing a mean potential of -1.48 V and a corrosion current density of 0.15 mA/cm2. The Mg-2%Hg-2%Ga alloy has the best electrochemical activity and the worst corrosion resistance, showing a mean potential of -1.848 V and a corrosion current density of 2.136 mA/cm2. The activation mechanism of the Mg-Hg-Ga alloy is dissolution-deposition of the Hg and Ga atoms.