Stabilizing pile is a kind of earth shoring structure frequently used in slope engineering. When the piles have cantilever segments above the ground,laggings are usually installed to avoid collapse of soil between pil...Stabilizing pile is a kind of earth shoring structure frequently used in slope engineering. When the piles have cantilever segments above the ground,laggings are usually installed to avoid collapse of soil between piles. Evaluating the earth pressure acting on laggings is of great importance in design process.Since laggings are usually less stiff than piles,the lateral pressure on lagging is much closer to active earth pressure. In order to estimate the lateral earth pressure on lagging more accurately,first,a model test of cantilever stabilizing pile and lagging systems was carried out. Then,basing the experimental results a three-dimensional sliding wedge model was established. Last,the calculation process of the total active force on lagging is presented based on the kinematic approach of limit analysis. A comparison is made between the total active force on lagging calculated by the formula presented in this study and the force on a same-size rigid retaining wall obtained from Rankine's theory. It is found that the proposed method fits well with the experimental results.Parametric studies show that the total active force on lagging increases with the growth of the lagging height and the lagging clear span; while decreases asthe soil internal friction angle and soil cohesion increase.展开更多
The conventional poststack inversion uses standard recursion formulas to obtain impedance in a single trace.It cannot allow for lateral regularization.In this paper,ID edge-preserving smoothing(EPS)fi lter is extended...The conventional poststack inversion uses standard recursion formulas to obtain impedance in a single trace.It cannot allow for lateral regularization.In this paper,ID edge-preserving smoothing(EPS)fi lter is extended to 2D/3D for setting precondition of impedance model in impedance inversion.The EPS filter incorporates a priori knowledge into the seismic inversion.The a priori knowledge incorporated from EPS filter preconditioning relates to the blocky features of the impedance model,which makes the formation interfaces and geological edges precise and keeps the inversion procedure robust.Then,the proposed method is performed on two 2D models to show its feasibility and stability.Last,the proposed method is performed on a real 3D seismic work area from Southwest China to predict reef reservoirs in practice.展开更多
基金financially supported by the National Key Technology Research and Development Program of the Ministry of Science and Technology of China under Grant No. 2012BAJ22B06
文摘Stabilizing pile is a kind of earth shoring structure frequently used in slope engineering. When the piles have cantilever segments above the ground,laggings are usually installed to avoid collapse of soil between piles. Evaluating the earth pressure acting on laggings is of great importance in design process.Since laggings are usually less stiff than piles,the lateral pressure on lagging is much closer to active earth pressure. In order to estimate the lateral earth pressure on lagging more accurately,first,a model test of cantilever stabilizing pile and lagging systems was carried out. Then,basing the experimental results a three-dimensional sliding wedge model was established. Last,the calculation process of the total active force on lagging is presented based on the kinematic approach of limit analysis. A comparison is made between the total active force on lagging calculated by the formula presented in this study and the force on a same-size rigid retaining wall obtained from Rankine's theory. It is found that the proposed method fits well with the experimental results.Parametric studies show that the total active force on lagging increases with the growth of the lagging height and the lagging clear span; while decreases asthe soil internal friction angle and soil cohesion increase.
基金The National Key S&T Special Projects (No. 2017ZX05008004-008)the National Natural Science Foundation of China (No. 41874146)+2 种基金the National Natural Science Foundation of China (No. 41704134)the Innovation Team of Youth Scientific and Technological in Southwest Petroleum University (No. 2017CXTD08)the Initiative Projects for Ph.Din China West Normal University (No. 19E063)
文摘The conventional poststack inversion uses standard recursion formulas to obtain impedance in a single trace.It cannot allow for lateral regularization.In this paper,ID edge-preserving smoothing(EPS)fi lter is extended to 2D/3D for setting precondition of impedance model in impedance inversion.The EPS filter incorporates a priori knowledge into the seismic inversion.The a priori knowledge incorporated from EPS filter preconditioning relates to the blocky features of the impedance model,which makes the formation interfaces and geological edges precise and keeps the inversion procedure robust.Then,the proposed method is performed on two 2D models to show its feasibility and stability.Last,the proposed method is performed on a real 3D seismic work area from Southwest China to predict reef reservoirs in practice.