Objective: To investigate the feasibility of chemosensitivity testing of antitumor drugs by flow cytometry in clinical applications so as to provide experimental and theoretical basis for the establishment of a novel ...Objective: To investigate the feasibility of chemosensitivity testing of antitumor drugs by flow cytometry in clinical applications so as to provide experimental and theoretical basis for the establishment of a novel antitumor drugs sensitivity testing and the screening of particular antitumor drugs. Methods: Detect the apoptosis rate of 12 cases of Molt-4 cell line, 57 cases of fresh clinical gastrointestinal tumor cells by Sub-G1 and Annexin V assay of flow cytometry under the effects of antitumor drugs at different times and the outcomes were compared with the ones of the MTT (3-(4,5-dimethylthiazolyl-2) -2,5-diphenyltetrazolium bromide) assay. Results: The lethality of drugs on Molt-4 cell, clinical gastrointestinal tumor cells had a positive correlation with the acting time of antidrugs by employing Annexin V, Sub-G1 and MTT assay. Drug-incurring maximum lethality of Annexin V assay was higher than MTT colorimetric assay, that of Sub-G1 was lower than MTT assay, the virtual times of Annexin V and Sub-G1 assay were obviously earlier than that of MTT colorimetric assay. Conclusion: Annexin V and Sub-G1 assay of flow cytometry can be taken as potent protocols testing anti-tumor drug chemosensitivity. Annexin V assay is featured by more sensitive, concise, reliable compared with the classical chemosensitivity testing assay of MTT colorimetric assay and it possesses clinical applied value.展开更多
基金National Development Program (973) Foundation for Key Basic Research (2004CB518705) (2002CB513100)National Natural Science Foundation of China (30570908)Key Research Foundation of Clinical Subject of Health Ministry of China "Cell Cycle Diagnosis and Analysis in Clinical Tumor (3)"
文摘Objective: To investigate the feasibility of chemosensitivity testing of antitumor drugs by flow cytometry in clinical applications so as to provide experimental and theoretical basis for the establishment of a novel antitumor drugs sensitivity testing and the screening of particular antitumor drugs. Methods: Detect the apoptosis rate of 12 cases of Molt-4 cell line, 57 cases of fresh clinical gastrointestinal tumor cells by Sub-G1 and Annexin V assay of flow cytometry under the effects of antitumor drugs at different times and the outcomes were compared with the ones of the MTT (3-(4,5-dimethylthiazolyl-2) -2,5-diphenyltetrazolium bromide) assay. Results: The lethality of drugs on Molt-4 cell, clinical gastrointestinal tumor cells had a positive correlation with the acting time of antidrugs by employing Annexin V, Sub-G1 and MTT assay. Drug-incurring maximum lethality of Annexin V assay was higher than MTT colorimetric assay, that of Sub-G1 was lower than MTT assay, the virtual times of Annexin V and Sub-G1 assay were obviously earlier than that of MTT colorimetric assay. Conclusion: Annexin V and Sub-G1 assay of flow cytometry can be taken as potent protocols testing anti-tumor drug chemosensitivity. Annexin V assay is featured by more sensitive, concise, reliable compared with the classical chemosensitivity testing assay of MTT colorimetric assay and it possesses clinical applied value.