Choosing the equipment with good shock-resistant p erformance and taking shock protection measures while designing the onboard sett ings, the safety of onboard settings can be assured when warships, especially su bmar...Choosing the equipment with good shock-resistant p erformance and taking shock protection measures while designing the onboard sett ings, the safety of onboard settings can be assured when warships, especially su bmarine subjected to non-contact underwater explosion, that is, these means can be used to limit the rattlespace (i.e., the maximum displacement of the equipme nt relative to the base) and the peak acceleration experienced by the equipment. Using shock-resistant equipments is one of shock protection means. The shock- resistant performance of the shock-resistant equipments should be verified in t he design phase of the equipments. The FEA (finite element analysis) software, for example, MSC.NASTRAN ○R , can be used to verify the shock-resistant performance. MSC.PATRAN ○R and MSC.NASTRAN are used for modeling and analyzing the floating raft vibration isolating equipment. The model of the floating raft and the floating raft vibration isolating system are theoretically analyzed and calculated, and the analysis results are in agreement with the test results. The transient response analysis of the system model follows the modal analysis of the floating raft vibration isolating system. And it is used to verify the shock-resistant performance. The ana lysis and calculation method used in this paper can be used to analyze the shock -resistant performance of onboard shock-resistant equipments.展开更多
This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient im...This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances.展开更多
The effects of adding alloy element zinc on the static and dynamic mechanical properties of copper-zinc alloy were investigated. Tensile and low cycle fatigue behaviors of the C11000 copper and H63 copper-zinc alloy w...The effects of adding alloy element zinc on the static and dynamic mechanical properties of copper-zinc alloy were investigated. Tensile and low cycle fatigue behaviors of the C11000 copper and H63 copper-zinc alloy were obtained by using a miniature tester that combined the functions of in situ tensile and fatigue testing. A piezoelectric actuator was adopted as the actuator for the fatigue testing, and the feasibility of the fatigue actuator was verified by the transient harmonic response analysis based on static tensile preload and dynamic sinusoidal load. The experimental results show that the yield strength and tensile strength of the C11000 copper are improved after adding 37%(mass fraction) zinc, and H63 copper-zinc alloy presents more obvious cyclic hardening behavior and more consumed irreversible plastic work during each stress cycle compared with C11000 copper for the same strain controlled cycling. Additionally, based on the Manson-Coffin theory, the strain-life equations of the two materials were also obtained. C11000 copper and H63 copper-zinc alloy show transition life of 16832 and 1788 cycles, respectively.展开更多
文摘Choosing the equipment with good shock-resistant p erformance and taking shock protection measures while designing the onboard sett ings, the safety of onboard settings can be assured when warships, especially su bmarine subjected to non-contact underwater explosion, that is, these means can be used to limit the rattlespace (i.e., the maximum displacement of the equipme nt relative to the base) and the peak acceleration experienced by the equipment. Using shock-resistant equipments is one of shock protection means. The shock- resistant performance of the shock-resistant equipments should be verified in t he design phase of the equipments. The FEA (finite element analysis) software, for example, MSC.NASTRAN ○R , can be used to verify the shock-resistant performance. MSC.PATRAN ○R and MSC.NASTRAN are used for modeling and analyzing the floating raft vibration isolating equipment. The model of the floating raft and the floating raft vibration isolating system are theoretically analyzed and calculated, and the analysis results are in agreement with the test results. The transient response analysis of the system model follows the modal analysis of the floating raft vibration isolating system. And it is used to verify the shock-resistant performance. The ana lysis and calculation method used in this paper can be used to analyze the shock -resistant performance of onboard shock-resistant equipments.
文摘This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances.
基金Projects(51275198,51422503)supported by the National Natural Science Foundation of ChinaProject(2012YQ030075)supported by Special Funds for Development of National Major Scientific Instruments and Equipments,China+1 种基金Project(NECT-12-0238)supported by Program for New Century Excellent Talents in University,ChinaProject(20150520108JH)supported by Young Scientist Fund of Jilin Province of China
文摘The effects of adding alloy element zinc on the static and dynamic mechanical properties of copper-zinc alloy were investigated. Tensile and low cycle fatigue behaviors of the C11000 copper and H63 copper-zinc alloy were obtained by using a miniature tester that combined the functions of in situ tensile and fatigue testing. A piezoelectric actuator was adopted as the actuator for the fatigue testing, and the feasibility of the fatigue actuator was verified by the transient harmonic response analysis based on static tensile preload and dynamic sinusoidal load. The experimental results show that the yield strength and tensile strength of the C11000 copper are improved after adding 37%(mass fraction) zinc, and H63 copper-zinc alloy presents more obvious cyclic hardening behavior and more consumed irreversible plastic work during each stress cycle compared with C11000 copper for the same strain controlled cycling. Additionally, based on the Manson-Coffin theory, the strain-life equations of the two materials were also obtained. C11000 copper and H63 copper-zinc alloy show transition life of 16832 and 1788 cycles, respectively.