This paper summarizes the development of hydro-projects in China,blended with an international perspective.It expounds major technical progress toward ensuring the safe construction of high dams and river harnessing,a...This paper summarizes the development of hydro-projects in China,blended with an international perspective.It expounds major technical progress toward ensuring the safe construction of high dams and river harnessing,and covers the theorization of uneven non-equilibrium sediment transport,inter-basin water diversion,giant hydro-generator units,pumped storage power stations,underground caverns,ecological protection,and so on.展开更多
The operation parameters (vibration, shaft displacement and pressure fluctuation) of No. 1 Francis reversible unit of Baoquan pumped-storage power station were measured on site in the no-load mode at net heads of 51...The operation parameters (vibration, shaft displacement and pressure fluctuation) of No. 1 Francis reversible unit of Baoquan pumped-storage power station were measured on site in the no-load mode at net heads of 518.04, 522.01 and 530.38 m, re- spectively. The rotational speed fluctuations in the no-load mode at three net heads were beyond synchronization requirement with obvious S-shaped characteristic, and misaligned guide vanes (MGV) had to be put into use for synchronization. Further analysis demonstrated that the rotating frequency signal was generally dominant in vibration and shaft displacement mixing signal in the no-load mode, while the frequency domain was wide without an obvious main frequency in pressure fluctuation mixing signal. Besides, the SSTκ-ω turbulence model was adopted to simulate the four quadrant characteristic curves of Baoquan model pump-turbine at three gate openings, and the relative error between simulation results and model test data was within ±6%, indicating that the simulation method in this paper is feasible and S-shaped characteristic of the pump-turbine can be simulated with CFD method.展开更多
文摘This paper summarizes the development of hydro-projects in China,blended with an international perspective.It expounds major technical progress toward ensuring the safe construction of high dams and river harnessing,and covers the theorization of uneven non-equilibrium sediment transport,inter-basin water diversion,giant hydro-generator units,pumped storage power stations,underground caverns,ecological protection,and so on.
文摘The operation parameters (vibration, shaft displacement and pressure fluctuation) of No. 1 Francis reversible unit of Baoquan pumped-storage power station were measured on site in the no-load mode at net heads of 518.04, 522.01 and 530.38 m, re- spectively. The rotational speed fluctuations in the no-load mode at three net heads were beyond synchronization requirement with obvious S-shaped characteristic, and misaligned guide vanes (MGV) had to be put into use for synchronization. Further analysis demonstrated that the rotating frequency signal was generally dominant in vibration and shaft displacement mixing signal in the no-load mode, while the frequency domain was wide without an obvious main frequency in pressure fluctuation mixing signal. Besides, the SSTκ-ω turbulence model was adopted to simulate the four quadrant characteristic curves of Baoquan model pump-turbine at three gate openings, and the relative error between simulation results and model test data was within ±6%, indicating that the simulation method in this paper is feasible and S-shaped characteristic of the pump-turbine can be simulated with CFD method.