In this paper, design and construction of a modified cold molybdenum cathode Penning ion source was described. It consists of copper cylindrical anode with two cone ends and two movable cold molybdenum cathodes. The t...In this paper, design and construction of a modified cold molybdenum cathode Penning ion source was described. It consists of copper cylindrical anode with two cone ends and two movable cold molybdenum cathodes. The two cathodes were placed symmetrically at two ends of the anode. The modifications were decrease the length of the cylindrical anode to 4 cm instead of 6 cm, transform the copper emission electrode shape from plate of 40 mm length, 25 mm width and 2 mm thickness to disc of 20 mm diameter and 2 mm thickness and transform the inner uncovered area of the emission electrode from slit of 30 mm length and 10 mm width to disc of 5 mm diameter. The copper emission electrode was placed in the middle of the cylindrical anode and has aperture in the center of different diameters. Faraday cup was placed at different distances from the emission electrode aperture. The electrical discharge and the output ion beam characteristics of the modified ion source were measured at different pressures using argon gas. It was found that the optimum operating conditions of the modified ion source are; anode-cathode distance equal to 6 mm, emission electrode aperture diameter equal to 2.5 mm and emission electrode aperture, Faraday cup distance equals 3 cm. The effect of axial samarium cobalt permanent magnet of intensity equal to 300 Gauss on the discharge characteristics of the ion source was determined.展开更多
文摘In this paper, design and construction of a modified cold molybdenum cathode Penning ion source was described. It consists of copper cylindrical anode with two cone ends and two movable cold molybdenum cathodes. The two cathodes were placed symmetrically at two ends of the anode. The modifications were decrease the length of the cylindrical anode to 4 cm instead of 6 cm, transform the copper emission electrode shape from plate of 40 mm length, 25 mm width and 2 mm thickness to disc of 20 mm diameter and 2 mm thickness and transform the inner uncovered area of the emission electrode from slit of 30 mm length and 10 mm width to disc of 5 mm diameter. The copper emission electrode was placed in the middle of the cylindrical anode and has aperture in the center of different diameters. Faraday cup was placed at different distances from the emission electrode aperture. The electrical discharge and the output ion beam characteristics of the modified ion source were measured at different pressures using argon gas. It was found that the optimum operating conditions of the modified ion source are; anode-cathode distance equal to 6 mm, emission electrode aperture diameter equal to 2.5 mm and emission electrode aperture, Faraday cup distance equals 3 cm. The effect of axial samarium cobalt permanent magnet of intensity equal to 300 Gauss on the discharge characteristics of the ion source was determined.