The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t...The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%.展开更多
Three-dimensional transient numerical simulation of gas exchange process in a four-stroke motorcycle engine with a semi-spherical combustion chamber with two tilt valves was studied. Combination of the grid re-meshing...Three-dimensional transient numerical simulation of gas exchange process in a four-stroke motorcycle engine with a semi-spherical combustion chamber with two tilt valves was studied. Combination of the grid re-meshing method and the snapper technique made the valves move smoothly. The flow structure and pattern in a complete engine cycle were described in detail. Tumble ratios around the x-axis and y-axis were analyzed. Comparison of computed pressure with experimental pressure under motored condition revealed that the simulation had high calculation precision; CFD simulation can be regarded as an im-portant tool for resolving the complex aerodynamic behavior in motorcycle engines.展开更多
Currently, the elastic interconnection has realized the high-rate data transmission among data centers(DCs). Thus, the elastic data center network(EDCN) emerged. In EDCNs, it is essential to achieve the virtual networ...Currently, the elastic interconnection has realized the high-rate data transmission among data centers(DCs). Thus, the elastic data center network(EDCN) emerged. In EDCNs, it is essential to achieve the virtual network(VN) embedding, which includes two main components: VM(virtual machine) mapping and VL(virtual link) mapping. In VM mapping, we allocate appropriate servers to hold VMs. While for VL mapping,an optimal substrate path is determined for each virtual lightpath. For the VN embedding in EDCNs, the power efficiency is a significant concern, and some solutions were proposed through sleeping light-duty servers.However, the increasing communication traffic between VMs leads to a serious energy dissipation problem, since it also consumes a great amount of energy on switches even utilizing the energy-efficient optical transmission technique. In this paper, considering load balancing and power-efficient VN embedding, we formulate the problem and design a novel heuristic for EDCNs, with the objective to achieve the power savings of servers and switches. In our solution, VMs are mapped into a single DC or multiple DCs with the short distance between each other, and the servers in the same cluster or adjacent clusters are preferred to hold VMs. Such that, a large amount of servers and switches will become vacant and can go into sleep mode. Simulation results demonstrate that our method performs well in terms of power savings and load balancing. Compared with benchmarks, the improvement ratio of power efficiency is 5%–13%.展开更多
文摘The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%.
文摘Three-dimensional transient numerical simulation of gas exchange process in a four-stroke motorcycle engine with a semi-spherical combustion chamber with two tilt valves was studied. Combination of the grid re-meshing method and the snapper technique made the valves move smoothly. The flow structure and pattern in a complete engine cycle were described in detail. Tumble ratios around the x-axis and y-axis were analyzed. Comparison of computed pressure with experimental pressure under motored condition revealed that the simulation had high calculation precision; CFD simulation can be regarded as an im-portant tool for resolving the complex aerodynamic behavior in motorcycle engines.
基金supported in part by Open Foundation of State Key Laboratory of Information Photonics and Optical Communications (Grant No. IPOC2014B009)Fundamental Research Funds for the Central Universities (Grant Nos. N130817002, N140405005, N150401002)+3 种基金Foundation of the Education Department of Liaoning Province (Grant No. L2014089)National Natural Science Foundation of China (Grant Nos. 61302070, 61401082, 61471109, 61502075)Liaoning Bai Qian Wan Talents ProgramNational High-Level Personnel Special Support Program for Youth Top-Notch Talent
文摘Currently, the elastic interconnection has realized the high-rate data transmission among data centers(DCs). Thus, the elastic data center network(EDCN) emerged. In EDCNs, it is essential to achieve the virtual network(VN) embedding, which includes two main components: VM(virtual machine) mapping and VL(virtual link) mapping. In VM mapping, we allocate appropriate servers to hold VMs. While for VL mapping,an optimal substrate path is determined for each virtual lightpath. For the VN embedding in EDCNs, the power efficiency is a significant concern, and some solutions were proposed through sleeping light-duty servers.However, the increasing communication traffic between VMs leads to a serious energy dissipation problem, since it also consumes a great amount of energy on switches even utilizing the energy-efficient optical transmission technique. In this paper, considering load balancing and power-efficient VN embedding, we formulate the problem and design a novel heuristic for EDCNs, with the objective to achieve the power savings of servers and switches. In our solution, VMs are mapped into a single DC or multiple DCs with the short distance between each other, and the servers in the same cluster or adjacent clusters are preferred to hold VMs. Such that, a large amount of servers and switches will become vacant and can go into sleep mode. Simulation results demonstrate that our method performs well in terms of power savings and load balancing. Compared with benchmarks, the improvement ratio of power efficiency is 5%–13%.