The flow field of liquid phase (water) of agitated extraction columns is simulated with the help of computational fluid dynamics (CFD). Four kinds of Reynolds-averaged turbulence models, i.e. the standard k-ε model, ...The flow field of liquid phase (water) of agitated extraction columns is simulated with the help of computational fluid dynamics (CFD). Four kinds of Reynolds-averaged turbulence models, i.e. the standard k-ε model, the RNG (renormalization group) k-s model, the realizable k-ε model and the Reynolds stress model, are compared in detail in order to judge which is the best model in terms of the accuracy, less CPU time and memory required. The performance of the realizable k-s model is obviously improved by reducing the model constant from C2 = 1.90 to C2 = 1.61. It is concluded that the improved realizable k-e model is the optimal model.展开更多
Improved fluid dynamics can enhance the separation efficiency of flotation methods. A Computational Fluid Dynamics simulation using FLUENT was performed to model the fluid environment of a cyclonic-sta- tic micro bubb...Improved fluid dynamics can enhance the separation efficiency of flotation methods. A Computational Fluid Dynamics simulation using FLUENT was performed to model the fluid environment of a cyclonic-sta- tic micro bubble flotation column. The simulation results visually show the interior flow and illustrate mix- ing of the different flows within the apparatus. An analysis of the distribution in velocity and vorticity was used to analyze the separation mechanism and the synergism of the component parts and to strengthen the design of each unit. The conclusions are that axial back mixing and vortexes still exist in the separation unit even in the presence of packing media. The inverted cone structure near the tangential inlet (cone 1 ) within the cyclonic unit is the main reason for this. The cone 1 structure enhances swirling and focuses energy within the inner area of the cone where there are abundant bubbles. As a result slowly floating minerals are forcibly recovered and railings are effectively separated within this unit. However, cone 1 also reduces the vorticity downstream from it, which reduces the efficiency of railings separation within this part. Therefore, the design of cone 1 should be based on the principles of lessening disturbances to the column unit while strengthening the separation effect of the cyclonic unit. Also, the axial distance between the paired cyclonic structures at the bottom of the column (cone 2) and cone 1 poses tough requirements because of an interaction between separation of the middlings and railings.展开更多
Numerical simulation of transient mass transfer to a single dropcontrolled by the internal resistance or by the resistance in bothphases was mathematically formulated and simulated in aboundary-fitted orthogonal coord...Numerical simulation of transient mass transfer to a single dropcontrolled by the internal resistance or by the resistance in bothphases was mathematically formulated and simulated in aboundary-fitted orthogonal coordinate system. The simulated resultson the transient mass transfer dominated by the internal resistanceare in good agreement with the Newman and Kronig-Brink models fordrops with low Reynolds number. When the drop Reynolds number is upto 200, the mass transfer coefficient from numerical simulation isvery low as compared with The Handlos-Baron model.展开更多
There are three well known types of wire lines for transmitting electrical energy or information. The first type is ordinary two wires line (below A-Line). The second type is so-called single-wire line, where ground...There are three well known types of wire lines for transmitting electrical energy or information. The first type is ordinary two wires line (below A-Line). The second type is so-called single-wire line, where ground plays the role instead of second wire. Polyphase systems belong to the third type, three phase system is the most popular among them. The purpose of this article is another attempt to build a one-wired (without ground) system--the transmission of electrical energy. In this paper an original idea of building such a system is justified, the results of simulations and laboratory modeling are presented. It is shown that the proposed method can reduce the cost of electric transmission lines, the losses in them and significantly reduce interferences.展开更多
文摘The flow field of liquid phase (water) of agitated extraction columns is simulated with the help of computational fluid dynamics (CFD). Four kinds of Reynolds-averaged turbulence models, i.e. the standard k-ε model, the RNG (renormalization group) k-s model, the realizable k-ε model and the Reynolds stress model, are compared in detail in order to judge which is the best model in terms of the accuracy, less CPU time and memory required. The performance of the realizable k-s model is obviously improved by reducing the model constant from C2 = 1.90 to C2 = 1.61. It is concluded that the improved realizable k-e model is the optimal model.
基金supported by the National Natural Science Foundation of China (No. 51074157)the Foundation of China University of Mining and Technology (No. 2011QNA08)
文摘Improved fluid dynamics can enhance the separation efficiency of flotation methods. A Computational Fluid Dynamics simulation using FLUENT was performed to model the fluid environment of a cyclonic-sta- tic micro bubble flotation column. The simulation results visually show the interior flow and illustrate mix- ing of the different flows within the apparatus. An analysis of the distribution in velocity and vorticity was used to analyze the separation mechanism and the synergism of the component parts and to strengthen the design of each unit. The conclusions are that axial back mixing and vortexes still exist in the separation unit even in the presence of packing media. The inverted cone structure near the tangential inlet (cone 1 ) within the cyclonic unit is the main reason for this. The cone 1 structure enhances swirling and focuses energy within the inner area of the cone where there are abundant bubbles. As a result slowly floating minerals are forcibly recovered and railings are effectively separated within this unit. However, cone 1 also reduces the vorticity downstream from it, which reduces the efficiency of railings separation within this part. Therefore, the design of cone 1 should be based on the principles of lessening disturbances to the column unit while strengthening the separation effect of the cyclonic unit. Also, the axial distance between the paired cyclonic structures at the bottom of the column (cone 2) and cone 1 poses tough requirements because of an interaction between separation of the middlings and railings.
基金Supported by the National Natural Science Foundation of China (No. 29792074, No. 29836130} and SINOPEC.
文摘Numerical simulation of transient mass transfer to a single dropcontrolled by the internal resistance or by the resistance in bothphases was mathematically formulated and simulated in aboundary-fitted orthogonal coordinate system. The simulated resultson the transient mass transfer dominated by the internal resistanceare in good agreement with the Newman and Kronig-Brink models fordrops with low Reynolds number. When the drop Reynolds number is upto 200, the mass transfer coefficient from numerical simulation isvery low as compared with The Handlos-Baron model.
文摘There are three well known types of wire lines for transmitting electrical energy or information. The first type is ordinary two wires line (below A-Line). The second type is so-called single-wire line, where ground plays the role instead of second wire. Polyphase systems belong to the third type, three phase system is the most popular among them. The purpose of this article is another attempt to build a one-wired (without ground) system--the transmission of electrical energy. In this paper an original idea of building such a system is justified, the results of simulations and laboratory modeling are presented. It is shown that the proposed method can reduce the cost of electric transmission lines, the losses in them and significantly reduce interferences.