According to the characteristics of ecosystem and concept of the ecosystem in mining area, the index system of the ecosystem health in mining area was set up, and the evaluation standard was established. Aiming at the...According to the characteristics of ecosystem and concept of the ecosystem in mining area, the index system of the ecosystem health in mining area was set up, and the evaluation standard was established. Aiming at the complexion in which the information lost in index ration, the matter element method was put forward to evaluate the ecosystem health in mining area. Making use of the model set up, the weight was built up by the method of index number heavy, the matter element, clas- sical field, and limit field were set up. The rating hierarchy was calculated by relating function. As a case study in the mining area of Pingyangsi Town, the results show that the ecosystem is good and sustainable from 2003 to 2006, but the healthy degree is not high, and some indexes have depravation.展开更多
There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R4...There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.展开更多
Slow trends in the RR interval(RRI) series should be removed in the preprocessing step to get a reliable result of heart rate variability(HRV) analysis. Re-sampling is required to convert the unevenly sampled RRI seri...Slow trends in the RR interval(RRI) series should be removed in the preprocessing step to get a reliable result of heart rate variability(HRV) analysis. Re-sampling is required to convert the unevenly sampled RRI series into evenly sampled time series when using the widely accepted smoothness priors approach(SPA). Noise is introduced in this process and the information quality is thus compromised. Empirical mode decomposition(EMD) and its variants, were introduced to directly process the unevenly sampled RRI series. Besides, a RR interval model was proposed to fascinate the introduction of standard metrics for the evaluation of the detrending performance. Based on standard metrics including signal-to-noise-ratio in d B(ISNR), mean square error(EMS), and percent root square difference(DPRS), the effectiveness of detrending methods in RR interval analysis were determined. Results demonstrate that complementary ensemble EMD(CEEMD, a variant of EMD) based method has a higher ISNR, a lower EMS and a lower DPRS as well as a better RRI series detrending performance compared with the SPA method, which would in turn lead to a more accurate HRV analysis.展开更多
It is well known that the Poincaré gauge theories of gravity do not have the structure of a standard gauge theory. Nevertheless, we show that a general form of action for the gravitational gauge fields in the gau...It is well known that the Poincaré gauge theories of gravity do not have the structure of a standard gauge theory. Nevertheless, we show that a general form of action for the gravitational gauge fields in the gauge theory does possess local Poincaré invariance.展开更多
Energy Management System (EnMS), benefiting enterprises with energy conservation through the PDCA cycle, has been widely valued and applied by domestic and overseas enterprises. Based on the experience on the constr...Energy Management System (EnMS), benefiting enterprises with energy conservation through the PDCA cycle, has been widely valued and applied by domestic and overseas enterprises. Based on the experience on the construction and implementation of energy management system, the paper systematically analyzes the construction ideas and development requirements of EnMS standards system, aiming to broaden/he coverage of EnMS and its technical indicator system, strengthen the systematicness and comprehensiveness and provide standardized tools and methods for all users.展开更多
Environmental protection products and equipment are important substance basis and insurance which provide supporting for to the realization of the strategic objective of reduced energy use and emissions while improvin...Environmental protection products and equipment are important substance basis and insurance which provide supporting for to the realization of the strategic objective of reduced energy use and emissions while improving the resource economy & environmental kindly society building, as well as the sustainable development economy and environment in a sustainable fashion. Here, the framework of the standards system and evaluation indicators system for environmental protection products are described based on the present deficiencies in independent innovation, lower levels of standardization, and poor operating effectiveness of such equipment in China with a goal of forcing the development of standardization, seriation and currency used in the environmental protection industry. The results presented here should serve as a reference for the promotion of quality and effectiveness in environmental protection products and equipments.展开更多
The acute toxicity data of Cr+ and Hg2+ to the aquatic organisms in Liao River basin was collected and screened. Calculated results of criteria values using popular species sensitivity distribution (SSD) methods w...The acute toxicity data of Cr+ and Hg2+ to the aquatic organisms in Liao River basin was collected and screened. Calculated results of criteria values using popular species sensitivity distribution (SSD) methods were evaluated through data analysis. The comprehensive methodology of emergency water quality standards (EWQSs) was established on the basis of the SSD method of Australia and New Zealand according to the evalu- ation results. The affected fractions of the aquatic organisms were set to be 5 %, 15 %, 30 % and 50 %, corre- sponding to the risk grades of Ⅰ,Ⅱ,Ⅲ and IV, and four-grade EWQSs, respectively. The EWQSs for Cr6+ and Hg2. in the Liao River were derived and the corresponding risk indicators were also proposed. The results showed that the four-grade EWQSs for Cr6+ were 2.85 μg/L, 21.0 μg/L, 161 μg/L and 797 μ/L, respec- tively, and the risk indicators were daphnia (grade Ⅱ ), shrimp (grade Ⅲ), and the bighead fish or tadpole (grade IV). The four-grade EWQSs for Hg2+ were 0.59 μg/L, 2.32 μg/L, 6.25 μg/L and 15.6 μg/L, respective- ly, and the risk indicators were crucian carp or daphnia (grade Ⅱ), shrimp (grade Ⅲ), and worm or crab (grade IV). The results provided valuable information for the risk analysis of sudden ambient water environmen- tal pollution accident.展开更多
This paper discusses the methods of establishing risk criteria for dams and reviews the application of dam risk criteria for individuals and societies in different countries or districts. Given the conditions in China...This paper discusses the methods of establishing risk criteria for dams and reviews the application of dam risk criteria for individuals and societies in different countries or districts. Given the conditions in China and considering the public safety and acceptance of dam risk, historical dam break data and current design standards, individual and societal risk criteria for dams are proposed. The tolerable dam risk criteria for individuals should be set to 10-5-10-7 per annum based on project scale, for ex- ample, approximately 1.0xl0 7 per annum, which corresponds to a reliability index of 4.2 based on a 100-year lifespan for a first-class or large project. The societal limit for risk tolerance for dams should be set to approximately 10-3-10-5 per annum, corresponding to the fatality range from 1 to 100 and be horizontally extended to 1000, and F-N curves are proposed. It was also found that the reliability indices of Chinese Standard (GB 50199-2013) and Eurocodel (2002) are different, but they have the same level of safety measured by the annual probability of failure. The research results have significance for establishing dam risk criteria.展开更多
Over the past ten years, China has seen a number of practices exploring the evaluation of the rule of law. It is important that we sum up the practical experience of these evaluations, analyze the problems they encoun...Over the past ten years, China has seen a number of practices exploring the evaluation of the rule of law. It is important that we sum up the practical experience of these evaluations, analyze the problems they encounter, determine their direction nationwide, and put forward constructive ideas. With the issuing of the Decision of the Central Committee of the CPC on Some Major Issues Concerning Comprehensively Deepening the Reform and the Decision of the Central Committee of the CPC on Promoting a Number of Major Issues of the Rule of Law, evaluation of the rule of law faces a transformation both in theory and in practice. The key points in this transformation are having the right orientation, innovative mechanisms and solutions to tricky issues of quantitative evaluation; summing up evaluation of experience; and elevating evaluation to the level of theory. A precondition for its effective evaluation is a scientific mechanism for evaluating the rule of law; in turn, the key to a scientific evaluation is solving the problems in quantitative evaluation of the rule of law; and the necessary requirements for evaluation practice are summing up evaluation experience and elevating it to the level of theory. The key to innovative mechanisms for evaluating the rule of law lies in implementation of the third party evaluation model and in quantitative evaluation that starts with particular programs.展开更多
文摘According to the characteristics of ecosystem and concept of the ecosystem in mining area, the index system of the ecosystem health in mining area was set up, and the evaluation standard was established. Aiming at the complexion in which the information lost in index ration, the matter element method was put forward to evaluate the ecosystem health in mining area. Making use of the model set up, the weight was built up by the method of index number heavy, the matter element, clas- sical field, and limit field were set up. The rating hierarchy was calculated by relating function. As a case study in the mining area of Pingyangsi Town, the results show that the ecosystem is good and sustainable from 2003 to 2006, but the healthy degree is not high, and some indexes have depravation.
文摘There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.
基金Project(41227803)supported by the National Natural Science Foundation of ChinaProject(KF11011)supported by the State Key Laboratory of Automotive Safety and Energy(Tsinghua University),ChinaProject(DTNH22-08-C-00082)supported by the National Highway Traffic Safety Administration,USA
文摘Slow trends in the RR interval(RRI) series should be removed in the preprocessing step to get a reliable result of heart rate variability(HRV) analysis. Re-sampling is required to convert the unevenly sampled RRI series into evenly sampled time series when using the widely accepted smoothness priors approach(SPA). Noise is introduced in this process and the information quality is thus compromised. Empirical mode decomposition(EMD) and its variants, were introduced to directly process the unevenly sampled RRI series. Besides, a RR interval model was proposed to fascinate the introduction of standard metrics for the evaluation of the detrending performance. Based on standard metrics including signal-to-noise-ratio in d B(ISNR), mean square error(EMS), and percent root square difference(DPRS), the effectiveness of detrending methods in RR interval analysis were determined. Results demonstrate that complementary ensemble EMD(CEEMD, a variant of EMD) based method has a higher ISNR, a lower EMS and a lower DPRS as well as a better RRI series detrending performance compared with the SPA method, which would in turn lead to a more accurate HRV analysis.
基金supported by National Natural Science Foundation of China under Grant No.10675019
文摘It is well known that the Poincaré gauge theories of gravity do not have the structure of a standard gauge theory. Nevertheless, we show that a general form of action for the gravitational gauge fields in the gauge theory does possess local Poincaré invariance.
文摘Energy Management System (EnMS), benefiting enterprises with energy conservation through the PDCA cycle, has been widely valued and applied by domestic and overseas enterprises. Based on the experience on the construction and implementation of energy management system, the paper systematically analyzes the construction ideas and development requirements of EnMS standards system, aiming to broaden/he coverage of EnMS and its technical indicator system, strengthen the systematicness and comprehensiveness and provide standardized tools and methods for all users.
文摘Environmental protection products and equipment are important substance basis and insurance which provide supporting for to the realization of the strategic objective of reduced energy use and emissions while improving the resource economy & environmental kindly society building, as well as the sustainable development economy and environment in a sustainable fashion. Here, the framework of the standards system and evaluation indicators system for environmental protection products are described based on the present deficiencies in independent innovation, lower levels of standardization, and poor operating effectiveness of such equipment in China with a goal of forcing the development of standardization, seriation and currency used in the environmental protection industry. The results presented here should serve as a reference for the promotion of quality and effectiveness in environmental protection products and equipments.
基金National Major Programme of Water Pollution Control and Treatment(No.2012ZX07501003-06)
文摘The acute toxicity data of Cr+ and Hg2+ to the aquatic organisms in Liao River basin was collected and screened. Calculated results of criteria values using popular species sensitivity distribution (SSD) methods were evaluated through data analysis. The comprehensive methodology of emergency water quality standards (EWQSs) was established on the basis of the SSD method of Australia and New Zealand according to the evalu- ation results. The affected fractions of the aquatic organisms were set to be 5 %, 15 %, 30 % and 50 %, corre- sponding to the risk grades of Ⅰ,Ⅱ,Ⅲ and IV, and four-grade EWQSs, respectively. The EWQSs for Cr6+ and Hg2. in the Liao River were derived and the corresponding risk indicators were also proposed. The results showed that the four-grade EWQSs for Cr6+ were 2.85 μg/L, 21.0 μg/L, 161 μg/L and 797 μ/L, respec- tively, and the risk indicators were daphnia (grade Ⅱ ), shrimp (grade Ⅲ), and the bighead fish or tadpole (grade IV). The four-grade EWQSs for Hg2+ were 0.59 μg/L, 2.32 μg/L, 6.25 μg/L and 15.6 μg/L, respective- ly, and the risk indicators were crucian carp or daphnia (grade Ⅱ), shrimp (grade Ⅲ), and worm or crab (grade IV). The results provided valuable information for the risk analysis of sudden ambient water environmen- tal pollution accident.
基金supported by the National Key Basic Research Program of China(Grant No.2013CB036403)
文摘This paper discusses the methods of establishing risk criteria for dams and reviews the application of dam risk criteria for individuals and societies in different countries or districts. Given the conditions in China and considering the public safety and acceptance of dam risk, historical dam break data and current design standards, individual and societal risk criteria for dams are proposed. The tolerable dam risk criteria for individuals should be set to 10-5-10-7 per annum based on project scale, for ex- ample, approximately 1.0xl0 7 per annum, which corresponds to a reliability index of 4.2 based on a 100-year lifespan for a first-class or large project. The societal limit for risk tolerance for dams should be set to approximately 10-3-10-5 per annum, corresponding to the fatality range from 1 to 100 and be horizontally extended to 1000, and F-N curves are proposed. It was also found that the reliability indices of Chinese Standard (GB 50199-2013) and Eurocodel (2002) are different, but they have the same level of safety measured by the annual probability of failure. The research results have significance for establishing dam risk criteria.
文摘Over the past ten years, China has seen a number of practices exploring the evaluation of the rule of law. It is important that we sum up the practical experience of these evaluations, analyze the problems they encounter, determine their direction nationwide, and put forward constructive ideas. With the issuing of the Decision of the Central Committee of the CPC on Some Major Issues Concerning Comprehensively Deepening the Reform and the Decision of the Central Committee of the CPC on Promoting a Number of Major Issues of the Rule of Law, evaluation of the rule of law faces a transformation both in theory and in practice. The key points in this transformation are having the right orientation, innovative mechanisms and solutions to tricky issues of quantitative evaluation; summing up evaluation of experience; and elevating evaluation to the level of theory. A precondition for its effective evaluation is a scientific mechanism for evaluating the rule of law; in turn, the key to a scientific evaluation is solving the problems in quantitative evaluation of the rule of law; and the necessary requirements for evaluation practice are summing up evaluation experience and elevating it to the level of theory. The key to innovative mechanisms for evaluating the rule of law lies in implementation of the third party evaluation model and in quantitative evaluation that starts with particular programs.