It is important to remove the impurities, such as copper and cadmium, from leaching solution in zinc hydrometallurgy. To improve purification efficiency, a replacement-column purification device was proposed and its m...It is important to remove the impurities, such as copper and cadmium, from leaching solution in zinc hydrometallurgy. To improve purification efficiency, a replacement-column purification device was proposed and its mass transfer characteristics and purification efficiency were experimentally studied. The results show that purification efficiency increases with the decrease of the zinc powder diameter and decreases with the increase of solution velocity. If appropriate structure and operation parameters are used, it is possible to make purification efficiency more than 99%, but the diameter of zinc powder should be larger than 0.45 mm. For the velocity of 0.05-0.7 cm/s, mass transfer coefficient kc is in the range of 3.94×10-7-2.76×10-6 m/s, and increases with the decrease of zinc powder diameter and the increase of solution velocity. Moreover, it can be derived by mass transfer correlations of Sherwood number:Sh=0.1069Re0.5Sc0.33, for 0.3<Re<6.展开更多
High performance liquid chromatography with column switching has been developed for the determination of lansoprazole in plasma. The plasma samples were injected onto a pretreatment column packed with LiChromprep RP2 ...High performance liquid chromatography with column switching has been developed for the determination of lansoprazole in plasma. The plasma samples were injected onto a pretreatment column packed with LiChromprep RP2 (25~40 mm) after simple dilution with distilled water. Distilled water was used to wash out protein and other polar components in plasma. After switching, the concentrated lansoprazole was eluted in the backflush mode onto a Shimpack CLC ODS column with methanol 0 2 mol·L 1 ammonium acetate (65:35) as mobile phase. Purge solutions were used for clean up and for regenerating the pretreatment column. The method showed good precision and recovery. The detection limit was 0 005 mg·L -1 plasma. The RSD’s (intra and interday) were less than 2 5% and 5 3% respectively. The method has been successfully used to determine pharmacokinetics of lansoprazole in Chinese volunteers.展开更多
基金Project(Y2010-1-005)supported by the Collaborative Fund of Hunan Nonferrous Metals Holding Group-Central South University,China
文摘It is important to remove the impurities, such as copper and cadmium, from leaching solution in zinc hydrometallurgy. To improve purification efficiency, a replacement-column purification device was proposed and its mass transfer characteristics and purification efficiency were experimentally studied. The results show that purification efficiency increases with the decrease of the zinc powder diameter and decreases with the increase of solution velocity. If appropriate structure and operation parameters are used, it is possible to make purification efficiency more than 99%, but the diameter of zinc powder should be larger than 0.45 mm. For the velocity of 0.05-0.7 cm/s, mass transfer coefficient kc is in the range of 3.94×10-7-2.76×10-6 m/s, and increases with the decrease of zinc powder diameter and the increase of solution velocity. Moreover, it can be derived by mass transfer correlations of Sherwood number:Sh=0.1069Re0.5Sc0.33, for 0.3<Re<6.
文摘High performance liquid chromatography with column switching has been developed for the determination of lansoprazole in plasma. The plasma samples were injected onto a pretreatment column packed with LiChromprep RP2 (25~40 mm) after simple dilution with distilled water. Distilled water was used to wash out protein and other polar components in plasma. After switching, the concentrated lansoprazole was eluted in the backflush mode onto a Shimpack CLC ODS column with methanol 0 2 mol·L 1 ammonium acetate (65:35) as mobile phase. Purge solutions were used for clean up and for regenerating the pretreatment column. The method showed good precision and recovery. The detection limit was 0 005 mg·L -1 plasma. The RSD’s (intra and interday) were less than 2 5% and 5 3% respectively. The method has been successfully used to determine pharmacokinetics of lansoprazole in Chinese volunteers.