For the characteristics of the continuous stirred-tank reactor(CSTR) with coil and jacket cooling system,a CSTR temperature dual control solution based on the analysis of the CSTR exothermic reaction control character...For the characteristics of the continuous stirred-tank reactor(CSTR) with coil and jacket cooling system,a CSTR temperature dual control solution based on the analysis of the CSTR exothermic reaction control characteristic was proposed for an organic material polymerization production.The control solution has passive fault-tolerant ability for the jacket cooling water cutting off fault and active fault-tolerant potential for the coil cooling water cutting off fault,and it has good control ability,high saving energy and reducing consumption performance.Fault detection and diagnosis and fault-tolerant control strategy are designed for the coil cooling fault to achieve the active fault-tolerant control function.The CSTR temperature dual control,process fault detection and diagnosis and active fault-tolerant control were full integrated into the CSTR temperature fault-tolerant control system,which achieve fault tolerance control of CSTR temperature for any severe malfunction of jacket cooling or coil cooling cutting off,and the security for CSTR exothermic reaction is improved.Finally,the effectiveness of this system was validated by semi-physical simulation experiment.展开更多
This work presents results on the commissioning of the new heat exchanger of the IEA-R1 nuclear reactor in the occasion of its operational power upgrade from 2 MW to 5 MW, in comparison to the values calculated in the...This work presents results on the commissioning of the new heat exchanger of the IEA-R1 nuclear reactor in the occasion of its operational power upgrade from 2 MW to 5 MW, in comparison to the values calculated in the project of IESA Design and Equipments Company. This reactor is a swimming pool type, light water moderated and with graphite reflectors, used for research purposes and medical radioisotopes production. During monitoring procedures, issues were observed on the reactor operation at 5 MW mainly due to the ageing of the reactor's oldest heat exchanger (TC-A) and excessive vibrations at high flow rates on the other installed heat exchanger (TC-B). So it was decided to provide a new IESA heat exchanger with 5 MW capacity to definitely substitute the TC-A heat exchanger. The results show that the IEA-R1 nuclear reactor can be operated safely and continuously at 5 MW with the new IESA heat exchanger.展开更多
基金Project(2013JM8024)Supported by Natural Science Basic Research Plan in Shaanxi Province of China
文摘For the characteristics of the continuous stirred-tank reactor(CSTR) with coil and jacket cooling system,a CSTR temperature dual control solution based on the analysis of the CSTR exothermic reaction control characteristic was proposed for an organic material polymerization production.The control solution has passive fault-tolerant ability for the jacket cooling water cutting off fault and active fault-tolerant potential for the coil cooling water cutting off fault,and it has good control ability,high saving energy and reducing consumption performance.Fault detection and diagnosis and fault-tolerant control strategy are designed for the coil cooling fault to achieve the active fault-tolerant control function.The CSTR temperature dual control,process fault detection and diagnosis and active fault-tolerant control were full integrated into the CSTR temperature fault-tolerant control system,which achieve fault tolerance control of CSTR temperature for any severe malfunction of jacket cooling or coil cooling cutting off,and the security for CSTR exothermic reaction is improved.Finally,the effectiveness of this system was validated by semi-physical simulation experiment.
文摘This work presents results on the commissioning of the new heat exchanger of the IEA-R1 nuclear reactor in the occasion of its operational power upgrade from 2 MW to 5 MW, in comparison to the values calculated in the project of IESA Design and Equipments Company. This reactor is a swimming pool type, light water moderated and with graphite reflectors, used for research purposes and medical radioisotopes production. During monitoring procedures, issues were observed on the reactor operation at 5 MW mainly due to the ageing of the reactor's oldest heat exchanger (TC-A) and excessive vibrations at high flow rates on the other installed heat exchanger (TC-B). So it was decided to provide a new IESA heat exchanger with 5 MW capacity to definitely substitute the TC-A heat exchanger. The results show that the IEA-R1 nuclear reactor can be operated safely and continuously at 5 MW with the new IESA heat exchanger.