期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
管束排列及管间距对换热器传热性能的影响分析 被引量:2
1
作者 唐喜龙 《电子测试》 2018年第10期40-41,共2页
管束排列及管间距是换热器传热性能的重要影响因素。为验证灌输排列及管间距对换热器传热性能的影响。试验人员会以圆形翅片管换热器为研究对象,在对此类换热器的管束排列和管间距进行调整的方式,求取雷诺数、纵向管间距和管换热器的传... 管束排列及管间距是换热器传热性能的重要影响因素。为验证灌输排列及管间距对换热器传热性能的影响。试验人员会以圆形翅片管换热器为研究对象,在对此类换热器的管束排列和管间距进行调整的方式,求取雷诺数、纵向管间距和管换热器的传热性能,并在此基础上,分析管束排列和管间距对换热器传热性能的影响。 展开更多
关键词 灌输排列 管间距 换热器传热性能
下载PDF
Implementation of heat exchanger performance testing system of heat transfer and flow resistance 被引量:3
2
作者 操瑞兵 陈亚平 +2 位作者 吴嘉峰 董聪 盛艳军 《Journal of Southeast University(English Edition)》 EI CAS 2012年第1期46-51,共6页
A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, co... A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, compressed air, glycol water solution and water as the heating fluids, and air and water as the cooling fluids. The heat transfer performance testing of heat exchangers can be conducted not only for a conventional one heating fluid to one cooling fluid, but also for a compound air cooling heat exchanger with two or three heating fluids in parallel or in series. The control and measurement system is implemented based on a LabVIEW software platform, consisting of the data acquisition and process system, and the automotive operation and control system. By using advanced measuring instruments combined with sound computer software control, the testing system has characteristics of a compact structure, high accuracy, a wide range of testing scope and a friendly operation interface. The uncertainty of the total heat transfer coefficient K is less than 5%. The testing system provides a reliable performance testing platform for designing and developing new heat exchangers. 展开更多
关键词 heat exchanger heat transfer performance testing system LABVIEW
下载PDF
Comparison of heat transfer performances of helix baffled heat exchangers with different baffle configurations 被引量:3
3
作者 董聪 陈亚平 吴嘉峰 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第1期255-261,共7页
Numerical simulations were performed on flow and heat transfer performances of heat exchangers having six helical baffles of different baffle shapes and assembly configurations, i.e., two trisection baffle schemes, tw... Numerical simulations were performed on flow and heat transfer performances of heat exchangers having six helical baffles of different baffle shapes and assembly configurations, i.e., two trisection baffle schemes, two quadrant baffle schemes, and two continuous helical baffle schemes. The temperature contour or the pressure contour and velocity contour plots with superimposed velocity vectors on meridian, transverse and unfolded concentric hexagonal slices are presented to obtain a full angular view. For the six helix baffled heat exchangers,the different patterns of the single vortex secondary flow and the shortcut leakage flow were depicted as well as the heat transfer properties were compared. The results show that the optimum scheme among the six configurations is a circumferential overlap trisection helix baffled heat exchanger with a baffle incline angle of 20°(20°TCO) scheme with an anti-shortcut baffle structure, which exhibits the second highest pressure dropΔpo, the highest overall heat transfer coefficient K, shell-side heat transfer coefficient hoand shell-side average comprehensive index ho/Δpo. 展开更多
关键词 Helix baffled heat exchanger Trisection baffle Quadrant baffle Continuous baffle Circumferential overlap baffle Secondary flow Heat transfer Numerical simulation
下载PDF
Effects of Shape and Quantity of Helical Baffle on the Shell-side Heat Transfer and Flow Performance of Heat Exchangers 被引量:6
4
作者 杜文静 王红福 程林 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2014年第3期243-251,共9页
Shape and quantity of helical baffles have great impact on the shell-side performance of helical baffled heat exchangers (HBHE). In this work, three physical models of HBHE with baffles of different shape (trisecti... Shape and quantity of helical baffles have great impact on the shell-side performance of helical baffled heat exchangers (HBHE). In this work, three physical models of HBHE with baffles of different shape (trisection, quadrant and sextant sector) were investigated. Numerical simulations were performed on HBHE at three helix an- gles (10°, 25° and 40°) by the software ANSYS CFX. Analyses of numerical results indicate that the sextant HBHE shows relatively better fluid flow performance because the leakage flow in the triangle area is evidently reduced and the fluid streamline appears much closer to an ideal spiral flow, while the trisection and quadrant HBHE show more scattered and disordered streamline distributions. The convective heat transfer coefficient and pressure drop in three types of HBHE were presented. Further investigations on the shell side performance with different helical baf- fles were implemented by the field synergy theory. Both theoretical and numerical analyses gave support on the re- lations between helical baffle shape and shell-side performance. This paper may provide useful reference for the selection of baffle shade and auantitv in HBHE. 展开更多
关键词 helical baffled heat exchanger trisection QUADRANT SEXTANT field synergy principle
下载PDF
Arrangement Strategy of Ground Heat Exchanger with Groundwater 被引量:4
5
作者 李太禄 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2012年第4期291-297,共7页
The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t... The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%. 展开更多
关键词 ground source heat pump ground heat exchanger GROUNDWATER GEOTHERMICS
下载PDF
Effects of Clearance around Square Pillar in Rectangular Enclosure on Cooling Performance of Pulsating Airflow
6
作者 Takashi Fukue Koichi Hirose +2 位作者 Hidemi Shirakawa Jun Suzuki Yosuke Saga 《Journal of Mechanics Engineering and Automation》 2016年第8期385-391,共7页
This study focuses on a development of heat transfer enhancement techniques using pulsating flow for thermal equipment such as electronic equipment and heat exchangers. In this report, the heat transfer performance of... This study focuses on a development of heat transfer enhancement techniques using pulsating flow for thermal equipment such as electronic equipment and heat exchangers. In this report, the heat transfer performance of the pulsating airflow around the heating pillar mounted in the rectangular enclosure was investigated experimentally while changing the size of the clearance between the enclosure wall and the pillar. The pillar simulates the components mounted in thermal equipment such as fins and electrical components. The rectangular enclosure simulates an enclosure of electronic equipment and heat exchangers. The shape of the cross section of the pillar was square having sides 30 mm. The dimension of the width of the enclosure was changed from 50 mm to 80 mm. It was found that the heat transfer performance of the pulsating airflow became higher than that of the steady flow regardless of the dimension of the clearance. The heat transfer enhancement around heating components by the pulsating flow can be available regardless of the clearance around the components. 展开更多
关键词 Forced convection heat transfer enhancement pulsating flow thermal management.
下载PDF
Experimental study and analysis of a novel multi-media plate heat exchanger 被引量:2
7
作者 SONG JiWei WANG Fei CHENG Lin 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第8期2157-2162,共6页
The experimental study and analysis of a novel multi-media plate heat exchanger were performed in this paper.This novel multi-media plate heat exchanger was self-developed during the process of the investigation and d... The experimental study and analysis of a novel multi-media plate heat exchanger were performed in this paper.This novel multi-media plate heat exchanger was self-developed during the process of the investigation and design of the alpha magnetic spectrometer(AMS) thermal system.The plate of this kind of novel plate heat exchanger is formed by discontinuous structure wave consisting of convex sphere and concave sphere,its heat transfer performance is better than that of the BR1 chevron plate heat exchanger,and its resistance characteristics are superior to those of the normally used 60-degree plate heat exchanger.Furthermore,the mechanism analysis of heat transfer enhancement shows that the spherical wave structure can reduce the local field synergy angle,so as to improve the field synergy degree of velocity vector and temperature gradient vector. 展开更多
关键词 plate heat exchanger spherical wave field synergy
原文传递
Experimental Study of the Airside Performance for Interrupted Fin-and-tube Heat Exchanger with Hydrophilic Coating under Dehumidifying Conditions
8
作者 马小魁 丁国良 张圆明 《Journal of Shanghai Jiaotong university(Science)》 EI 2009年第1期45-51,共7页
The airside heat transfer and friction characteristics of seven interrupted fin-and-tube heat exchangers with hydrophilic coating under dehumidifying conditions are experimented.The effects of number of tube rows,fin ... The airside heat transfer and friction characteristics of seven interrupted fin-and-tube heat exchangers with hydrophilic coating under dehumidifying conditions are experimented.The effects of number of tube rows,fin pitch and inlet relative humidity on airside performance are analyzed.The test results show that the influence of fin pitch on the friction characteristic under dehumidifying conditions is similar to that under dry surface,and the friction factors decrease slightly with the increase of number of tube rows.The heat transfer performance decreases as fin pitch and number of tube rows increases.The heat transfer performance and the friction characteristic are independent of inlet relative humidity.Based on the test results,heat transfer and friction correlations in terms of the Colburn j factor and Fanning f factor,are proposed to describe the airside performance of the interrupted fin geometry with hydrophilic coating under dehumidifying conditions.The correlation of the Colburn j factor gives a mean deviation of 9.7%,while the correlation of the Fanning f factor shows a mean deviation of 7.3%. 展开更多
关键词 interrupted fin dehumidifying conditions hydrophilic coating heat transfer FRICTION
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部