A mathematical model was established for condensation on surfaces of verticalcorrugated plates based on the mechanism of heat transfer enhancement to thin down the liquid filmdue to surface tension effect between corr...A mathematical model was established for condensation on surfaces of verticalcorrugated plates based on the mechanism of heat transfer enhancement to thin down the liquid filmdue to surface tension effect between corrugated plate surfaces and liquid films. The relative heattransfer coefficients of condensation on corrugation plates were calculated in contrast withequivalent vertical plane ones. The heat transfer enhancement effects for the main geometricparameters such as pitch, height, corrugation angle, tilt angle, and fillet radii of corrugationswere analyzed to guide the optimization of corrugation structure for application. A two-scalecorrugation is suggested, which can compromise both the enhanced heat transfer effect and adequatecross section area for flows, and it makes the heat transfer coefficient 1 to 2 times more than thatof an equivalent plane one.展开更多
For efficient utilization of a limited geothermal resource in practical projects,the cycle parameters were comprehensively analyzed by combining with the heat transfer performance of the plate heat exchanger,with a va...For efficient utilization of a limited geothermal resource in practical projects,the cycle parameters were comprehensively analyzed by combining with the heat transfer performance of the plate heat exchanger,with a variation of flowrate of R245 fa.The influence of working fluid flowrate on a 500 W ORC system was investigated.Adjusting the working fluid flowrate to an optimal value results in the most efficient heat transfer and hence the optimal heat transfer parameters of the plate heat exchanger can be determined.Therefore,for the ORC systems,optimal working fluid flowrate should be controlled.Using different temperature hot water as the heat source,it is found that the optimal flowrate increases by 6-10 L/h with 5 ℃ increment of hot water inlet temperature.During experiment,lower degree of superheat of the working fluid at the outlet the plate heat exchanger may lead to unstable power generation.It is considered that the plate heat exchanger has a compact construction which makes its bulk so small that liquid mixture causes the unstable power generation.To avoid this phenomenon,the flow area of plate heat exchanger should be larger than the designed one.Alternatively,installing a small shell and tube heat exchanger between the outlet of plate heat exchanger and the inlet of expander can be another solution.展开更多
The paper presents a general distributed model of a vertical U-tube direct expansion heat exchanger coupled with the ground. This model is developed for studying the dynamic thermal behavior of a buried heat exchanger...The paper presents a general distributed model of a vertical U-tube direct expansion heat exchanger coupled with the ground. This model is developed for studying the dynamic thermal behavior of a buried heat exchanger which is an integral part of a so-called direct expansion heat pump. The transient conservative equations of mass, momentum and energy considering single and two-phase flow of refrigerant are derived and presented. The diffusive heat exchange with the ground is treated using an analytical approach to treat short-time scale response of vertical boreholes based on an imposed temperature. The thermal interference between the two pipes of the heat exchanger is also considered. The mathematical equations of the model are numerically presented using a control volume formulation and the solution of the system of equations is obtained by successive iterations. The dynamic behavior of the evaporator is simulated and the numerical results are analyzed regarding spatial parameters distribution and thermal interference influence.展开更多
文摘A mathematical model was established for condensation on surfaces of verticalcorrugated plates based on the mechanism of heat transfer enhancement to thin down the liquid filmdue to surface tension effect between corrugated plate surfaces and liquid films. The relative heattransfer coefficients of condensation on corrugation plates were calculated in contrast withequivalent vertical plane ones. The heat transfer enhancement effects for the main geometricparameters such as pitch, height, corrugation angle, tilt angle, and fillet radii of corrugationswere analyzed to guide the optimization of corrugation structure for application. A two-scalecorrugation is suggested, which can compromise both the enhanced heat transfer effect and adequatecross section area for flows, and it makes the heat transfer coefficient 1 to 2 times more than thatof an equivalent plane one.
基金Project (2012AA053001) supported by High-tech Research and Development Program of China
文摘For efficient utilization of a limited geothermal resource in practical projects,the cycle parameters were comprehensively analyzed by combining with the heat transfer performance of the plate heat exchanger,with a variation of flowrate of R245 fa.The influence of working fluid flowrate on a 500 W ORC system was investigated.Adjusting the working fluid flowrate to an optimal value results in the most efficient heat transfer and hence the optimal heat transfer parameters of the plate heat exchanger can be determined.Therefore,for the ORC systems,optimal working fluid flowrate should be controlled.Using different temperature hot water as the heat source,it is found that the optimal flowrate increases by 6-10 L/h with 5 ℃ increment of hot water inlet temperature.During experiment,lower degree of superheat of the working fluid at the outlet the plate heat exchanger may lead to unstable power generation.It is considered that the plate heat exchanger has a compact construction which makes its bulk so small that liquid mixture causes the unstable power generation.To avoid this phenomenon,the flow area of plate heat exchanger should be larger than the designed one.Alternatively,installing a small shell and tube heat exchanger between the outlet of plate heat exchanger and the inlet of expander can be another solution.
文摘The paper presents a general distributed model of a vertical U-tube direct expansion heat exchanger coupled with the ground. This model is developed for studying the dynamic thermal behavior of a buried heat exchanger which is an integral part of a so-called direct expansion heat pump. The transient conservative equations of mass, momentum and energy considering single and two-phase flow of refrigerant are derived and presented. The diffusive heat exchange with the ground is treated using an analytical approach to treat short-time scale response of vertical boreholes based on an imposed temperature. The thermal interference between the two pipes of the heat exchanger is also considered. The mathematical equations of the model are numerically presented using a control volume formulation and the solution of the system of equations is obtained by successive iterations. The dynamic behavior of the evaporator is simulated and the numerical results are analyzed regarding spatial parameters distribution and thermal interference influence.