Heat transfer enhancement is used in many applications including heat exchangers, air conditioning, and refrigeration systems; hence many researchers have conducted experimental and numerical researches on heat transf...Heat transfer enhancement is used in many applications including heat exchangers, air conditioning, and refrigeration systems; hence many researchers have conducted experimental and numerical researches on heat transfer enhancement and have developed various techniques and methods. As a passive heat transfer technique, twisted tapes are widely used in various industries for their cost savings, lower maintenance requirements and the fact that they are easily set up. This paper introduces the principle of heat transfer enhancement of twisted tapes and reviews some of the experimental works done by researchers on this technique in recent years. The variously modified twisted tape inserts are widely researched and used to enhance heat transfer efficiency for heat exchangers. Twisted tapes perform better in low Re conditions and in square tubes. However, they could also cause higher pressure drops. Twisted tapes have great potential and profound implications if they can be used in traditional heat exchangers. Besides this, some correlations between the Nusselt number and friction factors are presented in this paper.展开更多
This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive ...This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive and capacitive parasitic components in the converter. The switch devices operate in a zero-voltage soft-switching mode. Consequently, the high voltage and high current spikes caused by parasitic inductors or capacitors oscillation do not occur in this circuit, and the high power loss caused by high frequency switching can be greatly reduced. A large value inductor is adopted between the input capacitor and the switches, thus, this novel converter shares the benefits of both voltage-type and current-type circuits simultaneously, and there are no needs of dead time between two switches. The working principles in different modes are introduced. Results of simulation and experiments operated at around 1 MHz frequency verify the validity of parasitic components absorption and show that this convener is competent for super high frequency applications.展开更多
To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and pre...To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economi- cal and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than ¥5 and when one flushing pump ahemately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.展开更多
Flow characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Stream...Flow characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Streamline and velocity contour graphs at different cross-sections were obtained in the experiment. The experimental results indicate that flow maldistribution in the conventional header is very serious, while the improved header configuration with punched baffle can effectively improve the uniformity. The flow maldistribution parameter in plate-fin heat exchanger has been reduced from 1.21 to 0.21, and the ratio of the maximum velocity to the minimum is reduced from 23.2 to 1.8 by install-ing the punched baffle. The results suggest room for the optimum design of plate-fin heat exchanger.展开更多
A new superstructure model of heat exchanger networks (HEN) with streamsplits based on rangers of streams supply temperatures and heat capacity flow rates is presented.The simultaneous optimal mathematical model of fl...A new superstructure model of heat exchanger networks (HEN) with streamsplits based on rangers of streams supply temperatures and heat capacity flow rates is presented.The simultaneous optimal mathematical model of flexible HEN synthesis is established too. Firstly,the streams with rangers of supply temperatures and/or the streams with the rangers of heat capacityflow rates are pretreated; Secondly, several rules are proposed to establish the superstructuremodel of HEN with splits and the simultaneous optimal mathematical model of flexible HEN; Thirdly,the improving genetic algorithm is applied to solve the mathematical model established at the secondstep effectively, and the original optimal structure of HEN based on the maximum operation limitingcondition can be obtained easily; Finally, the rules of heat exchange unit merged and the heat loadof heat exchanger relaxed are presented, the flexible configuration of HEN satisfied the operationcondition between the upper and down bounds of supply temperature and heat capacity flow rates canbe obtained based on the original optimal structure of HEN by means of these rules. A case studydemonstrates the method presented in this paper is effective展开更多
As the operation time of heat exchanger is increased, the thermal performance of them is gradually degraded due to fouling generated by water-borne deposits which are known to reduce the thermal efficiencies. Currentl...As the operation time of heat exchanger is increased, the thermal performance of them is gradually degraded due to fouling generated by water-borne deposits which are known to reduce the thermal efficiencies. Currently, thermal performance management of heat exchangers is more importantly issued for long term operation. Therefore, the performance evaluation techniques are required to improve the present method for the integrity evaluation of heat exchangers because of the exclusion of fouling calculation and the uncertainty analysis. This paper describes the developed thermal performance evaluation technique applied to the safety-related heat exchangers such as component cooling heat exchangers in a nuclear power plants.展开更多
The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out ...The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out by theoretical method. The results show that the pinch point position depends on the parameters of the heat transfer fluids and the major fluid properties. In most cases, the pinch point locates at the bubble point for the evaporator and the dew point for the condenser. However, the pinch point shills to the supercooled liquid state in the near critical conditions for the evaporator. Similarly, it shifts to the superheated vapor state with the condensing temperature approaching the critical temperature for the condenser. It even can shift to the working fluid entrance of the evaporator or the supereritical heater when the heat source fluid temperature is very high compared with the absorb- ing heat temperature. A wrong position for the pinch point may generate serious mistake. In brief, the pinch point should be founded by the itcrativc method in all conditions rather than taking for granted.展开更多
文摘Heat transfer enhancement is used in many applications including heat exchangers, air conditioning, and refrigeration systems; hence many researchers have conducted experimental and numerical researches on heat transfer enhancement and have developed various techniques and methods. As a passive heat transfer technique, twisted tapes are widely used in various industries for their cost savings, lower maintenance requirements and the fact that they are easily set up. This paper introduces the principle of heat transfer enhancement of twisted tapes and reviews some of the experimental works done by researchers on this technique in recent years. The variously modified twisted tape inserts are widely researched and used to enhance heat transfer efficiency for heat exchangers. Twisted tapes perform better in low Re conditions and in square tubes. However, they could also cause higher pressure drops. Twisted tapes have great potential and profound implications if they can be used in traditional heat exchangers. Besides this, some correlations between the Nusselt number and friction factors are presented in this paper.
文摘This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive and capacitive parasitic components in the converter. The switch devices operate in a zero-voltage soft-switching mode. Consequently, the high voltage and high current spikes caused by parasitic inductors or capacitors oscillation do not occur in this circuit, and the high power loss caused by high frequency switching can be greatly reduced. A large value inductor is adopted between the input capacitor and the switches, thus, this novel converter shares the benefits of both voltage-type and current-type circuits simultaneously, and there are no needs of dead time between two switches. The working principles in different modes are introduced. Results of simulation and experiments operated at around 1 MHz frequency verify the validity of parasitic components absorption and show that this convener is competent for super high frequency applications.
基金Sponsored by the National Natural Science Foundation of China (Grant No.50578048)
文摘To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economi- cal and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than ¥5 and when one flushing pump ahemately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.
基金Supported by the Foundation for Excellent Doctoral Dissertation Author by Ministry of Education of China (No.199933).
文摘Flow characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Streamline and velocity contour graphs at different cross-sections were obtained in the experiment. The experimental results indicate that flow maldistribution in the conventional header is very serious, while the improved header configuration with punched baffle can effectively improve the uniformity. The flow maldistribution parameter in plate-fin heat exchanger has been reduced from 1.21 to 0.21, and the ratio of the maximum velocity to the minimum is reduced from 23.2 to 1.8 by install-ing the punched baffle. The results suggest room for the optimum design of plate-fin heat exchanger.
基金Supported by the State Major Basic Research Department Program of China (No. G20000263) and the Deutsche Forschungs- gemeinschaft(DFG)(No. RO294/9).
文摘A new superstructure model of heat exchanger networks (HEN) with streamsplits based on rangers of streams supply temperatures and heat capacity flow rates is presented.The simultaneous optimal mathematical model of flexible HEN synthesis is established too. Firstly,the streams with rangers of supply temperatures and/or the streams with the rangers of heat capacityflow rates are pretreated; Secondly, several rules are proposed to establish the superstructuremodel of HEN with splits and the simultaneous optimal mathematical model of flexible HEN; Thirdly,the improving genetic algorithm is applied to solve the mathematical model established at the secondstep effectively, and the original optimal structure of HEN based on the maximum operation limitingcondition can be obtained easily; Finally, the rules of heat exchange unit merged and the heat loadof heat exchanger relaxed are presented, the flexible configuration of HEN satisfied the operationcondition between the upper and down bounds of supply temperature and heat capacity flow rates canbe obtained based on the original optimal structure of HEN by means of these rules. A case studydemonstrates the method presented in this paper is effective
文摘As the operation time of heat exchanger is increased, the thermal performance of them is gradually degraded due to fouling generated by water-borne deposits which are known to reduce the thermal efficiencies. Currently, thermal performance management of heat exchangers is more importantly issued for long term operation. Therefore, the performance evaluation techniques are required to improve the present method for the integrity evaluation of heat exchangers because of the exclusion of fouling calculation and the uncertainty analysis. This paper describes the developed thermal performance evaluation technique applied to the safety-related heat exchangers such as component cooling heat exchangers in a nuclear power plants.
基金Project 51306198 supported by National Natural Science Foundation of China is gratefully acknowledged
文摘The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out by theoretical method. The results show that the pinch point position depends on the parameters of the heat transfer fluids and the major fluid properties. In most cases, the pinch point locates at the bubble point for the evaporator and the dew point for the condenser. However, the pinch point shills to the supercooled liquid state in the near critical conditions for the evaporator. Similarly, it shifts to the superheated vapor state with the condensing temperature approaching the critical temperature for the condenser. It even can shift to the working fluid entrance of the evaporator or the supereritical heater when the heat source fluid temperature is very high compared with the absorb- ing heat temperature. A wrong position for the pinch point may generate serious mistake. In brief, the pinch point should be founded by the itcrativc method in all conditions rather than taking for granted.