The localized micro-galvanic corrosion process and the kinetic information of Mg-(7,9)Al-1Fe-x Nd alloys were investigated by in situ observation under electrochemical control and in situ atomic force microscopy(AFM)i...The localized micro-galvanic corrosion process and the kinetic information of Mg-(7,9)Al-1Fe-x Nd alloys were investigated by in situ observation under electrochemical control and in situ atomic force microscopy(AFM)in an electrolyte environment.The results revealed that the formation of the Nd-rich phase in alloys resulted in a decrease in the Volta potential difference from~400 m V(AlFe3/α-Mg)to~220 mV(Nd-rich/α-Mg),reducing the corrosion products around the cathodic phase and corrosion current density of the microscale area.The addition of Nd significantly improved the corrosion resistance,mainly due to the suppression of the micro-galvanic corrosion between the second phases and substrate.Finally,the corrosion mechanism of Mg-(7,9)Al-1Fe-x Nd alloys was discussed based on in situ observations and electrochemical results.展开更多
The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/...The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/L NaC1 + 0.01 mol/L Na2S203 solution under slow-strain-rate-testing (SSRT) conditions. Moreover, the characteristics of L-crack's surface morphology and potential distribution with scanning Kelvin probe (SKP) before and after SSRT were also discussed. Compared with S-crack, L-crack is propagated and the features of crack propagation can be obtained. After propagation, the noise amplitudes increase with increasing stress and accelerating corrosion, the white noises at low and high frequencies (WE and WH) of the later stage are one order of magnitude larger than that at early stage in the current power spectral densities (PSDs). The potential PSDs also increase, but WH disappears. In addition, the crack propagation can be demonstrated according to variation of probability distribution, surface morphology and potential distribution.展开更多
The degradation coefficient is proposed to evaluate the degradation degree of organic coatings by directly anaIyzing the Bode plots of the electrochemical impedance spectroscopy (EIS) data. This paper investigated t...The degradation coefficient is proposed to evaluate the degradation degree of organic coatings by directly anaIyzing the Bode plots of the electrochemical impedance spectroscopy (EIS) data. This paper investigated the degradation of phenolic epoxy coating/tinplate system by EIS and the degradation coefficient value, which correlates well with the results of breakpoint frequency and variation of phase angle at 10 Hz. Furthermore, the degradation process was confirmed by scanning electron microscope (SEM) and scanning probe microscopy (SPM). It is concluded that degradation coefficient can be used for the fast evaluation of degradation degree of organic coatings in practical appli- cations.展开更多
AIM: To identify multi-detector computed tomography (MDCT) features most predictive of serous cystadenomas (SCAs), correlating with histopathology, and to study the impact of cyst size and MDCT technique on reade...AIM: To identify multi-detector computed tomography (MDCT) features most predictive of serous cystadenomas (SCAs), correlating with histopathology, and to study the impact of cyst size and MDCT technique on reader performance. METHODS: The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs. Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or 〉≥3 cm) and scanning protocols (dedicated vs routine). RESULTS: 28/164 cysts (mean size, 39 mm; range, 8-92 mm) were diagnosed as SCA on pathology. The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28, 78.6%), surface Iobulations (25/28, 89.3%) and central scar (9/28, 32.4%). Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P = 0.0001). The sensitivity, specificity and PPV of central scar and of combined microcystic appearance and Iobulations were 32.4%/100%/100% and 68%/100%/100%, respectively. The reader confidence was higher for lesions 〉 3 cm (P = 0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P 〉 0.05). CONCLUSION: Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs. Microcystic morphology is the most significant CT feature in diagnosis of SCA. A combination of microcystic appearance and surface Iobulations offers accuracy comparable to central scar with higher sensitivity.展开更多
AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT) scanning for detection of small hepatocellular carcinoma (HCC). METHODS: M...AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT) scanning for detection of small hepatocellular carcinoma (HCC). METHODS: MDCT scanning and baseline MRI with SE T1-WI and T2-WI sequence combined with FMPSPGR sequence were performed in 37 patients with 43 small HCCs. Receiver operating characteristic (ROC) curves were plotted to analyze the results for modality. RESULTS: The areas below ROC curve (Az) were calculated. There was no statistical difference in dynamic enhancement MDCT and MRI. The detection rate of small HCC was 97.5%-97.6% on multiphase MDCT scanning and 90.7%-94.7% on MRI, respectively. The sensitivity of detection for small HCC on MDCT scanning was higher than that on dynamic enhancement MRI. The sensitivity of detection for minute HCC (tumor diameter ≤ 1 cm) was 90.0%-95.0% on MDCT scanning and 70.0%-85.0% on MRI, respectively. CONCLUSION: MDCT scanning should be performed for early detection and effective treatment of small HCC in patients with chronic hepatitis and cirrhosis during follow-up.展开更多
A combination of NAA and micro-PIXE was used to study concentrations and distributions of platinum group elements (PGE) in ores from Xinjie Cu-Pt deposit.The NAA results of the bulk indicate that the ores belong to th...A combination of NAA and micro-PIXE was used to study concentrations and distributions of platinum group elements (PGE) in ores from Xinjie Cu-Pt deposit.The NAA results of the bulk indicate that the ores belong to the enriched Pt-Pd type.The element concentration maps of scanning micro-PIXE for the ores show that the occurence form of Pt is independent arsenide minerals. No PGE were detected in chalcopyrite of Xinjie Cu-Pt deposit. These information are economically beneficial to the mineral smelting process.展开更多
Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. Th...Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. The conventional cavity detection methods and their limitation were analyzed. Those methods cannot form 3D model of underground cavity which is used for instructing the cavity disposal; and their precisions in detection are always greatly affected by the geological circumstance. The importance of 3D cavity detection in metal mine for safe exploitation was pointed out; and the 3D cavity laser detection method and its principle were introduced. A cavity auto scanning laser system was recommended to actualize the cavity 3D detection after comparing with the other laser detection systems. Four boreholes were chosen to verify the validity of the cavity auto scanning laser system. The results show that the cavity auto scanning laser system is very suitable for underground 3D cavity detection, especially for those inaccessible ones.展开更多
The corrosion behavior of tinplate cans containing coffee was investigated using novel electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) sensors.The contents of iron and tin dissolved in cans w...The corrosion behavior of tinplate cans containing coffee was investigated using novel electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) sensors.The contents of iron and tin dissolved in cans were detected by inductively coupled plasma mass spectrometer(ICP-MS),and the morphology of corroded surface was observed by optical microscopy and scanning probe microscopy(SPM).The results reveal that the coating resistance,charge transfer resistance and noise resistance decrease with the prolongation of storage time.The iron and tin contents in cans increase with the storage time,while the bump height of coating surface increases from 30 nm to 80 nm during the corrosion of twelve months.The existence of deformation would enhance the corrosion process of tinplate cans.Finally,the corrosion mechanism of tinplate cans in coffee was proposed.展开更多
基金financial support from the National Natural Science Foundation of China(No.51961026)。
文摘The localized micro-galvanic corrosion process and the kinetic information of Mg-(7,9)Al-1Fe-x Nd alloys were investigated by in situ observation under electrochemical control and in situ atomic force microscopy(AFM)in an electrolyte environment.The results revealed that the formation of the Nd-rich phase in alloys resulted in a decrease in the Volta potential difference from~400 m V(AlFe3/α-Mg)to~220 mV(Nd-rich/α-Mg),reducing the corrosion products around the cathodic phase and corrosion current density of the microscale area.The addition of Nd significantly improved the corrosion resistance,mainly due to the suppression of the micro-galvanic corrosion between the second phases and substrate.Finally,the corrosion mechanism of Mg-(7,9)Al-1Fe-x Nd alloys was discussed based on in situ observations and electrochemical results.
基金Project(2006CB605004) supported by the National Basic Research Program of China
文摘The fatigue pre-cracking 304 stainless steel (SS) specimens with lengths of 1.002 mm (L-crack) and 0.575 mm (S-crack) were prepared. Their corrosion behavior was studied by electrochemical noise (EN) in 4 mol/L NaC1 + 0.01 mol/L Na2S203 solution under slow-strain-rate-testing (SSRT) conditions. Moreover, the characteristics of L-crack's surface morphology and potential distribution with scanning Kelvin probe (SKP) before and after SSRT were also discussed. Compared with S-crack, L-crack is propagated and the features of crack propagation can be obtained. After propagation, the noise amplitudes increase with increasing stress and accelerating corrosion, the white noises at low and high frequencies (WE and WH) of the later stage are one order of magnitude larger than that at early stage in the current power spectral densities (PSDs). The potential PSDs also increase, but WH disappears. In addition, the crack propagation can be demonstrated according to variation of probability distribution, surface morphology and potential distribution.
基金Supported by Major State Basic Research Program of China ("973"Program,No. 2011CB610500)
文摘The degradation coefficient is proposed to evaluate the degradation degree of organic coatings by directly anaIyzing the Bode plots of the electrochemical impedance spectroscopy (EIS) data. This paper investigated the degradation of phenolic epoxy coating/tinplate system by EIS and the degradation coefficient value, which correlates well with the results of breakpoint frequency and variation of phase angle at 10 Hz. Furthermore, the degradation process was confirmed by scanning electron microscope (SEM) and scanning probe microscopy (SPM). It is concluded that degradation coefficient can be used for the fast evaluation of degradation degree of organic coatings in practical appli- cations.
文摘AIM: To identify multi-detector computed tomography (MDCT) features most predictive of serous cystadenomas (SCAs), correlating with histopathology, and to study the impact of cyst size and MDCT technique on reader performance. METHODS: The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs. Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or 〉≥3 cm) and scanning protocols (dedicated vs routine). RESULTS: 28/164 cysts (mean size, 39 mm; range, 8-92 mm) were diagnosed as SCA on pathology. The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28, 78.6%), surface Iobulations (25/28, 89.3%) and central scar (9/28, 32.4%). Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P = 0.0001). The sensitivity, specificity and PPV of central scar and of combined microcystic appearance and Iobulations were 32.4%/100%/100% and 68%/100%/100%, respectively. The reader confidence was higher for lesions 〉 3 cm (P = 0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P 〉 0.05). CONCLUSION: Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs. Microcystic morphology is the most significant CT feature in diagnosis of SCA. A combination of microcystic appearance and surface Iobulations offers accuracy comparable to central scar with higher sensitivity.
基金a financial assistance from Zhuhai Technology Bureau, No. PC20052025
文摘AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT) scanning for detection of small hepatocellular carcinoma (HCC). METHODS: MDCT scanning and baseline MRI with SE T1-WI and T2-WI sequence combined with FMPSPGR sequence were performed in 37 patients with 43 small HCCs. Receiver operating characteristic (ROC) curves were plotted to analyze the results for modality. RESULTS: The areas below ROC curve (Az) were calculated. There was no statistical difference in dynamic enhancement MDCT and MRI. The detection rate of small HCC was 97.5%-97.6% on multiphase MDCT scanning and 90.7%-94.7% on MRI, respectively. The sensitivity of detection for small HCC on MDCT scanning was higher than that on dynamic enhancement MRI. The sensitivity of detection for minute HCC (tumor diameter ≤ 1 cm) was 90.0%-95.0% on MDCT scanning and 70.0%-85.0% on MRI, respectively. CONCLUSION: MDCT scanning should be performed for early detection and effective treatment of small HCC in patients with chronic hepatitis and cirrhosis during follow-up.
文摘A combination of NAA and micro-PIXE was used to study concentrations and distributions of platinum group elements (PGE) in ores from Xinjie Cu-Pt deposit.The NAA results of the bulk indicate that the ores belong to the enriched Pt-Pd type.The element concentration maps of scanning micro-PIXE for the ores show that the occurence form of Pt is independent arsenide minerals. No PGE were detected in chalcopyrite of Xinjie Cu-Pt deposit. These information are economically beneficial to the mineral smelting process.
基金Project(50490274) supported by the National Natural Science Foundation of China
文摘Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. The conventional cavity detection methods and their limitation were analyzed. Those methods cannot form 3D model of underground cavity which is used for instructing the cavity disposal; and their precisions in detection are always greatly affected by the geological circumstance. The importance of 3D cavity detection in metal mine for safe exploitation was pointed out; and the 3D cavity laser detection method and its principle were introduced. A cavity auto scanning laser system was recommended to actualize the cavity 3D detection after comparing with the other laser detection systems. Four boreholes were chosen to verify the validity of the cavity auto scanning laser system. The results show that the cavity auto scanning laser system is very suitable for underground 3D cavity detection, especially for those inaccessible ones.
基金Project(2011CB610500)supported by the National Key Basic Research Program of ChinaProject(13JCZDJC29500)supported by the Natural Science Foundation of Tianjin Municipality,ChinaProject(20130032110029)supported by the Specialized Research Fund for the Doctoral Program of Higher Education,China
文摘The corrosion behavior of tinplate cans containing coffee was investigated using novel electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) sensors.The contents of iron and tin dissolved in cans were detected by inductively coupled plasma mass spectrometer(ICP-MS),and the morphology of corroded surface was observed by optical microscopy and scanning probe microscopy(SPM).The results reveal that the coating resistance,charge transfer resistance and noise resistance decrease with the prolongation of storage time.The iron and tin contents in cans increase with the storage time,while the bump height of coating surface increases from 30 nm to 80 nm during the corrosion of twelve months.The existence of deformation would enhance the corrosion process of tinplate cans.Finally,the corrosion mechanism of tinplate cans in coffee was proposed.