TN929.1 99021254激光对潜通信的信号检测方法分析=Analysis onthe signal detection methods of SLC[刊,中]/杜竹峰,黄铁侠,卢益民(华中理工大学.湖北,武汉(430074))∥激光与红外.—1998,28(3).—156-159对激光对潜通信系统的信号检测...TN929.1 99021254激光对潜通信的信号检测方法分析=Analysis onthe signal detection methods of SLC[刊,中]/杜竹峰,黄铁侠,卢益民(华中理工大学.湖北,武汉(430074))∥激光与红外.—1998,28(3).—156-159对激光对潜通信系统的信号检测方法作了较详细的分析与比较。根据激光对潜通信系统的信道特性和探测器特性,推导并简化了输出信噪比公式,研究了信噪比对检测系统性能的影响。图2表1参8(李瑞琴)展开更多
The response of a silicon alpha detector to beta particles, electrons and photons was investigated using measurements and Monte Carlo simulations. This information is of relevance for in situ alpha spectrometry from d...The response of a silicon alpha detector to beta particles, electrons and photons was investigated using measurements and Monte Carlo simulations. This information is of relevance for in situ alpha spectrometry from different surfaces at ambient air pressure. According to the simulations, photon detection efficiencies were more than two orders of magnitude smaller than those of electrons. Photons generate signals mainly by Compton electrons. Counts originating from beta particles, electrons and photons were usually below 1 MeV in energy and no clear peaks could be identified from the measured spectra. Unequivocal identification of radionuclides emitting beta particles, electrons and photons is not possible when a mixture of different radionuclides is present in the source. However, radionuclide classification according to their emission energies appears to be possible. Surface contamination measurements will benefit from this capability.展开更多
Based on Lucovsky equation,the response solution of 1-D position sensitive detector(PSD) is given under the condition of parallel light oblique incidence and Gaussian beam oblique incidence,and the response characteri...Based on Lucovsky equation,the response solution of 1-D position sensitive detector(PSD) is given under the condition of parallel light oblique incidence and Gaussian beam oblique incidence,and the response characteristics are analyzed by numerical calculation. The relation between oblique incident angle and output current is introduced and illustrated.展开更多
The edge plasma characteristics are studied by a movable array of Mach/Reynolds stress/Langmuir 10-probes and fast reciprocating 4-probes in the boundary region. These probes can measure edge plasma temperature, densi...The edge plasma characteristics are studied by a movable array of Mach/Reynolds stress/Langmuir 10-probes and fast reciprocating 4-probes in the boundary region. These probes can measure edge plasma temperature, density, poloidal electric field, radial electric field, Reynolds stress, poloidal rotation velocities and their profiles obtained by changing the radial positions of the probe array in different discharges. Measurement resuits are used to analyze plasma confinement, turbulent fluctuations and their correlation. The fixed flush 3-probe arrays are mounted on the 4-divertor neutralization plates at the same toroidal cross-section in divertor chamber. These probes are used to measure the profiles of the electron temperature, density and float potential in divertor chamber.展开更多
文摘TN929.1 99021254激光对潜通信的信号检测方法分析=Analysis onthe signal detection methods of SLC[刊,中]/杜竹峰,黄铁侠,卢益民(华中理工大学.湖北,武汉(430074))∥激光与红外.—1998,28(3).—156-159对激光对潜通信系统的信号检测方法作了较详细的分析与比较。根据激光对潜通信系统的信道特性和探测器特性,推导并简化了输出信噪比公式,研究了信噪比对检测系统性能的影响。图2表1参8(李瑞琴)
文摘The response of a silicon alpha detector to beta particles, electrons and photons was investigated using measurements and Monte Carlo simulations. This information is of relevance for in situ alpha spectrometry from different surfaces at ambient air pressure. According to the simulations, photon detection efficiencies were more than two orders of magnitude smaller than those of electrons. Photons generate signals mainly by Compton electrons. Counts originating from beta particles, electrons and photons were usually below 1 MeV in energy and no clear peaks could be identified from the measured spectra. Unequivocal identification of radionuclides emitting beta particles, electrons and photons is not possible when a mixture of different radionuclides is present in the source. However, radionuclide classification according to their emission energies appears to be possible. Surface contamination measurements will benefit from this capability.
基金Program of the Science and Technology Department of Fujian Province(2007F5040)
文摘Based on Lucovsky equation,the response solution of 1-D position sensitive detector(PSD) is given under the condition of parallel light oblique incidence and Gaussian beam oblique incidence,and the response characteristics are analyzed by numerical calculation. The relation between oblique incident angle and output current is introduced and illustrated.
文摘The edge plasma characteristics are studied by a movable array of Mach/Reynolds stress/Langmuir 10-probes and fast reciprocating 4-probes in the boundary region. These probes can measure edge plasma temperature, density, poloidal electric field, radial electric field, Reynolds stress, poloidal rotation velocities and their profiles obtained by changing the radial positions of the probe array in different discharges. Measurement resuits are used to analyze plasma confinement, turbulent fluctuations and their correlation. The fixed flush 3-probe arrays are mounted on the 4-divertor neutralization plates at the same toroidal cross-section in divertor chamber. These probes are used to measure the profiles of the electron temperature, density and float potential in divertor chamber.