The effective detection depth of the needle-like optical probe is studied. The light transport model in highly scattering tissue is the diffusion equation and the boundary is Neuman. The sensitivity matrix is related ...The effective detection depth of the needle-like optical probe is studied. The light transport model in highly scattering tissue is the diffusion equation and the boundary is Neuman. The sensitivity matrix is related to the position of the light source and the detector. It can be used to evaluate the effective detection depth. The sensitivity matrix is defined as the multiplication of the source and detector hght distribution. Six different groups about ix parameters including the source diameter and detector fibers, the core-to-core distance between the source and detector fibers, the opotode depth, the absorption, and reduced scattering coefficient, are used as experimental models. The relationship between the six parameters and the effective detection depth is analyzed. Resuits can be used to study the spatial resolution and the depth of multi-fibers.展开更多
Thoron (Rn-220) is an invisible, odorless radioactive gas and nine times heavier than air. Purpose of project is to set up procedure to determine Rn-220 concentration which has been carried out in laboratory using S...Thoron (Rn-220) is an invisible, odorless radioactive gas and nine times heavier than air. Purpose of project is to set up procedure to determine Rn-220 concentration which has been carried out in laboratory using Solid State Nuclear Track Detector (SSNTD) based passive detector technique. In this study, technical procedure has been applied in Karlsruhe diffusion chamber and LR-115, Type II strippable (Kodak Pathe, France) detector. The results have investigated how LR-115 work for Rn-220 by using Monazite ore to simultaneously measure Rn-222 and Rn-220. To carry out experiment, Karlsruhe diffusion chamber is used to with and without Poly-Ethylene (PE) membrane. Karlsruhe diffusion chamber with PE membrane only detect Rn-222, without PE membrane detect total Rn-222 and Rn-220. Precision evaluation by duplicate measure at 8 cm detector-source distance with relative standard deviation is less than 2.54%. Testing technical procedure, detectors have been sent to National Institute of Radiological Science (NIRS) for Rn-220 calibration exposure. After detectors have been calibration exposure at NIRS, it carried out all the following steps of procedure which set up at laboratory in 1NST, Vietnam. Finally, calibration factor calculated is 0.21 (tracks-cm2/Bq·m3·h) and constructed curve between integrated Tn-220 concentration and tracks density with factor R2 = 0.975.展开更多
基金Supported by the Natural Science Foundation of Jiangsu Province (BK2009371)the National High Technology Research and Development Program of China ("863" Program) (2008AA02Z438)~~
文摘The effective detection depth of the needle-like optical probe is studied. The light transport model in highly scattering tissue is the diffusion equation and the boundary is Neuman. The sensitivity matrix is related to the position of the light source and the detector. It can be used to evaluate the effective detection depth. The sensitivity matrix is defined as the multiplication of the source and detector hght distribution. Six different groups about ix parameters including the source diameter and detector fibers, the core-to-core distance between the source and detector fibers, the opotode depth, the absorption, and reduced scattering coefficient, are used as experimental models. The relationship between the six parameters and the effective detection depth is analyzed. Resuits can be used to study the spatial resolution and the depth of multi-fibers.
文摘Thoron (Rn-220) is an invisible, odorless radioactive gas and nine times heavier than air. Purpose of project is to set up procedure to determine Rn-220 concentration which has been carried out in laboratory using Solid State Nuclear Track Detector (SSNTD) based passive detector technique. In this study, technical procedure has been applied in Karlsruhe diffusion chamber and LR-115, Type II strippable (Kodak Pathe, France) detector. The results have investigated how LR-115 work for Rn-220 by using Monazite ore to simultaneously measure Rn-222 and Rn-220. To carry out experiment, Karlsruhe diffusion chamber is used to with and without Poly-Ethylene (PE) membrane. Karlsruhe diffusion chamber with PE membrane only detect Rn-222, without PE membrane detect total Rn-222 and Rn-220. Precision evaluation by duplicate measure at 8 cm detector-source distance with relative standard deviation is less than 2.54%. Testing technical procedure, detectors have been sent to National Institute of Radiological Science (NIRS) for Rn-220 calibration exposure. After detectors have been calibration exposure at NIRS, it carried out all the following steps of procedure which set up at laboratory in 1NST, Vietnam. Finally, calibration factor calculated is 0.21 (tracks-cm2/Bq·m3·h) and constructed curve between integrated Tn-220 concentration and tracks density with factor R2 = 0.975.