期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
含四桥臂H桥变流器的不对称配电网综合补偿方法 被引量:8
1
作者 游建章 郭谋发 《电工技术学报》 EI CSCD 北大核心 2022年第11期2849-2858,共10页
为解决配电网电力电子设备存在的功能单一、利用率低、造价高及协同难等问题,提出含四桥臂H桥变流器的不对称配电网综合补偿方法。在静止无功发生器的中性点增设级联H桥对地支路的新型综合补偿装置结构,为接地故障和三相对地参数不对称... 为解决配电网电力电子设备存在的功能单一、利用率低、造价高及协同难等问题,提出含四桥臂H桥变流器的不对称配电网综合补偿方法。在静止无功发生器的中性点增设级联H桥对地支路的新型综合补偿装置结构,为接地故障和三相对地参数不对称的补偿电流提供流通回路,考虑配电网三相对地参数不对称和三相负荷不平衡的影响,将有功和无功功率补偿、三相不平衡负荷补偿和三相对地参数不对称电流以及接地故障电流补偿等功能集成至同一套补偿装置。在分析各功能的原理及相互作用机理的基础上,提出基于分序解耦控制的多目标协同控制策略,以及三相对地参数不对称电流补偿与接地故障电流补偿的切换方法。正常运行时,综合补偿装置动态补偿配电网有功功率和无功功率、三相不平衡负荷及三相对地参数不对称电流;接地故障时,三相对地参数不对称电流补偿切换至接地故障电流补偿。仿真结果验证了所提方法的有效性。 展开更多
关键词 不对称配电网 综合补偿 功率补偿 不对称补偿 接地故障补偿 四桥臂H桥变流器
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
2
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation Grounding current detection Zero sequence voltage detection
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部