The status and supporting policies of cold chain logistics equipment man- agement and control in China were described. The connotation of Internet of Things and its impact on cold chain logistics equipment management ...The status and supporting policies of cold chain logistics equipment man- agement and control in China were described. The connotation of Internet of Things and its impact on cold chain logistics equipment management and control were ana- lyzed from external form to internal nature. Through introducing the value chain and relevant equipments of cold chain logistics, the correlation between the main technologies in Internet of Things and the common indices for cold chain logistics equipment management and control was analyzed in detail. The application values of Internet of Things technologies in cold chain logistics equipment management and control were illustrated, including the sample analysis on the application of radio-frequency identification (RFID). After the establishment of BSC performance evaluation index system of cold chain logistics equipment management and control, the optimization measures and suggestions on cold chain logistics equipment management and control under Internet of Things were put forward.展开更多
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ...The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant.展开更多
基金Supported by the Project of Philosophy and Social Sciences during the 12th Five-year Plan of Guangxi Zhuang Autonomous Region,China (11FGL031)~~
文摘The status and supporting policies of cold chain logistics equipment man- agement and control in China were described. The connotation of Internet of Things and its impact on cold chain logistics equipment management and control were ana- lyzed from external form to internal nature. Through introducing the value chain and relevant equipments of cold chain logistics, the correlation between the main technologies in Internet of Things and the common indices for cold chain logistics equipment management and control was analyzed in detail. The application values of Internet of Things technologies in cold chain logistics equipment management and control were illustrated, including the sample analysis on the application of radio-frequency identification (RFID). After the establishment of BSC performance evaluation index system of cold chain logistics equipment management and control, the optimization measures and suggestions on cold chain logistics equipment management and control under Internet of Things were put forward.
基金Project(G-0805-10156) supported by US Energy Foundation
文摘The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant.