The aim of the present study was to implant an efficient strategy for controlling the level of the effluent-oily foam interface in a DAF (dissolved air flotation) chamber of a pilot-scale prototype. DAF has been suc...The aim of the present study was to implant an efficient strategy for controlling the level of the effluent-oily foam interface in a DAF (dissolved air flotation) chamber of a pilot-scale prototype. DAF has been successfully used in the treatment of oily water, which is one of the main environmental problems in different industrial facilities. Along with important operational parameters, such as microbubble size and flow rate, the control strategy for the automation of a DAF chamber may be an important tool for increasing efficiency. Controlling the level was the strategy chosen to enhance the separation efficiency in a pilot-scale DAF prototype, with monitoring performed using a computational program in LabVIEW (laboratory virtual instrument engineering workbench). The findings demonstrate that it is possible to maintain the level of the fluid at a reference value established by the operator using the software program through the application of classic proportional integral derivative controllers. Using this control tool, the efficiency of water-oil separation in the pilot flotation chamber prototype was increased to nearly 98%.展开更多
According to the new structure of the jet flotation column, a system which can measure and control the parameters of the column flotation system is successfully designed.
In this work,the dynamics and operation of the totally reboiled reactive distillation columns are visualized in terms of transfer function based process models.This kind of processes is found to be characterized by un...In this work,the dynamics and operation of the totally reboiled reactive distillation columns are visualized in terms of transfer function based process models.This kind of processes is found to be characterized by underdamped step responses due to the special topological configuration and the intricate interplay between the reaction operation and the separation operation involved.The under-dampness can be substantially alleviated through the tight inventory control of bottom reboiler and this presents beneficial effects to process dynamics and operation.Two totally reboiled reactive distillation columns,separating,respectively,a hypothetical synthesis reaction from reactants A and B to product C,and a real decomposition reaction from 1,4-butanediol to tetrahydrofuran and water,are employed to demonstrate these uncommon behaviors.The results obtained give full support to the above qualitative interpretation.Despite the strong influences of reaction kinetics and thermodynamic properties of the reacting mixtures,the totally reboiled reactive distillation columns are generally considered to present such unique behaviors and require tight inventory control of bottom reboiler to facilitate their control system development.展开更多
To make magnetic separator more excellent in beneficiation, an advanced automatic control system for magnetic separator was designed. This paper designs automatic control system for magnetic separators, combination wi...To make magnetic separator more excellent in beneficiation, an advanced automatic control system for magnetic separator was designed. This paper designs automatic control system for magnetic separators, combination with PLC and technology of vary frequency. This system can wholly supervise and control the parameters of work course of magnetic separators.展开更多
Flow separation in a conical diffuser with large divergence angle (29.14°) and large area ratio (3.533) is eliminated by a novel passive flow control device called Karman-Vortex Generator (KVG). The effect ...Flow separation in a conical diffuser with large divergence angle (29.14°) and large area ratio (3.533) is eliminated by a novel passive flow control device called Karman-Vortex Generator (KVG). The effect of the KVG is verified and investigated by the URANS, DES and DDES methods based on the SST model. CFD results show that the performance coefficient of the diffuser can be doubled by the KVG, and the total pressure recovery coefficient can be improved by about 1.2%. DES and DDES re- suits show that the KVG can introduce a Karman-vortex street frequency in the diffuser. This frequency decays rapidly, and could not be detected in the ending plane of the expansion section, Different KVG configurations with different locations and dimensions are numerically simulated and compared. Some suggestions are provided.展开更多
文摘The aim of the present study was to implant an efficient strategy for controlling the level of the effluent-oily foam interface in a DAF (dissolved air flotation) chamber of a pilot-scale prototype. DAF has been successfully used in the treatment of oily water, which is one of the main environmental problems in different industrial facilities. Along with important operational parameters, such as microbubble size and flow rate, the control strategy for the automation of a DAF chamber may be an important tool for increasing efficiency. Controlling the level was the strategy chosen to enhance the separation efficiency in a pilot-scale DAF prototype, with monitoring performed using a computational program in LabVIEW (laboratory virtual instrument engineering workbench). The findings demonstrate that it is possible to maintain the level of the fluid at a reference value established by the operator using the software program through the application of classic proportional integral derivative controllers. Using this control tool, the efficiency of water-oil separation in the pilot flotation chamber prototype was increased to nearly 98%.
文摘According to the new structure of the jet flotation column, a system which can measure and control the parameters of the column flotation system is successfully designed.
基金Supported by The National Natural Science Foundation of China(21076015,21376018,and 21576014)The Fundamental Research Funds for the Central Universities(ZY1503)
文摘In this work,the dynamics and operation of the totally reboiled reactive distillation columns are visualized in terms of transfer function based process models.This kind of processes is found to be characterized by underdamped step responses due to the special topological configuration and the intricate interplay between the reaction operation and the separation operation involved.The under-dampness can be substantially alleviated through the tight inventory control of bottom reboiler and this presents beneficial effects to process dynamics and operation.Two totally reboiled reactive distillation columns,separating,respectively,a hypothetical synthesis reaction from reactants A and B to product C,and a real decomposition reaction from 1,4-butanediol to tetrahydrofuran and water,are employed to demonstrate these uncommon behaviors.The results obtained give full support to the above qualitative interpretation.Despite the strong influences of reaction kinetics and thermodynamic properties of the reacting mixtures,the totally reboiled reactive distillation columns are generally considered to present such unique behaviors and require tight inventory control of bottom reboiler to facilitate their control system development.
文摘To make magnetic separator more excellent in beneficiation, an advanced automatic control system for magnetic separator was designed. This paper designs automatic control system for magnetic separators, combination with PLC and technology of vary frequency. This system can wholly supervise and control the parameters of work course of magnetic separators.
基金supported by the National Natural Science Foundation of China (Grant Nos.10932005,10972120 and 11102098)the China Postdoctoral Science Foundation (Grant No.2011M500301)
文摘Flow separation in a conical diffuser with large divergence angle (29.14°) and large area ratio (3.533) is eliminated by a novel passive flow control device called Karman-Vortex Generator (KVG). The effect of the KVG is verified and investigated by the URANS, DES and DDES methods based on the SST model. CFD results show that the performance coefficient of the diffuser can be doubled by the KVG, and the total pressure recovery coefficient can be improved by about 1.2%. DES and DDES re- suits show that the KVG can introduce a Karman-vortex street frequency in the diffuser. This frequency decays rapidly, and could not be detected in the ending plane of the expansion section, Different KVG configurations with different locations and dimensions are numerically simulated and compared. Some suggestions are provided.