Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level ...Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level controlling, influence factors on the drum level sloshing were investigated. Firstly, drum sub-modules were developed using the method of modularization modeling, and then the model of drum level sloshing was set up as well. Experiments were carried out on the experimental rig, and the model was validated using the obtained experimental results. Dynamic simulation was made based on the model to get a 3-D graph of drum level sloshing, which shows a vivid procedure of drum level sloshing. The effect of feed-water flow rate, main-steam flow rate and heating quantity on the drum level sloshing was analyzed. The simulation results indicate that the signals with frequency higher than 0.05 Hz are that of drum level sloshing, the signals with frequency of 0.0-0.05 Hz are that of drum level trendy and "false water level", and variation of the feed-water flow rates, main-steam flow rates and heating quantities can change the frequency of drum level sloshing, i.e., the frequency of sloshing increases with the increase of feed-water flow rate, or the decrease of the main-steam flow rate and the heating quantity. This research work is fundamental to improve signal-to-noise ratio of drum level signal and precise controlling of drum level.展开更多
For the purpose of enhancing automobile safety and the effectiveness of recalls,increasing manufacturers' quality control capabilities,and reducing defects,we investigated thestatus of recalls over the last five y...For the purpose of enhancing automobile safety and the effectiveness of recalls,increasing manufacturers' quality control capabilities,and reducing defects,we investigated thestatus of recalls over the last five years.We have examined patterns and trends in motor vehiclesafety recalls using databases from China,Europe and the United States.A recall rate parameterwas developed to evaluate the level of recall enforcement based on analyzing the reasonsfor recalls and manufactures' characteristics.Moreover,there were substantial differencesin the recall rates of China compared with those in other countries,indicating that Chinese manufacturersneed to take more active action in recall.展开更多
基金Project(51276023) supported by the National Natural Science Foundation of ChinaProject(09k069) supported by the Open Project Funded by Universities Innovation Platform, Hunan Province, ChinaProject(2011GK311) supported by the Office of Science and Technology of Hunan Province, China
文摘Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level controlling, influence factors on the drum level sloshing were investigated. Firstly, drum sub-modules were developed using the method of modularization modeling, and then the model of drum level sloshing was set up as well. Experiments were carried out on the experimental rig, and the model was validated using the obtained experimental results. Dynamic simulation was made based on the model to get a 3-D graph of drum level sloshing, which shows a vivid procedure of drum level sloshing. The effect of feed-water flow rate, main-steam flow rate and heating quantity on the drum level sloshing was analyzed. The simulation results indicate that the signals with frequency higher than 0.05 Hz are that of drum level sloshing, the signals with frequency of 0.0-0.05 Hz are that of drum level trendy and "false water level", and variation of the feed-water flow rates, main-steam flow rates and heating quantities can change the frequency of drum level sloshing, i.e., the frequency of sloshing increases with the increase of feed-water flow rate, or the decrease of the main-steam flow rate and the heating quantity. This research work is fundamental to improve signal-to-noise ratio of drum level signal and precise controlling of drum level.
文摘For the purpose of enhancing automobile safety and the effectiveness of recalls,increasing manufacturers' quality control capabilities,and reducing defects,we investigated thestatus of recalls over the last five years.We have examined patterns and trends in motor vehiclesafety recalls using databases from China,Europe and the United States.A recall rate parameterwas developed to evaluate the level of recall enforcement based on analyzing the reasonsfor recalls and manufactures' characteristics.Moreover,there were substantial differencesin the recall rates of China compared with those in other countries,indicating that Chinese manufacturersneed to take more active action in recall.