针对静止无功补偿器(static var compensator,SVC)对双馈风电场次同步振荡(sub-synchronous oscillation,SSO)影响的问题,设计了抑制振荡策略。首先从阻尼转矩出发,分析SVC对双馈风电场SSO的抑制机理并设计抑制风电场SSO的附加阻尼器控...针对静止无功补偿器(static var compensator,SVC)对双馈风电场次同步振荡(sub-synchronous oscillation,SSO)影响的问题,设计了抑制振荡策略。首先从阻尼转矩出发,分析SVC对双馈风电场SSO的抑制机理并设计抑制风电场SSO的附加阻尼器控制策略;其次基于PSCAD/EMTDC平台,仿真分析SVC控制方式、并网位置以及容量对双馈风电场SSO的影响;最后采用遗传算法对附加阻尼器控制参数进行优化。算例结果表明所设计的附加阻尼器控制,既能满足SVC在正常时维持电压水平的作用,还能在发生SSO时对其进行有效抑制。展开更多
A semi-active force tracking PI controller is formulated and analyzed for a magnetorheological (MR) fluid-based damper in conjunction with a quarter-vehicle model. Two different models of the MR-damper are integrated ...A semi-active force tracking PI controller is formulated and analyzed for a magnetorheological (MR) fluid-based damper in conjunction with a quarter-vehicle model. Two different models of the MR-damper are integrated into the closed-loop system model, which includes: a model based upon the mean force-velocity (f-v) behaviour; and a model synthesis comprising inherent nonsmooth hysteretic force and the force limiting properties of the MR damper. The vehicle models are analyzed to study the vibration attenuation performance of the MR-damper using the semi-active force tracking PI control algorithm. The simulation results are also presented to demonstrate the influence of the damper nonlinearity, specifically the hysteresis, on the suspension performance. The results show that the proposed control strategy can yield superior vibration attenuation performance of the vehicle suspension actuated by the controllable MR-damper not only in the sprung mass resonance and the ride zones, but also in the vicinity of the wheel-hop. The results further show that the presence of damper hystersis deteriorates the suspension performance.展开更多
Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system...Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.展开更多
Magnetorheological (MR) dampers have been proposed to control the vibration of offshore platforms in this paper. The semi-active control strategy based on fuzzy control algorithm was adopted to determine the optimal...Magnetorheological (MR) dampers have been proposed to control the vibration of offshore platforms in this paper. The semi-active control strategy based on fuzzy control algorithm was adopted to determine the optimal output control force based on the responses of jacket platforms. A typical jacket platform in Mexico Gulf was selected as the numerical example to investigate the effectiveness of the proposed control method. Furthermore, a model experiment was performed to validate the results of the numerical simulation. The experimental model of the jacket platform was designed based on dynamical similarity criterion by the scale of 1:50. Both of the numerical and experimental results show that the semi-active control system with the MR damper can reduce vibrations of jacket platforms effectively and at the same time the control effect is stable.展开更多
Wide area damping controller(WADC) is usually utilized to damp interarea low frequency oscillation in power system. However, conventional WADC design method neglects the influence of signal transmission delay and damp...Wide area damping controller(WADC) is usually utilized to damp interarea low frequency oscillation in power system. However, conventional WADC design method neglects the influence of signal transmission delay and damping performance of WADC designed by the conventional method may deteriorate or even has no effect when signal transmission delay is beyond delay margin, an index that denotes delay endurance degree of power system. Therefore, a new design method for WADC under the condition of expected damping factor and required signal transmission delay is presented in this work. An improved delay margin with less conservatism is derived by adopting a new Lyapunov-Krasovskii function and more compact bounding technique on the derivative of Lyapunov-Krasovskii functional. The improved delay margin, which constructs the correlation of damping factor and signal transmission delay, can be used to design WADC. WADC designed by the proposed method can ensure that power system satisfies expected damping factor when WADC input signal is delayed within delay margin. Satisfactory test results demonstrate the effectiveness of the proposed method.展开更多
文摘针对静止无功补偿器(static var compensator,SVC)对双馈风电场次同步振荡(sub-synchronous oscillation,SSO)影响的问题,设计了抑制振荡策略。首先从阻尼转矩出发,分析SVC对双馈风电场SSO的抑制机理并设计抑制风电场SSO的附加阻尼器控制策略;其次基于PSCAD/EMTDC平台,仿真分析SVC控制方式、并网位置以及容量对双馈风电场SSO的影响;最后采用遗传算法对附加阻尼器控制参数进行优化。算例结果表明所设计的附加阻尼器控制,既能满足SVC在正常时维持电压水平的作用,还能在发生SSO时对其进行有效抑制。
文摘A semi-active force tracking PI controller is formulated and analyzed for a magnetorheological (MR) fluid-based damper in conjunction with a quarter-vehicle model. Two different models of the MR-damper are integrated into the closed-loop system model, which includes: a model based upon the mean force-velocity (f-v) behaviour; and a model synthesis comprising inherent nonsmooth hysteretic force and the force limiting properties of the MR damper. The vehicle models are analyzed to study the vibration attenuation performance of the MR-damper using the semi-active force tracking PI control algorithm. The simulation results are also presented to demonstrate the influence of the damper nonlinearity, specifically the hysteresis, on the suspension performance. The results show that the proposed control strategy can yield superior vibration attenuation performance of the vehicle suspension actuated by the controllable MR-damper not only in the sprung mass resonance and the ride zones, but also in the vicinity of the wheel-hop. The results further show that the presence of damper hystersis deteriorates the suspension performance.
文摘Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.
基金Supported by the National Natural Science Foundation of China (NSFC-5060900).
文摘Magnetorheological (MR) dampers have been proposed to control the vibration of offshore platforms in this paper. The semi-active control strategy based on fuzzy control algorithm was adopted to determine the optimal output control force based on the responses of jacket platforms. A typical jacket platform in Mexico Gulf was selected as the numerical example to investigate the effectiveness of the proposed control method. Furthermore, a model experiment was performed to validate the results of the numerical simulation. The experimental model of the jacket platform was designed based on dynamical similarity criterion by the scale of 1:50. Both of the numerical and experimental results show that the semi-active control system with the MR damper can reduce vibrations of jacket platforms effectively and at the same time the control effect is stable.
基金Project(51007042) supported by the National Natural Science Foundation of China
文摘Wide area damping controller(WADC) is usually utilized to damp interarea low frequency oscillation in power system. However, conventional WADC design method neglects the influence of signal transmission delay and damping performance of WADC designed by the conventional method may deteriorate or even has no effect when signal transmission delay is beyond delay margin, an index that denotes delay endurance degree of power system. Therefore, a new design method for WADC under the condition of expected damping factor and required signal transmission delay is presented in this work. An improved delay margin with less conservatism is derived by adopting a new Lyapunov-Krasovskii function and more compact bounding technique on the derivative of Lyapunov-Krasovskii functional. The improved delay margin, which constructs the correlation of damping factor and signal transmission delay, can be used to design WADC. WADC designed by the proposed method can ensure that power system satisfies expected damping factor when WADC input signal is delayed within delay margin. Satisfactory test results demonstrate the effectiveness of the proposed method.