This paper probes into the feasibility of equilibrating pressure of water distribution network through (using auto-control valves) in theory and in the economy. An optimal valve control model is designed to minimize t...This paper probes into the feasibility of equilibrating pressure of water distribution network through (using auto-control valves) in theory and in the economy. An optimal valve control model is designed to minimize the sum of squares of residual pressure in the network. Such an analog simulation has been performed on the year 2003 programming network of a certain littoral district in North China, through which this paper confirms that it is feasible to equilibrate pressure with auto-control valves in theory. The research work has brought about a discovery of applicable conditions of valves in economic feasibility, which avoids a great economic loss due to the wild use of auto-control valve. In addition, simulated annealing algorithm is applied to optimize valve settings and shown to identify global optimum or near-optimum.展开更多
Cavitation flows induced around an axial-flow pump blade and inside a high pressure cage-type valve are simulated by a two-dimensional unsteady Navier-Stokes analysis with the simplest treatment of bubble dynamics. Th...Cavitation flows induced around an axial-flow pump blade and inside a high pressure cage-type valve are simulated by a two-dimensional unsteady Navier-Stokes analysis with the simplest treatment of bubble dynamics. The fluid is assumed as a continuum of homogeneous dispersed mixture of water and vapor nuclei. The analysis is aimed to capture transient stages with high amplitude pressure change during the birth and collapse of the bubble especially at the stage of cavitation inception. By the pump blade analysis, in which the field pressure is moderate, cavitation number of the inception and locations of developed cavitation are found to agree with experimental results in a wide flow range between high incidence and negative incidence. In the valve flow analysis, in which the water pressure of 5MPa is reduced to 2MPa, pressure change responding to the bubble collapse between the vapor pressure lower than 1 KPa and the extreme pressure of higher than 104 KPa is captured through a stable computation. Location of the inception bubble and pressure force to the valve plug is found agree well with the respective experimental features.展开更多
文摘This paper probes into the feasibility of equilibrating pressure of water distribution network through (using auto-control valves) in theory and in the economy. An optimal valve control model is designed to minimize the sum of squares of residual pressure in the network. Such an analog simulation has been performed on the year 2003 programming network of a certain littoral district in North China, through which this paper confirms that it is feasible to equilibrate pressure with auto-control valves in theory. The research work has brought about a discovery of applicable conditions of valves in economic feasibility, which avoids a great economic loss due to the wild use of auto-control valve. In addition, simulated annealing algorithm is applied to optimize valve settings and shown to identify global optimum or near-optimum.
文摘Cavitation flows induced around an axial-flow pump blade and inside a high pressure cage-type valve are simulated by a two-dimensional unsteady Navier-Stokes analysis with the simplest treatment of bubble dynamics. The fluid is assumed as a continuum of homogeneous dispersed mixture of water and vapor nuclei. The analysis is aimed to capture transient stages with high amplitude pressure change during the birth and collapse of the bubble especially at the stage of cavitation inception. By the pump blade analysis, in which the field pressure is moderate, cavitation number of the inception and locations of developed cavitation are found to agree with experimental results in a wide flow range between high incidence and negative incidence. In the valve flow analysis, in which the water pressure of 5MPa is reduced to 2MPa, pressure change responding to the bubble collapse between the vapor pressure lower than 1 KPa and the extreme pressure of higher than 104 KPa is captured through a stable computation. Location of the inception bubble and pressure force to the valve plug is found agree well with the respective experimental features.