棒束通道温度场可视化实验研究 被引量:5
1
作者 米争鹏 谭思超 +2 位作者 李兴 黄云龙 王啸宇 《原子能科学技术》 EI CAS CSCD 北大核心 2018年第5期847-854,共8页
基于激光诱导荧光技术,对带定位格架棒束通道的温度场进行了可视化实验研究。采用折射率匹配技术,搭建可视化实验系统,提出适用于棒束通道温度场点对点标定的关系式,利用此关系式对定位格架下游温度场进行了重构。实验结果显示,采用激... 基于激光诱导荧光技术,对带定位格架棒束通道的温度场进行了可视化实验研究。采用折射率匹配技术,搭建可视化实验系统,提出适用于棒束通道温度场点对点标定的关系式,利用此关系式对定位格架下游温度场进行了重构。实验结果显示,采用激光诱导荧光技术可获得定位格架下游全场温度分布。分析了不同加热形式、流量和热流密度对温度分布的影响,并采用轴向流体温差和温度分布不均匀性定量评价了定位格架下游的搅混能力。在定位格架下游0~4 Dh范围内,搅混性能逐渐增大,在4 Dh后会随高度的增加逐渐减小。结果表明,激光诱导荧光技术可适用于棒束通道温度场的非介入式、全场测量,有助于对相应程序的验证和定位格架搅混性能的评价。 展开更多
关键词 棒束 激光诱导荧光技术 温度分布 可视化 搅混性能
下载PDF
Effects of Slow-Mixing on the Coagulation Performance of Polyaluminum Chloride (PACI) 被引量:3
2
作者 张忠国 刘丹 +4 位作者 胡丹丹 李多 任晓晶 程言君 栾兆坤 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第3期318-323,共6页
Conventional jar tests and on-line size monitoring were used to investigate the effects of slow-mixing intensity and duration on residual turbidity and floc size during charge neutralization coagulation and sweep floc... Conventional jar tests and on-line size monitoring were used to investigate the effects of slow-mixing intensity and duration on residual turbidity and floc size during charge neutralization coagulation and sweep floc- culation with polyaluminum chloride. The compensatory effect of slow-mixing on coagulation performance fol- low!ng inadequate_or excessive rapid-mi_xing was also examined. It is found that slowTmixing intensity has a more marked positive ettect on charge neutralization coas;ulatlon tlaan on sweep tlocculatlon. llle optimal root-mean- square velocity gradient, G, for slow-mixing is 15 s-' for both coagulation mechanisms, and charge neutralization coagulation requires a longer slow-mixing duration. The optimal slow-mixing duration, based on residual turbidity,is longer than the time to tbrm the largest mean Ilocs. The optimal product of G and mixing duration, GT, lbr slow-mixing during charge neutralization coagulation (13500) are higher than that during sweep flocculation (4500) and both are less than the range of values recommended by the American Water Works Association (24000-84000).The optimal GT value under various slow-mixing conditions increases with G. Appropriate extension'of slow-mixing duration during charge neutralization coagulation can improve coagulation performance after an inadequate or excessive rapid-mixing duration, but during sweep flocculation, appropriate shortening of slow-mixing duration after an excessive rapid-mixing or appropriate extension of slow-mixing duration after an inadequate rapid-mixing is favorable. 展开更多
关键词 slow-mixing polyaluminum chloride charge neutralization coagulation -sweep-flocculati-on GT value
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部