In order to solve fretting instability problem of gear shaft shoulder due to torsional vibration in mechanical system, the mathematical model of fretting instability vibration of gear shaft shoulder was established by...In order to solve fretting instability problem of gear shaft shoulder due to torsional vibration in mechanical system, the mathematical model of fretting instability vibration of gear shaft shoulder was established by adopting the method of combining kinematics and tribology, and the numerical analysis was applied to the fretting instability mechanism of gear shaft shoulder by introducing the friction instability damping ratio. The numerical results show that the main factors causing the unstable and vibrating gear shaft shoulder are the large tightening torque and too large static friction coefficient. The reasonable values of the static friction coefficient, the amount of interference and tightening torque can effectively mitigate the fretting instability phenomenon of gear shaft shoulder. The experimental results verify that damping plays a significant role in eliminating the vibration of gear shaft control system.展开更多
基金Project(2008AA11A116)supported by the National High Technology Research and Development Program of ChinaProject(9140A2011QT4801)supported by advanced research of the Weapon Equipment Key Fund Program,ChinaProject(61075002)supported by the Independent Subject of State Key Laboratory of Advanced Design and Manufacturing for Vehicle Body of Hunan University,China
文摘In order to solve fretting instability problem of gear shaft shoulder due to torsional vibration in mechanical system, the mathematical model of fretting instability vibration of gear shaft shoulder was established by adopting the method of combining kinematics and tribology, and the numerical analysis was applied to the fretting instability mechanism of gear shaft shoulder by introducing the friction instability damping ratio. The numerical results show that the main factors causing the unstable and vibrating gear shaft shoulder are the large tightening torque and too large static friction coefficient. The reasonable values of the static friction coefficient, the amount of interference and tightening torque can effectively mitigate the fretting instability phenomenon of gear shaft shoulder. The experimental results verify that damping plays a significant role in eliminating the vibration of gear shaft control system.