期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
除氧器收能装置在干熄焦的应用
1
作者 徐瑞阳 《燃料与化工》 2015年第5期30-31,共2页
介绍了除氧器乏汽回收的方式及装置,应用膜式凝结器回收装置进行乏汽热量回收和冷凝水回收,实现了热量的循环利用,节约了低压蒸汽用量,经济效益可观。
关键词 干熄焦 除氧器 收能装置 乏汽回
下载PDF
Contrastive analysis and crashworthiness optimization of two composite thin-walled structures 被引量:4
2
作者 谢素超 周辉 +1 位作者 梁习锋 任鑫 《Journal of Central South University》 SCIE EI CAS 2014年第11期4386-4394,共9页
For the safety protection of passengers when train crashes occur, special structures are crucially needed as a kind of indispensable energy absorbing device. With the help of the structures, crash kinetic-energy can b... For the safety protection of passengers when train crashes occur, special structures are crucially needed as a kind of indispensable energy absorbing device. With the help of the structures, crash kinetic-energy can be completely absorbed or dissipated for the aim of safety. Two composite structures(circumscribed circle structure and inscribed circle structure) were constructed. In addition, comparison and optimization of the crashworthy characteristic of the two structures were carried out based on the method of explicit finite element analysis(FEA) and Kriging surrogate model. According to the result of Kriging surrogate model, conclusions can be safely drawn that the specific energy absorption(SEA) and ratio of specific energy absorption to initial peak force(REAF) of circumscribed circle structure are lager than those of inscribed circle structure under the same design parameters. In other words, circumscribed circle structure has better performances with higher energy-absorbing ability and lower initial peak force. Besides, error analysis was adopted and the result of which indicates that the Kriging surrogate model has high nonlinear fitting precision. What is more, the SEA and REAF optimum values of the two structures have been obtained through analysis, and the crushing results have been illustrated when the two structures reach optimum SEA and REAF. 展开更多
关键词 contrastive analysis crashworthiness optimization composite structure Kriging surrogate model finite element analysis
下载PDF
Theoretical Investigation on Internal Leakage and Its Effect on the Efficiency of Fluid Switcher-Energy Recovery Device for Reverse Osmosis Desalting Plant 被引量:2
3
作者 乞炳蔚 王越 +3 位作者 王照成 张燕平 徐世昌 王世昌 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第11期1216-1223,共8页
This work is focused on the theoretical investigation of internal leakage of a newly developed pi lotscale fluid switcherenergy recovery device (FSERD) for reverse osmosis (RO) system. For the purpose of in creasi... This work is focused on the theoretical investigation of internal leakage of a newly developed pi lotscale fluid switcherenergy recovery device (FSERD) for reverse osmosis (RO) system. For the purpose of in creasing FSERD efficiency and reducing the operating cost of RO, it is required to control the internal leakage in a low level. In this work, the internal leakage rates at different leakage gaps and retentate brine pressures are investigated by computational fluid dynamics (CFD) method and validating experiments. It is found that the internal leak age has a linear relationship with the retentate brine pressure and a polynomial relationship with the scale of leakage gap. The results of the present work imply that low internal leakage and high retentate brine pressure bring benefits to achieve high FSRD efficiency. 展开更多
关键词 internal leakage rate fluid switcher-energy recovery device computational fluid dynamics energytransfer efficiency
下载PDF
Theoretical and Experimental Study of a Cylindro-Parabolic Solar Collector
4
作者 Y. Boukhchana A. Fellah A. Ben Brahim 《Journal of Environmental Science and Engineering》 2011年第8期1026-1030,共5页
This article outlines the theoretical and experimental performance studies of a cylindro-parabolic solar collector. The theoretical study consists on the establishment, through mass and energy balances, of a mathemati... This article outlines the theoretical and experimental performance studies of a cylindro-parabolic solar collector. The theoretical study consists on the establishment, through mass and energy balances, of a mathematical model to control the exiting temperature of the heating fluid as well as the temperatures of the absorber and the glass. The experimental level investigates the influence of the solar absorber tube diameter on the performances of the driving device. Several experiments were made in order to know the possibility to reach temperatures being able to ensure for example the ammonia vaporization in the generator of a solar absorption refrigeration system. These experiments were carried out under various operating and climatic conditions. The results are presented and discussed. 展开更多
关键词 Solar energy EXPERIMENTATION absorption refrigeration solar collector.
下载PDF
An Energy and Exergy Analysis of a Microturbine CHP System
5
作者 B.M.A. Makhdoum B. Agnew 《Journal of Environmental Science and Engineering》 2011年第4期508-518,共11页
The micro-turbine is known as a producer of high-grade energy (work) and also low energy (heat). The following low grade heat energy have been modeled under ISO ambient conditions (international standard organiza... The micro-turbine is known as a producer of high-grade energy (work) and also low energy (heat). The following low grade heat energy have been modeled under ISO ambient conditions (international standard organization), i.e. 15 ℃ and 1 bar, to utilize the waste heat energy of a 200 kW micro-turbine combined with a single effect absorption chiller, an organic ranking cycle using R245fa (ORC-R245 fa) as a working fluid, a multi-effect distillation desalination (MED) and a thermal vapor compression MED Desalination unit (TVC-MED). The thermal comparison was carried out based on an energy and exergy analysis in terms of electric efficiency, exergetic efficiency, carbon footprint, and energy utilization factor (EUF). The software package IPSEpro has been used to model and simulate the proposed power plants. As a result, utilizing the exhaust waste heat energy in single-effect absorption chillier has contributed to stabilize ambient temperature fluctuation, and gain the best exergetic efficiency of 39%, while the EUF has reached 72% and the carbon footprint was reduced by 75% in MED and TVC-MED Desalination respectively. The results also reveal that TVC-MED is more efficient than traditional MED as its gain output ratio (GOR) is improved by 5.5%. In addition, ORC-245fa generates an additional 20% of the micro-turbine electricity generation. 展开更多
关键词 MICRO-TURBINE absorption chiller energy EXERGY ORC MED TVC-MED.
下载PDF
Analysis of noncommensurate sampling effects on the performance of PN code tracking loops 被引量:1
6
作者 YANG Jian YANG YiKang +2 位作者 LI JiSheng LI HengNian YANG TianShe 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2018年第6期893-905,共13页
Noncoherent early-late processing (NELP) code tracking loops are often implemented using digital hardware for digital global positioning system (GPS) receivers. Noncommensurate sampling technology is widely used b... Noncoherent early-late processing (NELP) code tracking loops are often implemented using digital hardware for digital global positioning system (GPS) receivers. Noncommensurate sampling technology is widely used because it is viewed as an effective solution to cope with the drawback of digital effects. However, the relationship between the sampling rate and auto-correlation function (ACF) is not adequately characterized by traditional analysis. The principles for selecting the sampling rate are still not apparent. In order to solve this problem, we first analyzed the effects of different sampling rates on ACF and obtained the analytical form of a discrete auto-correlation function (DACF) for a noncommensurate sampling rate. Based on the result, the relationship between the step variation in DACF and NELP parameters such as sampling rate, integration time, and correlator spacing was determined. The maximum step variation size of DACF was also determined. However, considering the actual situation, additional factors such as code Doppler shift, precorrelation filter, and thermal noise may degrade the step variation of DACE The relationship between the step variation and these factors was analyzed separately. An appropriate sampling rate and appropriate correlator spacing were proposed to achieve the typical accuracy of measurement. The numerical simulation verified the validity of the above theoretical analyses, and finally, the conclusions and design constraints for the digital GPS receiver are summarized. 展开更多
关键词 sampling rate code tracking loops heat dissipation GPS digital receiver
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部